Karin Allard1, Madeleine Zetterberg1,2.
Abstract
PURPOSE: To describe the results of phacoemulsification and implantation of toric intraocular lenses (IOLs) in patients with cataract and keratoconus. PATIENTS AND METHODS: Prospective study of 4 patients (4 eyes) with cataract and keratoconus who underwent phacoemulsification with implantation of a toric IOL. Two different toric IOLs were used: AcrySof IQ SN6AT9 and AT Torbi 709M(P). Corneal tomography was performed preoperatively using Scheimpflug technique with Pentacam. Astigmatism was regular or slightly irregular in all patients. Postoperatively, best-corrected visual acuity (BCVA), astigmatism, spherical equivalent, and complications were recorded for all patients. Follow-up time was between 4 weeks and 7 months.Entities:
Keywords: astigmatism; cataract; keratoconus; phacoemulsification; toric intraocular lens
Year: 2018 PMID: 30214320 PMCID: PMC6118281 DOI: 10.2147/IMCRJ.S174315
Source DB: PubMed Journal: Int Med Case Rep J ISSN: 1179-142X
Demographics and clinical characteristics at baseline
| Patient 1 | Patient 2 | Patient 3 | Patient 4 | |
|---|---|---|---|---|
| Sex | Female | Male | Male | Male |
| Eye | Right | Left | Left | Right |
| Age (years) | 90 | 67 | 56 | 66 |
| BCVA | 20/50 | 20/63 | 20/40 | Hand motion |
| Axial length (mm) | 21.58 | 25.14 | 26.84 | 24.25 |
| Autorefractor sphere (D) | +4.37 | +1.87 | No target | No target |
| Autorefractor cylinder (D) | −6.12 | −4.62 | No target | No target |
| Autorefractor SE (D) | +1.31 | −0.44 | No target | No target |
| +51.4 | +47.9 | +49.3 | +55.8 | |
| Final D value | 5.98 | 3.81 | 12.35 | 16.55 |
| Steepest | +50.9 | +49.13 | ||
| IOLMaster (D) | ||||
| IOL | AcrySof IQ toric SN6AT9 | AcrySof IQ toric SN6AT9 | AT Torbi 709 M(P) | AT Torbi 709 M(P) |
| IOL power (D) | +23.5 | +15.5 | +4 sphere, +12 cylinder | +1 sphere, +7.5 cylinder |
| Target refraction (D) | +0.3 | −2.67 | −0.11 | +1.5 |
Notes:
Steepest K-value from Pentacam.
Belin/Ambrosio Enhanced Ectasia Display from Pentacam.
No data recorded.
Abbreviations: BCVA, best-corrected visual acuity; SE, spherical equivalent; IOL, intraocular lens.
Visual and astigmatism (cylinder according to autorefractor) outcomes
| Patient 1 | Patient 2 | Patient 3 | Patient 4 | |
|---|---|---|---|---|
| BCVA | ||||
| Preoperative | 20/50 | 20/63 | 20/40 | Hand motion |
| Day 1–7 | 20/50 | 20/25 | 20/63 | 20/200 |
| Week 4 | 20/40 | 20/32 | 20/63 | 20/63 |
| Month 5–7 | 20/20 | 20/32 | ||
| Autorefractor cylinder (D) | ||||
| Preoperative | −6.12 | −4.62 | No target | No target |
| Day 1–7 | −3.75 | −1.5 | −2.0 | ±0.0 (subjective refraction) |
| Week 4 | −1.5 (subjective refraction) | −1.5 | −2.0 | −2.75 |
| Month 5–7 | −1.75 | −3.0 | ||
| Autorefractor SE (D) | ||||
| Preoperative | +1.31 | −0.44 | No target | No target |
| Day 1–7 | +0.125 | −2.0 | +0.5 | +1.5 (subjective refraction) |
| Week 4 | −0.75 (subjective refraction) | −2.5 | ±0.0 | −2.125 |
| Month 5–7 | −2.4 | +0.25 | ||
| Target refraction (D) | +0.3 | −2.67 | −0.11 | +1.5 |
| BPE | −0.18 D (at 1 week) | +0.30 D (at 7 months) | +0.36 (at 3 months) | −3.63 D (at 4 weeks) |
Notes:
No follow-up.
The difference between target refraction and the spherical equivalent of the final refraction.
Abbreviations: BCVA, best-corrected visual acuity; SE, spherical equivalent; BPE, biometry prediction error.
Figure 1Scheimpflug imaging (Pentacam, Oculus) of the corneal front surface in patient 1.
Figure 2Scheimpflug imaging (Pentacam, Oculus) of the corneal front surface in patient 2.
Figure 3Scheimpflug imaging (Pentacam, Oculus) of the corneal front surface in patient 3.
Figure 4Scheimpflug imaging (Pentacam, Oculus) of the corneal front surface in patient 4.