Julia S Sammons1, Erin H Graf2, Sara Townsend3, Cindy L Hoegg3, Sarah A Smathers3, Susan E Coffin4, Katie Williams3, Stephanie L Mitchell5, Ursula Nawab6, David Munson6, Graham Quinn7, Gil Binenbaum7. 1. Division of Infectious Diseases, Perelman School of Medicine at the University of Pennsylvania, Philadelphia, Pennsylvania; Department of Infection Prevention and Control, Children's Hospital of Philadelphia, Philadelphia, Pennsylvania. Electronic address: SAMMONSJ@email.chop.edu. 2. Department of Pathology and Laboratory Medicine, Perelman School of Medicine at the University of Pennsylvania, Philadelphia, Pennsylvania; Infectious Diseases Diagnostics Laboratory, Children's Hospital of Philadelphia, Philadelphia, Pennsylvania. 3. Department of Infection Prevention and Control, Children's Hospital of Philadelphia, Philadelphia, Pennsylvania. 4. Division of Infectious Diseases, Perelman School of Medicine at the University of Pennsylvania, Philadelphia, Pennsylvania; Department of Infection Prevention and Control, Children's Hospital of Philadelphia, Philadelphia, Pennsylvania; Philadelphia Department of Public Health, Philadelphia, Pennsylvania. 5. Clinical Microbiology Laboratory, Children's Hospital of Pittsburgh, University of Pittsburgh School of Medicine, Pittsburgh, Pennsylvania. 6. Division of Neonatology, Perelman School of Medicine at the University of Pennsylvania, Children's Hospital of Philadelphia, Philadelphia, Pennsylvania. 7. Division of Ophthalmology, Perelman School of Medicine at the University of Pennsylvania, Children's Hospital of Philadelphia, Philadelphia, Pennsylvania.
Abstract
PURPOSE: Outbreaks of adenovirus in neonatal intensive care units (NICUs) can lead to widespread transmission and serious adverse outcomes. We describe the investigation, response, and successful containment of an adenovirus outbreak in a NICU associated with contaminated handheld ophthalmologic equipment used during retinopathy of prematurity (ROP) screening. DESIGN: Epidemiologic outbreak investigation. PARTICIPANTS: A total of 23 hospitalized neonates, as well as NICU staff and parents of affected infants. MAIN OUTCOME MEASURES: Routine surveillance identified an adenovirus outbreak in a level IV NICU in August 2016. Epidemiologic investigation followed, including chart review, staff interviews, and observations. Cases were defined as hospital-acquired adenovirus identified from any clinical specimen (NICU patient or employee) or compatible illness in a family member. Real-time polymerase chain reaction (PCR) and partial- and whole-genome sequencing assays were used for testing of clinical and environmental specimens. RESULTS: We identified 23 primary neonatal cases and 9 secondary cases (6 employees and 3 parents). All neonatal case-patients had respiratory symptoms. Of these, 5 developed pneumonia and 12 required increased respiratory support. Less than half (48%) had ocular symptoms. All neonatal case-patients (100%) had undergone a recent ophthalmologic examination, and 54% of neonates undergoing examinations developed adenovirus infection. All affected employees and parents had direct contact with infected neonates. Observations revealed inconsistent disinfection of bedside ophthalmologic equipment and limited glove use. Sampling of 2 handheld lenses and 2 indirect ophthalmoscopes revealed adenovirus serotype 3 DNA on each device. Sequence analysis of 16 neonatal cases, 2 employees, and 2 lenses showed that cases and equipment shared 100% identity across the entire adenovirus genome. Infection control interventions included strict hand hygiene, including glove use; isolation precautions; enhanced cleaning of lenses and ophthalmoscopes between all examinations; and staff furlough. We identified no cases of secondary transmission among neonates. CONCLUSIONS: Adenovirus outbreaks can result from use of contaminated ophthalmologic equipment. Even equipment that does not directly contact patients can facilitate indirect transmission. Patient-to-patient transmission can be prevented with strict infection control measures and equipment cleaning. Ophthalmologists performing inpatient examinations should take measures to avoid adenoviral spread from contaminated handheld equipment.
PURPOSE: Outbreaks of adenovirus in neonatal intensive care units (NICUs) can lead to widespread transmission and serious adverse outcomes. We describe the investigation, response, and successful containment of an adenovirus outbreak in a NICU associated with contaminated handheld ophthalmologic equipment used during retinopathy of prematurity (ROP) screening. DESIGN: Epidemiologic outbreak investigation. PARTICIPANTS: A total of 23 hospitalized neonates, as well as NICU staff and parents of affected infants. MAIN OUTCOME MEASURES: Routine surveillance identified an adenovirus outbreak in a level IV NICU in August 2016. Epidemiologic investigation followed, including chart review, staff interviews, and observations. Cases were defined as hospital-acquired adenovirus identified from any clinical specimen (NICU patient or employee) or compatible illness in a family member. Real-time polymerase chain reaction (PCR) and partial- and whole-genome sequencing assays were used for testing of clinical and environmental specimens. RESULTS: We identified 23 primary neonatal cases and 9 secondary cases (6 employees and 3 parents). All neonatal case-patients had respiratory symptoms. Of these, 5 developed pneumonia and 12 required increased respiratory support. Less than half (48%) had ocular symptoms. All neonatal case-patients (100%) had undergone a recent ophthalmologic examination, and 54% of neonates undergoing examinations developed adenovirus infection. All affected employees and parents had direct contact with infected neonates. Observations revealed inconsistent disinfection of bedside ophthalmologic equipment and limited glove use. Sampling of 2 handheld lenses and 2 indirect ophthalmoscopes revealed adenovirus serotype 3 DNA on each device. Sequence analysis of 16 neonatal cases, 2 employees, and 2 lenses showed that cases and equipment shared 100% identity across the entire adenovirus genome. Infection control interventions included strict hand hygiene, including glove use; isolation precautions; enhanced cleaning of lenses and ophthalmoscopes between all examinations; and staff furlough. We identified no cases of secondary transmission among neonates. CONCLUSIONS:Adenovirus outbreaks can result from use of contaminated ophthalmologic equipment. Even equipment that does not directly contact patients can facilitate indirect transmission. Patient-to-patient transmission can be prevented with strict infection control measures and equipment cleaning. Ophthalmologists performing inpatient examinations should take measures to avoid adenoviral spread from contaminated handheld equipment.
Authors: Ashrafali Mohamed Ismail; Xiaohong Zhou; David W Dyer; Donald Seto; Jaya Rajaiya; James Chodosh Journal: FEBS Lett Date: 2019-12-11 Impact factor: 4.124
Authors: Su-Hsun Liu; Barbara S Hawkins; Sueko M Ng; Mark Ren; Louis Leslie; Genie Han; Irene C Kuo Journal: Cochrane Database Syst Rev Date: 2022-03-03
Authors: Huifeng Fan; Bingtai Lu; Can Cao; Hui Li; Diyuan Yang; Li Huang; Tao Ding; Minhao Wu; Gen Lu Journal: Front Immunol Date: 2021-01-19 Impact factor: 7.561
Authors: Iason S Mantagos; Carolyn Wu; Joseph F Griffith; Benjamin G Jastrzembski; Efren Gonzalez; Samantha Goldstein; Lori Pearlo; Deborah K Vanderveen Journal: J AAPOS Date: 2021-04-18 Impact factor: 1.220