PURPOSE: To evaluate intraoperative anterior chamber depth (ACD) measurements of the aphakic eye to predict the postoperative ACD and compare 2 intraocular lens (IOL) designs.
SETTING: Hanusch Hospital, Vienna, Austria.
DESIGN: Prospective study.
METHODS: In this prospective study, patients scheduled for cataract surgery received a plate-haptic IOL (Asphina, Carl Zeiss Meditec AG) or an open-loop haptic IOL (ZCB00, Johnson & Johnson). Preoperatively, optical biometry (IOLMaster 700, CZM, or Lenstar, Haag-Streit) was performed. Intraoperatively, a prototype setup was used to perform time-domain OCT scans of the anterior eye segment (Visante connected to OPMI Lumera 200, both CZM). The intraoperative ACD was measured and used to predict the postoperative IOL position. Optical biometry and subjective refraction and autorefraction (RM 8800, Topcon) were performed 2 months postoperatively.
RESULTS: The study comprised 203 eyes of 203 patients. A partial least-square regression model for ACD generated 2 months postoperatively showed that the predictive power of the intraoperative ACD (0.48) was highest followed by the axial eye length (0.45) and then the preoperatively measured ACD (0.30). These findings were confirmed in a bootstrapping model. Regression models combining the preoperative ACD and intraoperative ACD resulted in further significant improvement.
CONCLUSIONS: Intraoperative ACD measurements predicted the postoperative position of open-loop IOLs and plate-haptic IOLs better than preoperative ACD measurements. Combining preoperative and intraoperative ACD measurements further improved the prediction.
Copyright © 2018. Published by Elsevier Inc.

Entities:  

Mesh:

Year:  2018        PMID: 30219261     DOI: 10.1016/j.jcrs.2018.07.044

Source DB:  PubMed          Journal:  J Cataract Refract Surg        ISSN: 0886-3350            Impact factor:   3.351


  5 in total

Review 1.  Intraocular lens optic edge design for the prevention of posterior capsule opacification after cataract surgery.

Authors:  Sophie Maedel; Jennifer R Evans; Annette Harrer-Seely; Oliver Findl
Journal:  Cochrane Database Syst Rev       Date:  2021-08-16

2.  Intraoperative optical coherence tomography guided corneal sweeping for removal of remnant Interface fluid during ultra-thin Descemet stripping automated endothelial keratoplasty.

Authors:  Michael Mimouni; Martin Kronschläger; Manuel Ruiss; Oliver Findl
Journal:  BMC Ophthalmol       Date:  2021-04-15       Impact factor: 2.209

3.  Quantitative Analysis of Gap Between the Intraocular Lens and Posterior Capsule Using Microscope-Integrated Optical Coherence Tomography in Eyes Undergoing Phacoemulsification.

Authors:  Ritu Nagpal; Chetan Shakkarwal; Rinky Agarwal; Rahul Kumar Bafna; Prafulla Kumar Maharana; Namrata Sharma
Journal:  Clin Ophthalmol       Date:  2021-05-10

Review 4.  The Development and Clinical Application of Innovative Optical Ophthalmic Imaging Techniques.

Authors:  Palaiologos Alexopoulos; Chisom Madu; Gadi Wollstein; Joel S Schuman
Journal:  Front Med (Lausanne)       Date:  2022-06-30

Review 5.  Clinical applications for intraoperative optical coherence tomography: a systematic review.

Authors:  Marc B Muijzer; Peter A W J Schellekens; Henny J M Beckers; Joke H de Boer; Saskia M Imhof; Robert P L Wisse
Journal:  Eye (Lond)       Date:  2021-07-16       Impact factor: 3.775

  5 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.