Endoscopic drainage of pancreatic fluid collections by use of a novel biflanged stent with electrocautery-enhanced delivery system.

Sundeep Lakhtakia1, Zaheer Nabi1, Jong Ho Moon2, Rajesh Gupta1, Radhika Chavan1, Jahangeer Basha1, D Nageshwar Reddy1.   

Abstract

Entities:  

Keywords:  ANP, acute necrotizing pancreatitis; BFMS, biflanged metal stents; CP, chronic pancreatitis; EC-BFMS, BFMS with electrocautery-enhanced delivery system; EC-LAMS, LAMS with electrocautery-enhanced delivery system; LAMS, large-caliber metal stents; PFC, pancreatic fluid collection; WON, walled-off necrosis

Year:  2018        PMID: 30182090      PMCID: PMC6118233          DOI: 10.1016/j.vgie.2018.07.001

Source DB:  PubMed          Journal:  VideoGIE        ISSN: 2468-4481


× No keyword cloud information.
Endoscopic drainage is currently the preferred modality of drainage for pancreatic fluid collections (PFCs) because of the ease of the procedure, reduced cost, shorter hospital stay, and the reduced morbidity and mortality compared with traditional surgical drainage. Plastic stents used for endoscopic drainage may become blocked with the passage of time, leading to adverse events requiring reinterventions, especially in PFCs with significant debris (ie, walled-off necrosis [WON]). Novel large-caliber metal stents (LCMSs) are less prone to spontaneous occlusions and therefore, provide efficient drainage of PFCs. Large-caliber metal stents have been broadly classified as either lumen-apposing metal stents (LAMSs) or biflanged metal stents (BFMSs). The safety and efficacy of these stents have been established in multiple studies.2, 3 The deployment of novel metal stents involves a series of well-coordinated steps including real-time endosonography, fluoroscopy, and endoscopic imaging. Recently, LAMSs with an electrocautery-enhanced delivery system (Hot AXIOS; Boston Scientific Corp, Marlborough, Mass, USA) have been introduced. The stent assembly has inbuilt multiple steps for deployment, making the drainage procedure easier.4, 5, 6 In this study, we aimed to evaluate the feasibility and safety of a novel BFMS with electrocautery-enhanced delivery system (EC-BFMS) (Video 1, available online at www.VideoGIE.org).

Methods

Five patients with symptomatic PFCs undergoing drainage with the EC-BFMS were included in the analysis. The PFCs were classified as WON or pseudocyst according to the revised Atlanta guidelines. The data were extracted from a prospectively collected database and analyzed retrospectively. The study was approved by the institution’s review board.

Drainage technique

All the PFCs were drained under EUS guidance after thorough assessment and choice of an appropriate site for drainage. The standard sequence of steps for EUS-guided drainage of PFCs with conventional BFMSs are (1) puncture of the PFC with a 19-gauge needle, (2) coiling of a guidewire inside the PFC, (3) creation of a cystogastric fistula by use of a 6F cystotome over the guidewire, (4) dilation of the fistula with a small-caliber balloon, and (5) deployment of the stent under EUS, fluoroscopic, and endoscopic guidance. The important differences in drainage technique when the EC-BFMS was used are as follows. First, the cyst wall was punctured either with a 19-gauge regular FNA needle or directly with the electrocautery-enabled stent assembly with a free-hand technique, depending on the operator’s preference. Second, steps 3 and 4 (see above), including the use of a cystotome and balloon for creating a cystogastric tract were omitted. Third, the guidewire was not coiled in all cases, and the decision to coil the guidewire inside the cyst cavity was left to the endoscopist’s discretion. Technical success was defined as successful deployment of the EC-BFMS. Clinical success was defined as resolution of symptoms along with >50% reduction in the size of the PFC cavity. All intraprocedural and postprocedural adverse events were recorded.

Postprocedure follow-up

All the patients were followed up clinically and radiologically. If clinical symptoms persisted at 48 to 72 hours, a nasocystic drainage tube was placed for flushing with diluted hydrogen peroxide and saline solution. Subsequently, direct endoscopic necrosectomy was considered for patients with persistent symptoms. The stents were removed about 4 weeks after initial placement. MRCP, endoscopic retrograde pancreatography, or both were performed before removal of the stents to delineate pancreatic ductal anatomy. A pancreatic ductal stent was placed in case a ductal stricture or leak was demonstrated.

Electrocautery-enhanced BFMS

The EC-BFMS (Hot Nagi Taewoong Medical, Gyenoggi-do, Korea) device is a through-the-scope BFMS delivery system (10F) (Fig. 1). The delivery system has a conical hollow stiff metallic tip, which is connected by an internal fine wire to the connector hub handle. The tip enables passage of the stent assembly without any dilation of the tract. This allows the operator to place the stent directly without intervening steps like guidewire placement, passage of a cystotome to create a fistula, or balloon dilation to allow passage of a stent assembly. The BFMS is a conventional fully covered metal stent made of nitinol with flared ends and covered with silicone membrane. The EC-BFMS is available in 2 lengths (20 and 30 mm) and 4 diameters (10, 12, 14, and 16 mm). The stent flanges measure 26 mm in diameter. The recommended settings on an electrosurgical generator are 80 to 120 watts on pure cut mode.
Figure 1

Components of electrocautery-enhanced stent delivery system. A, Novel biflanged metal stent. B, Electrocautery-enhanced stent delivery system. C, Magnified view of electrocautery plug. D, Electrocautery-enabled tip of catheter.

Components of electrocautery-enhanced stent delivery system. A, Novel biflanged metal stent. B, Electrocautery-enhanced stent delivery system. C, Magnified view of electrocautery plug. D, Electrocautery-enabled tip of catheter.

Results

A total of 5 patients, all men (median age, 31 years; range, 18-39 years), underwent EUS-guided drainage of PFCs by use of an EC-BFMS equipped with an electrocautery-enhanced delivery system. Technical success was achieved in all the patients. Of these, the PFCs in 4 patients were WON, and 1 was a pseudocyst according to the revised Atlanta classification. The median size of fluid collections was 9.8 cm (range, 7.7-17 cm). The mean wall thickness of the PFCs at point of entry was 4.38 ± 1.02 mm (range, 3.2-5.6 mm) (Table 1). In 2 cases, a 16- × 30-mm stent was used; in the other 3 cases, a 16- × 20-mm stent was used.
Table 1

Characteristics of patients who underwent drainage with EC-BFMSs

No.AgeSexAcute or chronic pancreatitisType of PFCSize of PFC (mm)Wall thickness (mm)Needle used for punctureGuidewire securedProcedure duration (seconds)
1.26MANPWON155 × 1165.1YesYes445
2.39MANPWON170 × 1304.5YesYes420
3.32MANPWON98 × 805.6YesYes383
4.18MCPPseudocyst77 × 583.2NoYes200
5.31MANPWON95 × 553.5NoNo115

EC-BFMSs, BFMSs with electrocautery-enhanced delivery system; ANP, acute necrotizing pancreatitis; CP, chronic pancreatitis; PFC, pancreatic fluid collection; WON, walled-off necrosis.

Characteristics of patients who underwent drainage with EC-BFMSs EC-BFMSs, BFMSs with electrocautery-enhanced delivery system; ANP, acute necrotizing pancreatitis; CP, chronic pancreatitis; PFC, pancreatic fluid collection; WON, walled-off necrosis.

Procedure details

A 19-gauge EUS-FNA needle was used to puncture the cyst wall in the first 3 patients, in whom the PFC wall thickness at the entry point was 5.1, 4.5, and 5.6 mm, respectively (Fig. 2A). In the remaining 2 patients, the cyst wall was punctured directly with the electrocautery-enhanced stent delivery system (Fig. 2B). The wall thickness in the latter patients was 3.2 and 3.5 mm, respectively. After the cyst wall puncture, a guidewire was coiled inside the cyst wall cavity in 4 patients. In 1 case, the entire drainage procedure was performed in a single step without needle puncture and guidewire placement (Fig. 2C). The median procedure time (from PFC wall puncture to stent placement) was 383 seconds (range, 115-445 seconds). The mean time taken for the first 3 procedures where a needle was used for puncture was 416 seconds (range, 383-445 seconds). In the last 2 cases, where the EC-BFMS system was used directly for PFC wall puncture, the time taken was 200 and 115 seconds, respectively (Table 1). There was no technical failure, nor were there intraprocedural adverse events. One patient had a large PFC extending up to the paracolic gutter, where “combined drainage” was performed (ie, a percutaneous drain was placed from the flanks, followed by cystogastric EC-BFMS placement at the same session).
Figure 2

Fluoroscopic images of stent deployment techniques used in the study. A, Cyst wall puncture with a 19-gauge needle followed by coiling of guidewire in the cavity. B, Direct cyst wall puncture by use of the electrocautery-enabled stent delivery system followed by coiling of guidewire. C, Entire drainage procedure performed in a single step: cyst wall puncture with the electrocautery-enabled stent delivery system followed by deployment of stent.

Fluoroscopic images of stent deployment techniques used in the study. A, Cyst wall puncture with a 19-gauge needle followed by coiling of guidewire in the cavity. B, Direct cyst wall puncture by use of the electrocautery-enabled stent delivery system followed by coiling of guidewire. C, Entire drainage procedure performed in a single step: cyst wall puncture with the electrocautery-enabled stent delivery system followed by deployment of stent. Nasocystic tube placement and lavage with diluted hydrogen peroxide was performed in 3 patients for infected WON. Of these, direct endoscopic necrosectomy was performed in 2 patients. Clinical success was achieved in all 5 patients. All the EC-BFMSs were successfully removed at 4 weeks. The pancreatic duct was demonstrated to be normal on MRCP/endoscopic retrograde pancreatography in 3 patients. In 2 patients, a disconnected pancreatic duct was present. At a mean follow-up time of 10 months (range, 3-21 months), there were no recurrences of PFCs.

Statistical analysis

The data are presented as median or mean ± standard deviation.

Discussion

In this series, we demonstrated the feasibility and safety of drainage of PFCs using a BFMS with a new electrocautery-enhanced delivery system. The endoscopic drainage of PFCs, especially WON, has been revolutionized with the introduction of novel metal stents. These stents have a wide caliber for efficient drainage and are either biflanged or lumen-apposing in design, which gives them antimigration properties. We have previously demonstrated the utility of BFMSs for the drainage of PFCs in adults and also in children. The conventional deployment of metal stents under EUS guidance involves a series of steps, including puncture of the PFC wall with a regular FNA needle, coiling of a guidewire inside the cyst cavity, dilation of the cystogastric tract with a cautery and balloon, and finally deployment of the stent. These steps, in turn, require the exchange of several accessories like a cystotome and a balloon over the guidewire for the dilation of the cystogastric tract. The operator and the assistant have to act in synchrony, being vigilant to avoid losing access to the PFC cavity during these exchanges of accessories. The recently introduced LAMS on an electrocautery-enhanced delivery system carries the advantage of eliminating most of the steps required for deployment of the stent.4, 6, 8, 9, 10 Rinninella et al evaluated a novel LAMS (Hot AXIOS; Boston Scientific Corp) for the drainage of PFCs. This device is a through-the-scope stent delivery system with an electrocautery wire at the distal tip. Technical success was achieved in 98.9% of cases. Importantly, the PFC was punctured directly with the device in three-fourths of patients. The authors concluded that EUS-guided drainage with the electrocautery-enhanced delivery system is safe and easy to perform. In the present pilot study, we report the initial use of an electrocautery-enabled BFMS for the drainage of PFCs. Stent deployment was easy and successful in all cases. In our study, an FNA needle was used for puncture in the first 3 cases to avoid maldeployment or adverse events while we were getting accustomed to the new device. Direct puncture with the stent delivery system was done in the last 2 cases, where the PFC wall was thinner (<4 mm) and direct puncture appeared easier. With more experience using the novel stent delivery system, it is probable that an FNA needle might not be required for cyst puncture even in patients with thick-walled collections. The main advantage of the electrocautery-enabled system is that it simplifies the procedure and reduces the need for exchange of accessories. The operating time is considerably reduced, making the procedure efficient, which is especially important in sick patients. In this study, the median procedure time (PFC wall puncture to deployment of stent) was about 6 minutes. In the last case, in which the entire procedure was completed in a single step, the procedure time was about 2 minutes. In our experience, the approximate time to deploy a conventional Nagi stent is longer, averaging about 15 to 20 minutes. A recent study compared a BFMS (NAGI; Taewoong Medical, Gyenoggi-do, Korea) and a LAMS (Hot AXIOS; Boston Scientific Corp) with an electrocautery-enhanced delivery system. Technical and clinical success were similar in both groups. However, the median in-room procedure time was significantly shorter in the LAMS group (BFMS 62.5 minutes vs LAMS 45 minutes). The other advantage of the EC-BFMS system is its intuitive delivery system, which is analogous to conventional biliary and luminal metal stent delivery systems. This reduces the chances of losing access to the PFC cavity. Moreover, the additional cost of accessories involved at various steps is avoided. The currently available LAMSs with electrocautery-enhanced delivery system (EC-LAMS) (Hot AXIOS; Boston Scientific Corp), although efficient, has a complex nonintuitive delivery system. In one study, there was no significant difference in cost between the BFMS and the EC-LAMS. However, the cost efficiency of EC-BFMSs compared with conventional BFMSs remains to established. In conclusion, endoscopic drainage of PFCs is feasible and safe by use of a novel biflanged metal stent with an electrocautery-enhanced delivery system. Larger studies are required to establish the utility of this novel stent delivery system for drainage of PFCs.

Disclosure

Dr Reddy designed the Nagi stent used in this study for Taewoong Medical, Gyenoggido, Korea. All other authors disclosed no financial relationships relevant to this publication.
  10 in total

1.  Management of walled-off necrosis using the multiple transluminal gateway technique with the Hot AXIOS System.

Authors:  Ji Young Bang; Shyam Varadarajulu
Journal:  Dig Endosc       Date:  2015-11-19       Impact factor: 7.559

2.  Endoscopic "step-up approach" using a dedicated biflanged metal stent reduces the need for direct necrosectomy in walled-off necrosis (with videos).

Authors:  Sundeep Lakhtakia; Jahangeer Basha; Rupjyoti Talukdar; Rajesh Gupta; Zaheer Nabi; Mohan Ramchandani; B V N Kumar; Partha Pal; Rakesh Kalpala; P Manohar Reddy; R Pradeep; Jagadish R Singh; G V Rao; D Nageshwar Reddy
Journal:  Gastrointest Endosc       Date:  2016-11-11       Impact factor: 9.427

3.  EUS-guided drainage of peripancreatic fluid collections and necrosis by using a novel lumen-apposing stent: a large retrospective, multicenter U.S. experience (with videos).

Authors:  Ali A Siddiqui; Douglas G Adler; Jose Nieto; Janak N Shah; Kenneth F Binmoeller; Steve Kane; Linda Yan; Sobia N Laique; Thomas Kowalski; David E Loren; Linda Jo Taylor; Satish Munigala; Yasser M Bhat
Journal:  Gastrointest Endosc       Date:  2015-10-26       Impact factor: 9.427

4.  EUS-guided drainage of pancreatic fluid collections using a novel lumen-apposing metal stent on an electrocautery-enhanced delivery system: a large retrospective study (with video).

Authors:  Emanuele Rinninella; Rastislav Kunda; Markus Dollhopf; Andres Sanchez-Yague; Uwe Will; Ilaria Tarantino; Joan Gornals Soler; Sebastian Ullrich; Alexander Meining; Josè Miguel Esteban; Thomas Enz; Geoffroy Vanbiervliet; Frank Vleggaar; Fabia Attili; Alberto Larghi
Journal:  Gastrointest Endosc       Date:  2015-05-23       Impact factor: 9.427

5.  Classification of acute pancreatitis--2012: revision of the Atlanta classification and definitions by international consensus.

Authors:  Peter A Banks; Thomas L Bollen; Christos Dervenis; Hein G Gooszen; Colin D Johnson; Michael G Sarr; Gregory G Tsiotos; Santhi Swaroop Vege
Journal:  Gut       Date:  2012-10-25       Impact factor: 23.059

Review 6.  Endoscopic management of pancreatic fluid collections-revisited.

Authors:  Zaheer Nabi; Jahangeer Basha; D Nageshwar Reddy
Journal:  World J Gastroenterol       Date:  2017-04-21       Impact factor: 5.742

7.  Feasibility, safety, and outcomes of a single-step endoscopic ultrasonography-guided drainage of pancreatic fluid collections without fluoroscopy using a novel electrocautery-enhanced lumen-apposing, self-expanding metal stent.

Authors:  Joseph Yoo; Linda Yan; Raza Hasan; Saana Somalya; Jose Nieto; Ali A Siddiqui
Journal:  Endosc Ultrasound       Date:  2017 Mar-Apr       Impact factor: 5.628

8.  Intra-channel stent release technique for fluoroless endoscopic ultrasound-guided lumen-apposing metal stent placement: changing the paradigm.

Authors:  Andrea Anderloni; Fabia Attili; Silvia Carrara; Domenico Galasso; Milena Di Leo; Guido Costamagna; Alessandro Repici; Rastislav Kunda; Alberto Larghi
Journal:  Endosc Int Open       Date:  2017-01

9.  Multicenter experience from the UK and Ireland of use of lumen-apposing metal stent for transluminal drainage of pancreatic fluid collections.

Authors:  Suresh Vasan Venkatachalapathy; Noor Bekkali; Stephen Pereira; Gavin Johnson; Kofi Oppong; Manu Nayar; John Leeds; Bharat Paranandi; Ian Penman; Nicholas Carroll; Edmund Godfrey; Martin James; Guruprasad Aithal; Colin McKay; John Devlin; Terry Wong; Alistair Makin; Barbara Ryan; Matthew Huggett
Journal:  Endosc Int Open       Date:  2018-02-28

10.  A comparison of outcomes between a lumen-apposing metal stent with electrocautery-enhanced delivery system and a bi-flanged metal stent for drainage of walled-off pancreatic necrosis.

Authors:  Noor L H Bekkali; Manu K Nayar; John S Leeds; Richard M Charnley; Matthew T Huggett; Kofi W Oppong
Journal:  Endosc Int Open       Date:  2017-11-21
  10 in total
  2 in total

1.  Efficacy and safety of plastic versus lumen-apposing metal stents for transmural drainage of walled-off necrosis: a retrospective single-center study.

Authors:  Surinder Singh Rana; Ravi Sharma; Lovneet Dhalaria; Rajesh Gupta
Journal:  Ann Gastroenterol       Date:  2020-05-25

2.  Comparative outcomes of endoscopic ultrasound-guided lumen-apposing mental stents drainage for pancreatic pseudocysts and walled-off necrosis: Case series and meta-analysis.

Authors:  Jing Li; Qian Zhang; Anni Zhou; Guiping Zhao; Peng Li
Journal:  Chronic Dis Transl Med       Date:  2021-08-11
  2 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.