Eduardo K Kohara1, Camilla G Abdala1,2, Tatiane F Novaes1,3, Mariana M Braga1, Ana E Haddad1,4, Fausto M Mendes1.
Abstract
The purpose of this study was to compare the performance of two different models of smartphone and a conventional camera with that of direct clinical examination in detecting caries lesions at different stages of progression in deciduous molars. The photographic equipment consisted of two smartphones (iPhone and Nexus 4) and a conventional macro camera setup. First, in the laboratory phase of the study, we compared the images of 20 exfoliated primary teeth having caries lesions at different stages. Then, in the clinical phase of the study, the images of 119 primary molars from fifteen children (3 to 6 years old) were used. All of the photographic images were taken using the previously described devices. In both groups, two examiners, blinded to the photographic equipment used, assessed the images independently on a computer screen, and classified them according to the International Caries Detection and Assessment System (ICDAS). The teeth were then examined directly by two other experienced examiners, and the consensus reached was considered the reference standard. Parameters of validity, such as percentage of correct answers, agreement with the reference standard, sensitivity, specificity and inter-examiner agreement (using the weighted kappa test) were calculated. The examiners performed similarly in both in vitro and in vivo studies. Inter-examiner reliability was approximately 0.7 for all the devices in the laboratory setting, and for the macro camera photography system in the clinical setting, but it was approximately 0.9 for the iPhone and Nexus images taken in vivo. With regard to the percentage of correct answers, the highest values were observed for sound and extensive caries lesions in both laboratory and clinical settings. The percentage of correct answers for initial and moderate lesions was particularly low in the clinical evaluation, irrespective of the camera devices used. Therefore, we concluded that photographic diagnosis using smartphone images is feasible and accurate for distinguishing sound tooth surfaces from extensive caries lesions; however, photographic images are not a good method for accurately detecting initial and moderate caries lesions.Entities:
Mesh:
Year: 2018 PMID: 30188900 PMCID: PMC6126822 DOI: 10.1371/journal.pone.0202116
Source DB: PubMed Journal: PLoS One ISSN: 1932-6203 Impact factor: 3.240
Agreement between assessments and number (and %) of correct assessments made by two examiners during the in vitro detection of caries lesions in pictures of tooth surfaces taken with different camera devices (a macro camera and two smartphones), using the International Caries Detection and Assessment System (ICDAS), as compared with direct visual inspection.
| Camera devices | Weighted kappa values | Sound surfaces | Initial lesions | Moderate lesions | Cavitated lesions |
|---|---|---|---|---|---|
| N (%) | |||||
| Direct clinical assessment | 2 | 9 | 10 | 8 | |
| Macro | 0.617 (0.360 to 0.874) | 2 (100.0) | 5 (55.6) | 4 (40.0) | 6 (75.0) |
| iPhone | 0.559 (0.318 to 0.800) | 2 (100.0) | 4 (44.4) | 2 (20.0) | 6 (75.0) |
| Nexus | 0.541 (0.301 to 0.781) | 2 (100.0) | 4 (44.4) | 1 (10.0) | 6 (75.0) |
| Macro | 0.650 (0.414 to 0.886) | 2 (100.0) | 6 (66.7) | 4 (40.0) | 7 (87.5) |
| iPhone | 0.733 (0.534 to 0.932) | 2 (100.0) | 3 (33.3) | 9 (90.0) | 7 (87.5) |
| Nexus | 0.619 (0.388 to 0.851) | 2 (100.0) | 3 (33.3) | 5 (50.0) | 7 (87.5) |
95% CI = 95% confidence intervals
In vitro and in vivo inter-examiner reliability between the two examiners in detecting caries lesions in pictures of tooth surfaces taken with different camera devices, using the International Caries Detection and Assessment System (ICDAS).
| Camera devices | Weighted kappa values (95% confidence interval) | |
|---|---|---|
| Macro | 0.768 (0.582 to 0.954) | 0.695 (0.549 to 0.842) |
| iPhone | 0.615 (0.382 to 0.847) | 0.973 (0.962 to 0.985) |
| Nexus | 0.605 (0.357 to 0.853) | 0.895 (0.796 to 0.994) |
Agreement between assessments and number (and %) of correct assessments made by two examiners during the in vivo detection of caries lesions in pictures of tooth surfaces taken with different camera devices (a macro camera and two smartphones), using the International Caries Detection and Assessment System (ICDAS), as compared with the consensual assessments made by two examiners performing direct visual inspection.
| Camera devices | Weighted kappa values | Sound surfaces | Initial lesions | Moderate lesions | Cavitated lesions |
|---|---|---|---|---|---|
| N (%) | |||||
| Direct clinical assessment | 6 | 64 | 29 | 20 | |
| Macro | 0.663 (0.566 to 0.760) | 6 (100.0) | 7 (10.9) | 4 (13.8) | 20 (100.0) |
| iPhone | 0.638 (0.532 to 0.743) | 6 (100.0) | 3 (4.7) | 2 (6.9) | 19 (95.0) |
| Nexus | 0.606 (0.498 to 0.714) | 6 (100.0) | 2 (3.1) | 0 (0.0) | 18 (90.0) |
| Macro | 0.540 (0.404 to 0.677) | 5 (83.3) | 3 (4.7) | 2 (6.9) | 16 (80.0) |
| iPhone | 0.636 (0.531 to 0.740) | 6 (100.0) | 11 (17.2) | 2 (6.9) | 17 (85.0) |
| Nexus | 0.530 (0.403 to 0.656) | 6 (100.0) | 2 (3.1) | 3 (10.3) | 15 (75.0) |
95% CI = 95% confidence intervals
Sensitivity and specificity of the assessments made by two examiners during the in vivo detection of caries lesions in pictures taken with different camera devices, using the International Caries Detection and Assessment System (ICDAS), and considering three different thresholds: initial lesions, moderate lesions and extensive lesions.
| Camera devices | Sensitivity | Specificity | ||||
|---|---|---|---|---|---|---|
| Initial | Moderate | Extensive | Initial | Moderate | Extensive | |
| 40.7 (31.6 to 50.4) | 59.2 (44.2 to 73.0) | 100.0 (83.2 to 100.0) | 100.0 (54.1 to 100.0) | 95.7 (88.0 to 99.1) | 93.9 (87.3 to 97.7) | |
| 33.6 (25.0 to 43.1) | 53.1 (38.3 to 67.5) | 95.0 (75.1 to 99.9) | 100.0 (54.1 to 100.0) | 98.6 (92.3 to 100.0) | 93.9 (87.3 to 97.7) | |
| 30.1 (21.8 to 39.4) | 51.0 (36.3 to 65.6) | 90.0 (68.3 to 98.8) | 83.3 (35.9 to 99.6) | 97.1 (90.1 to 99.7) | 91.9 (84.7 to 96.4) | |
| 32.7 (24.2 to 42.2) | 51.0 (36.3 to 65.6) | 80.0 (56.3 to 94.3) | 83.3 (35.9 to 99.6) | 95.7 (88.0 to 99.1) | 90.9 (83.4 to 95.8) | |
| 39.8 (30.7 to 49.5) | 53.1 (38.3 to 67.5) | 85.0 (62.1 to 96.8) | 100.0 (54.1 to 100.0) | 98.6 (92.3 to 100.0) | 95.0 (88.6 to 98.3) | |
| 29.2 (21.0 to 38.5) | 46.9 (32.5 to 61.7) | 75.0 (50.9 to 91.3) | 100.0 (54.1 to 100.0) | 97.1 (90.1 to 99.7) | 96.0 (90.0 to 98.9) | |
The figures in parentheses represent the 95% confidence intervals