Seyyed Abolfazl Zakerian1, Saeid Yazdanirad1, Seifollah Gharib1, Kamal Azam2, Asma Zare1,3.
Abstract
BACKGROUND: Lighting is one of the environmental factors affecting the performance of the control room operators. Therefore, the aim of this study was to compare the control room operators' visual performance in two different illumination conditions at a combined cycle power plant through field-work.Entities:
Keywords: Control room; Lighting; Power plant; Visual acuity; Visual performance
Year: 2018 PMID: 30181884 PMCID: PMC6116454 DOI: 10.1186/s40557-018-0267-3
Source DB: PubMed Journal: Ann Occup Environ Med ISSN: 2052-4374
Fig. 1The example of the four main directions of the responses (a), aciuty C test (b), contrast C test (c)
Fig. 2View of the room before and after the intervention (a. before the intervention, b. after the intervention)
Average values of general and local illumination and luminance before and after the intervention
| Parameters | Average of general illumination in control-room (Lux) | Illumination of working surface1 (Lux) | Luminance of display1 (Cd/m2) | Luminance of working surface1 (Cd/m2) | Illumination of working surface2 (Lux) | Luminance of display2 (Cd/m2) | Luminance of working surface2 (Cd/m2) | |
|---|---|---|---|---|---|---|---|---|
| Before intervention (first phase) | Day | 302 | 230 | 6.3 | 4.2 | 240 | 7.1 | 5.4 |
| Night | 180 | 153 | 0.16 | 0.12 | 135 | 0.05 | 0.03 | |
| After intervention (second Phase) | Day | 302 | 415 | 15.2 | 12.9 | 426 | 16.2 | 14.8 |
| Night | 180 | 350 | 0.2 | 0.18 | 332 | 0.13 | 0.1 | |
The values of visual performance indicator of Acuity C Test (Ŋ- accuracy C) and visual acuity before and after the intervention
| Time | Before intervention (Median ± IQR) | After intervention (Median ± IQR) | ||
|---|---|---|---|---|
| Parameters | ||||
| 9:00 | Ŋ | 0.33 ± 0.09 | 0.5 ± 0.12 | < 0.001 |
| Visual acuracy ( | 1.62 ± 0.34 | 1.84 ± 0.38 | < 0.001 | |
| 15:00 | Ŋ | 0.22 ± 0.12 | 0.32 ± 0.11 | < 0.001 |
| Visual acuracy ( | 1.31 ± 0.56 | 1.52 ± 0.66 | < 0.001 | |
| 21:00 | Ŋ | 0.33 ± 0.12 | 0.59 ± 0.1 | < 0.001 |
| Visual acuracy ( | 1.20 ± 0.41 | 1.51 ± 0.31 | < 0.001 | |
| 3:00 | Ŋ | 0.25 ± 0.13 | 0.34 ± 0.13 | < 0.001 |
| Visual acuracy ( | 1.02 ± 0.24 | 1.23 ± 0.23 | < 0.001 | |
*Wilcoxon Signed Ranks test
The values of performance indicator of Contrast C test (Ŋ- contrast C) and percentage of contrast before and after the intervention
| Time | Before intervention (Median ± IQR) | After intervention (Median ± IQR) | ||
|---|---|---|---|---|
| Parameters | ||||
| 9:00 | Ŋ | 0.2 ± 0.12 | 0.41 ± 0.12 | < 0.001 |
| Percentage of Contrast (%) | 0.75 ± 0.26 | 0.52 ± 0.25 | < 0.001 | |
| 15:00 | Ŋ | 0.14 ± 0.08 | 0.31 ± 0.09 | < 0.001 |
| Percentage of Contrast (%) | 1.51 ± 0.9 | 1.39 ± 0.88 | < 0.001 | |
| 21:00 | Ŋ | 0.22 ± 0.08 | 0.53 ± 0.08 | < 0.001 |
| Percentage of Contrast (%) | 0.55 ± 0.32 | 0.43 ± 0.31 | < 0.001 | |
| 3:00 | Ŋ | 0.11 ± 0.06 | 0.31 ± 0.07 | < 0.001 |
| Percentage of Contrast (%) | 1.13 ± 0.64 | 1.04 ± 0.64 | < 0.001 | |
*Wilcoxon Signed Ranks test
Comparison of the values of visual performance indicators before and after the intervention
| Before Intervention | 9:00 | 15:00 | 21:00 | 3:00 | ||
| Ŋ-acuity C | 0.33 ± 0.09 | 0.22 ± 0.12 | < 0.001* | 0.33 ± 0.12 | 0.25 ± 0.13 | < 0.001* |
| Visual acuracy ( | 1.62 ± 0.34 | 1.31 ± 0.56 | < 0.001* | 1.20 ± 0.41 | 1.02 ± 0.24 | < 0.001* |
| Ŋ-contrast C | 0.2 ± 0.12 | 0.14 ± 0.08 | < 0.001* | 0.22 ± 0.08 | 0.11 ± 0.06 | < 0.001* |
| Percentage of Contrast (%) | 0.75 ± 0.86 | 1.51 ± 0.9 | < 0.001* | 0.55 ± 0.32 | 1.13 ± 0.64 | < 0.001* |
| After Intervention | 9:00 | 15:00 | 21:00 | 3:00 | ||
| Ŋ-acuity C | 0.5 ± 0.12 | 0.32 ± 0.11 | < 0.001* | 0.59 ± 0.1 | 0.34 ± 0.13 | < 0.001* |
| Visual acuracy ( | 1.84 ± 0.38 | 1.52 ± 0.66 | < 0.001* | 1.51 ± 0.31 | 1.23 ± 0.23 | < 0.001* |
| Ŋ-contrast C | 0.41 ± 0.12 | 0.31 ± 0.09 | < 0.001* | 0.53 ± 0.08 | 0.31 ± 0.07 | < 0.001* |
| Percentage of Contrast (%) | 0.52 ± 0.85 | 1.39 ± 0.88 | < 0.001* | 0.43 ± 0.31 | 1.04 ± 0.64 | < 0.001* |
*Wilcoxon Signed Ranks test