Gentamicin drug monitoring for peritonitis patients by using a CMOS-BioMEMS-based microcantilever sensor.

Kuan-Wei Li1, Yi-Kuang Yen2.   

Abstract

We developed a Complementary Metal-Oxide-Semiconductor Bio-Microelectromechanical Systems (CMOS-BioMEMS) based piezoresistive microcantilever sensor for detecting gentamicin, a peritonitis therapeutic small-molecule drug. In recent years, the patient-centric concept has been emphasized. In such a trend, therapeutic drug monitoring (TDM) is especially crucial for patients with peritonitis to avoid adverse reactions from a high concentration of gentamicin in the blood. With the aid of a commercialized semiconductor manufacturing process, the microcantilever sensing platform can serve as a portable, low-cost device and offer real-time detection. With chemical surface modification and capture antibody immobilization, the sensor can detect the small-molecule (< 2 kDa) gentamicin directly. We also modified the pH value of the buffer solution and applied an external electric field to promote sensor sensitivity. Comparing the change of the signals in a non-electric field of antibody immobilization and a 60-volt electric field of antibody immobilization showed that the average signal response increased 1.8 times. In the detection of gentamicin with different concentrations of 10-200 μg/mL, the limit of detection (LOD) of the sensor was 9.44 µg/mL. Finally, the detecting result of a microrcantilever sensor was compared with the one measured by a common instrument in hospital, and the high correlation was expressed between them in gentamicin detection. The CMOS-BioMEMS-based piezoresistive microcantilever sensor has been demonstrated to have great potential as a point-of-care (POC) device for real-time drug concentration monitoring.
Copyright © 2018 Elsevier B.V. All rights reserved.

Entities:  

Keywords:  Electric field; Gentamicin; Low-cost package; Microcantilever; Miniaturization sample

Mesh:

Substances:

Year:  2018        PMID: 30220446     DOI: 10.1016/j.bios.2018.09.014

Source DB:  PubMed          Journal:  Biosens Bioelectron        ISSN: 0956-5663            Impact factor:   10.618


  3 in total

1.  A Low-Power CMOS Microfluidic Pump Based on Travelling-Wave Electroosmosis for Diluted Serum Pumping.

Authors:  Pei-Wen Yen; Shiang-Chi Lin; Yi-Chun Huang; Yu-Jie Huang; Yi-Chung Tung; Shey-Shi Lu; Chih-Ting Lin
Journal:  Sci Rep       Date:  2019-10-15       Impact factor: 4.379

2.  A Flexible PI/Si/SiO2 Piezoresistive Microcantilever for Trace-Level Detection of Aflatoxin B1.

Authors:  Yuan Tian; Yi Liu; Yang Wang; Jia Xu; Xiaomei Yu
Journal:  Sensors (Basel)       Date:  2021-02-05       Impact factor: 3.576

3.  A V-Shaped Microcantilever Sensor Based on a Gap Method for Real-Time Detection of E. coli Bacteria.

Authors:  Jino Fathy; Yongjun Lai
Journal:  Biosensors (Basel)       Date:  2022-03-25
  3 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.