Application of contrast-enhanced ultrasound for evaluation of thyroid nodules.

Jia Zhan1,2, Hong Ding1.   

Abstract

Contrast-enhanced ultrasound (CEUS) is widely used to evaluate tumor microcirculation, which is useful in the differential diagnosis between benignity and malignancy. In the last 10 years, the applicability of CEUS to thyroid nodules has greatly improved due to technological refinements and the development of second-generation contrast agents. In this review, we summarize the applications of CEUS for thyroid nodules, focusing on the imaging findings of malignant and benign nodules in the existing literature and the use of those findings to predict malignancies, with an additional brief description of the utilization of CEUS for other thyroid-related diseases.

Entities:  

Keywords:  Contrast media; Diagnosis; Elasticity imaging techniques; Thyroid nodule; Ultrasonography

Year:  2018        PMID: 30213158      PMCID: PMC6177690          DOI: 10.14366/usg.18019

Source DB:  PubMed          Journal:  Ultrasonography        ISSN: 2288-5919


Introduction

Contrast-enhanced ultrasound (CEUS) is considered to be an effective technique to evaluate microvascularization, which is important because angiogenesis is the basis for neoplastic growth [1]. CEUS parameters aid in characterizing lesions and evaluating tumor angiogenesis [2]. CEUS was first used in the diagnostic work-up of focal liver lesions, and international ultrasonography guidelines recommend CEUS as the method of choice for focal liver lesions if B-mode and Doppler ultrasonography (US) are inconclusive [3]. As time passed, CEUS was additionally applied to the study of the kidneys [4], prostate, breasts [5], and testes [6]. Thyroid nodules are a common finding in the general population, and their detection rate is increasing with the widespread use of US. Most thyroid nodules are benign, and fewer than 5% are malignant [7]. In the last decade, the applicability of CEUS to thyroid-related disease greatly improved due to the development of more advanced US equipment and the introduction of second-generation contrast agents (SonoVue, Bracco Imaging, Milan, Italy) for the characterization of malignant thyroid nodules. SonoVue consists of sulfur hexafluoride microbubbles (2-10 μm); after configuration, it is injected intravenously as a small bolus when used for CEUS. The microbubbles stay in the circulation for a period of time [8], during which the ultrasound system is focused on the region of interest (ROI). When microbubbles in the blood flow past the imaging window, they reflect a unique echo that stands in contrast to the surrounding tissue due to the mismatch of multiple orders of magnitude between the echogenicity of the microbubbles and the tissue. The ultrasound device converts the patterns of strong echogenicity into a contrast-enhanced image of the ROI. In this way, the echo of the bloodstream is enhanced, permitting the dynamic detection of microvessels. The use of SonoVue in the thyroid gland was first reported by Bartolitta, who stated that malignant thyroid nodules measuring less than 1 cm in diameter mostly did not show vascularization, those between 1 and 2 cm in diameter showed faint dotted contrast enhancement, and nodules with a diameter larger than 2 cm presented diffuse contrast enhancement [9]. This pivotal finding demonstrated that malignant thyroid nodules had an enhancement pattern related to the size of the tumor. Since that report was published, CEUS has been widely performed for the differential diagnosis between benign and malignant thyroid nodules.

CEUS Examination of Thyroid Nodules

Most studies have performed CEUS for thyroid nodules according to the following criteria: (1) histopathologically confirmed (surgical or US-guided biopsy) thyroid nodules, (2) solid or almost solid (<25% cystic) nodules on conventional US, (3) thyroid nodules with malignant tendencies (e.g., Thyroid Imaging Reporting and Data System [TI-RADS] category 4 on conventional US), and (4) modules larger than 0.5 cm in diameter. Common exclusion criteria are (1) nodules with coarse calcifications, (2) predominantly cystic nodules, (3) a nodule diameter <5 mm, and (4) pregnancy. The general process of CEUS for thyroid nodules is as follows. The largest view of the nodule is chosen before switching to the CEUS mode from conventional US. The focus zone is always placed at the bottom level of the nodule, and CEUS is performed using a low mechanical index (MI) (<0.10). SonoVue is injected intravenously as a bolus at a dose from 1.2 to 4.8 mL, followed by a 5-mL saline flush. The timer on the US machine is started during the CEUS process, and the images obtained during the next 2-3 minutes are digitally stored as raw data. The diagnosis of thyroid nodules includes both a qualitative analysis and a quantitative analysis, mainly depending on the CEUS enhancement patterns of thyroid nodules relative to the surrounding parenchyma, including the following parameters. The enhancement degree (i.e., hyperenhancement, isoenhancement, and hypoenhancement) of the thyroid nodule is defined as a peak intensity higher than, equal to, or lower than the perinodular tissue, respectively. The enhancement pattern is defined as either centripetal enhancement, if enhancement moves from the periphery to the center, or entire enhancement, if the peripheral and central areas synchronously show enhancement. Homogeneous lesions are defined as those in which the entire lesion shows full enhancement, regardless of the enhancement degree, while heterogeneous lesions are enhanced lesions that contain areas without any enhancement. Wash-in and wash-out refer to enhancement that appears or disappears earlier, at the same time as, or later than the perinodular tissue, respectively. Ring enhancement is defined as an enhanced rim of peritumoral tissue that appears in the early phase and becomes more distinct in the late phase [10]. During the post-processing quantitative analysis of thyroid nodules, the operator manually draws an ROI covering the tissue to be studied, and a color map is automatically generated by the built-in analysis package or by using quantification software. Then, further and smaller ROIs of a similar size are hand-drawn on the color map within the tumor, and the following quantitative parameters are automatically calculated: peak intensity, the maximum intensity of the time-intensity curve, time to peak, the time needed to reach peak intensity, the mean transit time, the time for which intensity is higher than the mean value, and area under the time-intensity curve, proportional to the total volume of blood in the ROI and the sum of the areas of wash-in and wash-out [11].

Complications and Disadvantages of CEUS

CEUS suffers from the following limitations that have been described in the literature. First, microbubbles last only 5-10 minutes in circulation because they are taken up either by immune system cells or by the liver or spleen. Second, ultrasound produces more heat as the frequency increases, so the ultrasonic frequency must be carefully adjusted. Third, microbubbles burst at low ultrasound frequencies and at high MIs, which is a measure of the negative acoustic pressure of the ultrasound imaging system. Increasing the MI increases image quality, but there are tradeoffs with microbubble destruction. Microbubble destruction can cause local microvasculature ruptures and hemolysis [12]. Rare reports of fatal events have been reported with CEUS. The overall rates of adverse reactions from the use of SonoVue was reported to be 0.0086%, which appears to be lower than the comparable rates for contrast agents used in computed tomography or magnetic resonance imaging [13].

CEUS Patterns Characteristic of Malignant Thyroid Nodules

Hypoenhancement is considered to be a major CEUS pattern characteristic of malignant thyroid nodules (Fig. 1) [14-17], especially for thyroid tumors 10 mm or less in diameter [18]. This finding is counterintuitive, because malignant tumors in other organs are well supplied by blood vessels. Hypoenhancement in malignant thyroid nodules has also been termed an "absent" pattern in some studies [19]. The main reason that thyroid malignant tumors show a lack of blood supply is that the tumors grows with complex neovascularization inside it; once the growth outweighs neovascularization, necrosis and embolus formation happens within the tumor, ultimately leading to hypoenhancement on CEUS. Moreover, Zhou et al. [20] found that instead of hypoenhancement, the nodule-to-perinodule peak intensity ratio showed the best diagnostic efficiency, with an optimal cutoff value of 0.9.
Fig. 1.

Conventional ultrasonography (US) and contrast-enhanced ultrasound (CEUS) imaging of papillary thyroid carcinoma in a 32-year-old man.

A. Gray-scale US shows a hypoechoic solid nodule in the right thyroid lobe with a poorly defined margin, assessed as Thyroid Imaging Reporting and Data System category 4C. B. Color Doppler US shows branching vessels (arrow) within the mass. C. CEUS shows hypoenhancement with penetrating vessels (arrow) in the mass.

Heterogeneous enhancement is another important CEUS pattern characteristic of malignant thyroid nodules (Fig. 2) [21-24]. Ma et al. [21] observed that the blood vessels of malignant nodules are typically aberrant and tortuous. Most malignant nodules contain areas of fibrosis, calcification, or focal necrosis, which may explain the trend for heterogeneous enhancement. Moreover, heterogeneous enhancement was found to be the best indicator for predicting malignancy in multivariate logistic regression analysis.
Fig. 2.

Conventional ultrasonography (US) and contrast-enhanced ultrasound (CEUS) imaging of papillary thyroid carcinoma in a 64-year-old man.

A. Gray-scale US shows a mixed-texture nodule (arrow) in the left thyroid lobe with calcification, assessed as Thyroid Imaging Reporting and Data System category 4B. LCCA, left common carotid artery. B. Color Doppler US shows peripheral and interior blood flow. C. CEUS shows heterogeneous isoenhancement in the mass.

Heterogeneity has generally been considered to be a subjective, qualitative CEUS characteristic. However, Jin et al. [25] used an algorithm to quantify the heterogeneity of enhancement of solid thyroid nodules on CEUS. The heterogeneity value (HV) was calculated as standard deviation/mean intensity×100 (using Adobe Photoshop). The heterogeneity ratio (HR) was calculated as the ratio of the HV of the nodule to that of the surrounding parenchyma. HV and HR were significantly higher in malignant nodules than in benign nodules. This algorithm used for the assessment of image heterogeneity on CEUS examinations may be a useful adjunct to conventional US for the differential diagnosis of solid thyroid nodules. As well as quantifying enhancement heterogeneity, CEUS can also be used to assess thyroid nodules using other indicators, most notably arrival time and time to peak. Some published studies have shown that earlier wash-in, wash-out, and time to peak were associated with malignancy [18,26-30]. This could be due to the reduced microvascularization in carcinomas as a result of necrosis. Conversely, Yuan et al. [31] and Wu et al. [32] recently reported that the majority of thyroid carcinomas were enhanced later than the surrounding thyroid gland. Furthermore, in some studies, quantitative evaluations did not prove useful for distinguishing between benign and malignant nodules, as the time parameters were different between malignant and benign lesions, but not significantly so [33]. Nemec et al. [29] found that relative enhancement during the wash-out curve (ratio of enhancement at 20 seconds after peak enhancement to baseline intensity) was lower in malignant nodules than in benign nodules, and 2.35 was the optimal threshold of this parameter for differentiating benign and malignant thyroid nodules.

CEUS Patterns Characteristic of Benign Thyroid Nodules

In contrast to the various CEUS patterns characteristic of malignant nodules, the consensus on diagnostic criteria for benign nodules is that homogeneity and ring enhancement are the most two valuable CEUS indicators for predicting benignity (Fig. 3), and these parameters have frequently been evaluated in studies [14,15,22- 24,34].
Fig. 3.

Conventional ultrasonography (US) and contrast-enhanced US (CEUS) imaging of thyroid adenoma in a 35-year-old woman.

A. Gray-scale US shows an isoechoic nodule in the left thyroid lobe with a well-defined margin, assessed as Thyroid Imaging Reporting and Data System category 3. B. Color Doppler US shows mainly interior blood flow, with absent peripheral blood flow. C. CEUS shows homogeneity and ring enhancement in the mass.

To summarize, CEUS is a promising noninvasive technique for the differential diagnosis of benign and malignant thyroid nodules (Table 1). According to meta-analyses, its sensitivity is 85% to 88%, and its specificity is 88% to 90% [35,36]. However, some studies [17,21,23,24,28,33] have found that the contrast enhancement pattern might overlap between malignant and benign thyroid nodules. Some nodules with typically benign contrast enhancement patterns exhibited malignant behavior; for instance, some benign nodules had non-homogeneous enhancement due to necrosis. Therefore, many scholars combined CEUS with other US methods to improve diagnostic accuracy.
Table 1.

Criteria and diagnostic value for CEUS in the differential diagnosis between benign and malignant thyroid nodules

StudyYearDiagnostic criteria for malignancySensitivitySpecificityAccuracy
Schleder et al. [14]2015No wash-out or wash-out in late phase21/2669/7590/101
Jiang et al. [15]2015Non-homogeneous, hypoenhancement44/4967/73111/122
Ma et al. [21]2014Heterogeneous enhancement85/9471/78156/172
Zhang et al. [22]2010Heterogeneous enhancement45/5149/5394/104
Zhang et al. [24]2016Low enhancement or a peripheral irregular ring82/8249/75121/157
Cantisani et al. [26]2013Heterogeneous, absent wash-in15/1931/3446/53
Wendl et al. [28]2016Accelerated TTP at the center of the lesion16/2019/3035/50
Nemec et al. [29]2012Relative enhancement of 2.35 as the optimal threshold10/1322/3332/46
Yuan et al. [31]2015Irregular shape of enhanced lesions35/3736/4171/78
Zhang et al. [37]2017Heterogeneous enhancement58/75230/244288/319
Li et al. [42]2015Non-homogeneous and low enhancement44/5024/3068/80
Giusti et al. [43]2014TTP index >0.987/1346/5053/63
Deng et al. [45]2014Hypoenhancement46/56101/119147/175

CEUS, contrast-enhanced ultrasound; TTP, time to peak.

CEUS Combined with Conventional US

Zhang et al. [37] combined CEUS with an assessment of TI-RADS categories based on conventional US in the differential diagnosis of thyroid nodules, and found that the combination significantly improved the diagnostic accuracy (96% vs. 90%), especially for TI-RADS class 4 thyroid nodules. In another study, Kwak et al. [38] used TI-RADS and hypo-enhancement by CEUS criteria to predict malignancy. Furthermore, Zhao et al. [16], Li and Luo [17], and Zhang et al. [39] similarly concluded that combining CEUS with conventional US could improve diagnostic accuracy.

CEUS Combined with Real-Time Elastography and Conventional US

Real-time elastography (RTE) is a reproducible sonographic assessment of tissue consistency using external compression or carotid artery vibrations [40]. Similar to palpation, the rationale of RTE is that cancerous nodules are stiffer, with less elastic deformation than the surrounding thyroid tissue or benign thyroid nodules (Fig. 4).
Fig. 4.

Conventional ultrasonography (US), real-time elastography (RTE), and contrast-enhanced US (CEUS) imaging of thyroid adenoma in a 35-year-old man.

A. Gray-scale US shows a hypoechoic solid nodule in the right thyroid lobe with calcification assessed as Thyroid Imaging Reporting and Data System category 4C. B. RTE is mainly red and slightly yellow, which means that the nodule is probably hard. C. CEUS shows heterogeneous isoenhancement in the mass.

A previous study [41] reported that the combination of US, RTE, and CEUS could increase both the sensitivity and specificity of all three methods. With regard to comparisons between individual methods, most studies [20,42,43] showed that RTE was the most valuable tool. Giusti et al. [44] found that RTE and CEUS showed no advantages over US, and in a further study, demonstrated that the information added by CEUS was less sensitive than that provided by US and RTE.

CEUS Combined with Acoustic Radiation Force Impulse Imaging

Acoustic radiation force impulse imaging (ARFI) is a novel US-based elastography method enabling the quantitative measurement of tissue stiffness derived from qualitative RTE. Deng et al. [45] reported that the combination of conventional US, ARFI, and CEUS significantly improved diagnostic accuracy compared with any of these modalities singly or a combination of conventional US and ARFI (Fig. 5).
Fig. 5.

Conventional ultrasonography (US), acoustic radiation force impulse imaging (ARFI), and contrastenhanced US (CEUS) imaging of thyroid adenoma in a 35-year-old man.

A. Gray-scale US shows a hypoechoic solid nodule in the isthmus with capsule contact assessed as Thyroid Imaging Reporting and Data System category 4C. B. ARFI is mainly red and slightly yellow, and the median shear wave velocity was 7.82 m/sec, which means that the nodule was very hard. C. CEUS shows hypoenhancement in the mass.

Zhan et al. [46] used ARFI as a preliminary screening tool for the differential diagnosis of thyroid nodules, while CEUS was used as a supplement for nodules that were difficult to distinguish by ARFI. CEUS can be combined with a processing technique to represent 3-dimensional (3D) internal flow. Molinari et al. [47] developed an image processing technique for characterizing the intranodular vascularization of thyroid lesions by 3D CEUS imaging. The results showed that malignant nodules had higher values for the number of vascular trees, vascular density, the number of branching nodes, 2D and 3D tortuosity, and the inflection count metric. This technique enables quantitative 3D CEUS and skeletonization to be used in the differential diagnosis of thyroid lesions. In addition to the differential diagnosis of benign and malignant thyroid nodules, CEUS has been applied to assess other thyroid-related diseases.

CEUS Evaluation of US-Guided Laser Ablation for Benign Thyroid Nodules

Ma et al. [48] evaluated the single-session complete ablation rate of US-guided percutaneous laser ablations for benign thyroid nodules, and found that all nodule volumes significantly decreased from the original size at 1 day after ablation. CEUS is regarded as the main method for evaluating laser ablation treatment. During the procedure, if CEUS shows nodules with a small amount of residual tissue at the edge, the patient requires further ablation treatment until the remnants of the lesion disappear completely.

CEUS Detection of Extrathyroid Extension or Neck Lymph Node Metastasis in Papillary Thyroid Carcinoma

In a previous study, CEUS and tumor size were compared between extrathyroid extension (ETE) and non-ETE groups [49]. Multivariate stepwise logistic regression analysis demonstrated that the time from peak to one-half tumor size and wash-in slope were significantly different between the ETE and non-ETE groups. Xiang et al. [50] evaluated the value of CEUS as a non-invasive tool for detecting neck lymph node metastasis and the enhancement patterns of malignant lymph nodes for papillary thyroid carcinoma. Their results showed that heterogeneous enhancement, perfusion defects, microcalcification, and centripetal/hybrid enhancement were specific criteria for malignant lymph nodes in a univariate analysis. Furthermore, Hong et al. [51] reported a similar conclusion.

CEUS Used to Evaluate Papillary Thyroid Carcinoma Patients with Breast Cancer

Wei et al. [52] found that the mean and peak intensities were higher in thyroid cancers in patients with breast cancer than in those without breast cancer, and these parameters were significantly associated with the microvessel density count and vascular endothelial growth factor expression.

Conclusion

The present review showed that no isolated CEUS feature is capable of predicting malignancy in thyroid nodules with acceptable diagnostic accuracy. However, the presence of some CEUS features such as hypoenhancement and heterogeneity can be used to identify nodules with an elevated risk for malignancy; in addition, homogeneity and ring enhancement indicate benignity. Moreover, with further research, CEUS could potentially play a more important role in the detection of extranodular extension of malignant nodules and in evaluating treatment response. Nevertheless, more studies are required to standardize the technique and to confirm its usefulness.
  51 in total

1.  Qualitative and quantitative evaluation of solitary thyroid nodules with contrast-enhanced ultrasound: initial results.

Authors:  Tommaso Vincenzo Bartolotta; Massimo Midiri; Massimo Galia; Giuseppe Runza; Marco Attard; Giovanni Savoia; Roberto Lagalla; Adelfio Elio Cardinale
Journal:  Eur Radiol       Date:  2006-05-03       Impact factor: 5.315

2.  The safety of Sonovue in abdominal applications: retrospective analysis of 23188 investigations.

Authors:  Fabio Piscaglia; Luigi Bolondi
Journal:  Ultrasound Med Biol       Date:  2006-09       Impact factor: 2.998

3.  Real-time elastography and contrast-enhanced ultrasound for the assessment of thyroid nodules.

Authors:  M Friedrich-Rust; A Sperber; K Holzer; J Diener; F Grünwald; K Badenhoop; S Weber; S Kriener; E Herrmann; W O Bechstein; S Zeuzem; J Bojunga
Journal:  Exp Clin Endocrinol Diabetes       Date:  2009-10-23       Impact factor: 2.949

4.  Is there a real diagnostic impact of elastosonography and contrast-enhanced ultrasonography in the management of thyroid nodules?

Authors:  Massimo Giusti; Davide Orlandi; Giulia Melle; Barbara Massa; Enzo Silvestri; Francesco Minuto; Gianni Turtulici
Journal:  J Zhejiang Univ Sci B       Date:  2013-03       Impact factor: 3.066

5.  Characterization of single thyroid nodules by contrast-enhanced 3-D ultrasound.

Authors:  Filippo Molinari; Alice Mantovani; Maurilio Deandrea; Paolo Limone; Roberto Garberoglio; Jasjit S Suri
Journal:  Ultrasound Med Biol       Date:  2010-10       Impact factor: 2.998

6.  Second generation ultrasonographic contrast agents in the diagnosis of neoplastic thyroid nodules.

Authors:  M Appetecchia; D Bacaro; R Brigida; D Milardi; A Bianchi; F Solivetti
Journal:  J Exp Clin Cancer Res       Date:  2006-09

7.  Preoperative differentiation of thyroid adenomas and thyroid carcinomas using high resolution contrast-enhanced ultrasound (CEUS).

Authors:  S Schleder; M Janke; A Agha; D Schacherer; M Hornung; H J Schlitt; C Stroszczynski; A G Schreyer; E M Jung
Journal:  Clin Hemorheol Microcirc       Date:  2015       Impact factor: 2.375

8.  Diagnostic value of contrast-enhanced ultrasound in papillary thyroid microcarcinoma.

Authors:  Hong Yan Chen; Wei Yan Liu; Hui Zhu; Dao Wen Jiang; Dong Hua Wang; Yongqi Chen; Weihua Li; Gaofeng Pan
Journal:  Exp Ther Med       Date:  2016-02-19       Impact factor: 2.447

9.  Diagnostic Accuracy of Contrast-Enhanced Ultrasound Enhancement Patterns for Thyroid Nodules.

Authors:  Yan Zhang; Yu-Kun Luo; Ming-Bo Zhang; Jie Li; Junlai Li; Jie Tang
Journal:  Med Sci Monit       Date:  2016-12-05

10.  Utility of quantitative contrast-enhanced ultrasound for the prediction of extracapsular extension in papillary thyroid carcinoma.

Authors:  Yi Liu; Hua Liu; Chang-Lin Qian; Mei-Sui Lin; Feng-Hua Li
Journal:  Sci Rep       Date:  2017-05-03       Impact factor: 4.379

View more
  8 in total

1.  Systematic review and meta-analysis: diagnostic value of different ultrasound for benign and malignant thyroid nodules.

Authors:  Yin Wu; Chunmei Zhou; Bo Shi; Zhuohua Zeng; Xinyu Wu; Jiakai Liu
Journal:  Gland Surg       Date:  2022-06

2.  US-Guided Radiofrequency Ablation for Low-Risk Papillary Thyroid Microcarcinoma: Efficacy and Safety in a Large Population.

Authors:  Hyun Kyung Lim; Se Jin Cho; Jung Hwan Baek; Kang Dae Lee; Chang Woo Son; Jung Min Son; Seon Mi Baek
Journal:  Korean J Radiol       Date:  2019-12       Impact factor: 3.500

3.  Contrast-Enhanced Ultrasound in the Differential Diagnosis of Primary Thyroid Lymphoma and Nodular Hashimoto's Thyroiditis in a Background of Heterogeneous Parenchyma.

Authors:  Lulu Yang; Haina Zhao; Yushuang He; Xianglan Zhu; Can Yue; Yan Luo; Buyun Ma
Journal:  Front Oncol       Date:  2021-01-07       Impact factor: 6.244

Review 4.  2021 Korean Thyroid Imaging Reporting and Data System and Imaging-Based Management of Thyroid Nodules: Korean Society of Thyroid Radiology Consensus Statement and Recommendations.

Authors:  Eun Ju Ha; Sae Rom Chung; Dong Gyu Na; Hye Shin Ahn; Jin Chung; Ji Ye Lee; Jeong Seon Park; Roh-Eul Yoo; Jung Hwan Baek; Sun Mi Baek; Seong Whi Cho; Yoon Jung Choi; Soo Yeon Hahn; So Lyung Jung; Ji-Hoon Kim; Seul Kee Kim; Soo Jin Kim; Chang Yoon Lee; Ho Kyu Lee; Jeong Hyun Lee; Young Hen Lee; Hyun Kyung Lim; Jung Hee Shin; Jung Suk Sim; Jin Young Sung; Jung Hyun Yoon; Miyoung Choi
Journal:  Korean J Radiol       Date:  2021-10-26       Impact factor: 3.500

5.  Exploring the Value of Radiomics Features Based on B-Mode and Contrast-Enhanced Ultrasound in Discriminating the Nature of Thyroid Nodules.

Authors:  Shi Yan Guo; Ping Zhou; Yan Zhang; Li Qing Jiang; Yong Feng Zhao
Journal:  Front Oncol       Date:  2021-10-14       Impact factor: 6.244

6.  TI-RADS Diagnostic Performance: Which Algorithm is Superior and How Elastography and 4D Vascularity Improve the Malignancy Risk Assessment.

Authors:  Andreea Borlea; Florin Borcan; Ioan Sporea; Cristina Adriana Dehelean; Romeo Negrea; Laura Cotoi; Dana Stoian
Journal:  Diagnostics (Basel)       Date:  2020-03-26

7.  Contrast-Enhanced Ultrasound in the Differential Diagnosis and Risk Stratification of ACR TI-RADS Category 4 and 5 Thyroid Nodules With Non-Hypovascular.

Authors:  Yanfang Wang; Tiantian Dong; Fang Nie; Guojuan Wang; Ting Liu; Qian Niu
Journal:  Front Oncol       Date:  2021-05-26       Impact factor: 6.244

Review 8.  Contrast-enhanced ultrasound of the small organs in children.

Authors:  Maciej Piskunowicz; Susan J Back; Kassa Darge; Paul D Humphries; Jörg Jüngert; Damjana Ključevšek; Norbert Lorenz; Hans-Joachim Mentzel; Judy H Squires; Dean Y Huang
Journal:  Pediatr Radiol       Date:  2021-04-08
  8 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.