Literature DB >> 30222818

The Correlation of Pars Plana Incision and Transient Hypotony After Silicone Oil Removal.

Xian Zhang, Bo Chen, Huajing Yang, Yinwei Song, Di Zhang, Brian T Soetikno, Xufang Sun.   

Abstract

BACKGROUND AND
OBJECTIVE: To evaluate the correlation between pars plana incision and transient hypotony after silicone oil removal in aphakic eyes PATIENTS AND METHODS:Twenty-two patients with aphakia and a high degree of myopia with silicone oil tamponade were recruited for this prospective study and randomly scheduled to two groups for silicone oil removal: 3.5-mm corneal incision with suture corneal or 20-gauge pars plana incision with suture. Intraocular pressure (IOP) was measured and fundus and anterior structure were examined preoperatively on the first, third, and seventh postoperative day and at 1 month after surgery.
RESULTS: IOPs in the pars plana group were significantly lower than the corneal group on the first and third day after surgery (P < .001). Nine of the 11 patients in the pars plana group suffered ciliary detachment accompanied by hypotony (IOP < 8 mm Hg), among whom three patients exhibited excessive hypotony (IOP < 5 mm Hg), whereas the ciliary bodies remained tightly attached and IOP was normal in the corneal group. Among these nine patients, six eyes were observed to have multiple silicone oil granules in the supraciliary cavity, three exhibited gaps of pars plana below the scleral incision site, and two had vitreous hemorrhage. Hypotony spontaneously relieved at the seventh postoperative day for all patients.
CONCLUSION: Pars plana incision is the crucial cause of ciliary detachment and consequent transient hypotony after silicone oil removal. Using corneal limbus incision in patients with aphakic eyes to avoid the par plana incision is expected to reduce the incidence of hypotony with minimal complications. [Ophthalmic Surg Lasers Imaging Retina. 2018;49:e44-e51.]. Copyright 2018, SLACK Incorporated.

Entities:  

Mesh:

Substances:

Year:  2018        PMID: 30222818     DOI: 10.3928/23258160-20180907-06

Source DB:  PubMed          Journal:  Ophthalmic Surg Lasers Imaging Retina        ISSN: 2325-8160            Impact factor:   1.300


  2 in total

1.  Trocar opening: silicone oil removal with phacoemulsification and intraocular lens implantation.

Authors:  Xu Zhang; Ya-Jie Pan; Zheng-Yu Song
Journal:  Int J Ophthalmol       Date:  2019-11-18       Impact factor: 1.779

2.  Accuracy of segmented measurement of axial length in ultra-high myopia filled with silicone oil using immersion B-scan ultrasonography.

Authors:  Qing-Hua Yang; Hong-Tao Zhang; Xiao-Qi Li; Bing Chen; Zhao-Hui Li; Yi-Fei Huang; Xin Jin; Ying Zhang; Li-Qiang Wang
Journal:  Int J Ophthalmol       Date:  2022-05-18       Impact factor: 1.645

  2 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.