Literature DB >> 30178418

Tri-dimensional model for ventilation tube permeability.

Omer J Ungar1,2, Solomon Dadia3,4, Oron Yahav5,4, Ophir Handzel5,4, Dan M Fliss5,4, Oren Cavel5,4.   

Abstract

PURPOSE: Ventilation tubes (VT) in the tympanic membrane expose the middle ear (ME) to the external auditory canal and its content. It carries the risk of penetration of contaminated material and could provide a pathway for the delivery of drugs into the ME. The aim of this study was to use a printed 3D-model of the external auditory canal (EAC) and ME to assess the permeability of various VTs to different fluids.
METHODS: CT scan of the external and ME was 3D-reconstructed and printed. Five different types of VT were inserted in the model's tympanic membrane and the minimal pressure for penetration to the ME was measured. Liquids with different viscosities, including commonly used ear drops, were tested.
RESULTS: Water passed through the standard 1.14 mm diameter VTs after filling the EAC with a volume of 2 ml and through a narrower grommet or a T-tube after filling the canal with 2.5 ml. Soapy-water had the highest penetration in all VTs (1-2 ml). The initial volume of dexamethasone needed for penetration was 2.5 ml in the standard tubes. It did not pass at any volume through the narrow grommet or the T-tube.
CONCLUSION: In the printed 3D-model, the volume of most solutions, including water, required to provide enough pressure in order to pass through the VTs was as high as the EAC volume or exceeded it. Soapy water had the highest penetrance while Dexamethasone needed volume of 2.5 ml to pass through the VT, questioning its reliability as a passive drug delivery channel to the ME.

Entities:  

Keywords:  Otorrhea; Three-D printing; Ventilation-tubes

Mesh:

Substances:

Year:  2018        PMID: 30178418     DOI: 10.1007/s00405-018-5117-y

Source DB:  PubMed          Journal:  Eur Arch Otorhinolaryngol        ISSN: 0937-4477            Impact factor:   2.503


  9 in total

Review 1.  Should water precautions be recommended for children with tympanostomy tubes?

Authors:  Lyndy J Wilcox; David H Darrow
Journal:  Laryngoscope       Date:  2013-10-15       Impact factor: 3.325

2.  The water penetration of different ventilation tubes.

Authors:  Rupert G Ricks; Rachel Easto; Venkat M Reddy
Journal:  Eur Arch Otorhinolaryngol       Date:  2016-02-22       Impact factor: 2.503

3.  The effect of water exposure after tympanostomy tube insertion.

Authors:  G S Parker; T A Tami; M R Maddox; J F Wilson
Journal:  Am J Otolaryngol       Date:  1994 May-Jun       Impact factor: 1.808

4.  Tympanostomy tubes and liquids--an in vitro study.

Authors:  N R Pashley; P D Scholl
Journal:  J Otolaryngol       Date:  1984-10

5.  Swimming and grommets.

Authors:  N J Marks; R P Mills
Journal:  J R Soc Med       Date:  1983-01       Impact factor: 5.344

6.  Water precautions and tympanostomy tubes: a randomized, controlled trial.

Authors:  Nira A Goldstein; Ellen M Mandel; Marcia Kurs-Lasky; Howard E Rockette; Margaretha L Casselbrant
Journal:  Laryngoscope       Date:  2005-02       Impact factor: 3.325

7.  Clinical practice guideline: Tympanostomy tubes in children.

Authors:  Richard M Rosenfeld; Seth R Schwartz; Melissa A Pynnonen; David E Tunkel; Heather M Hussey; Jeffrey S Fichera; Alison M Grimes; Jesse M Hackell; Melody F Harrison; Helen Haskell; David S Haynes; Tae W Kim; Denis C Lafreniere; Katie LeBlanc; Wendy L Mackey; James L Netterville; Mary E Pipan; Nikhila P Raol; Kenneth G Schellhase
Journal:  Otolaryngol Head Neck Surg       Date:  2013-07       Impact factor: 3.497

8.  Tympanostomy tubes and water exposure: a practical model.

Authors:  R L Hebert; G E King; J P Bent
Journal:  Arch Otolaryngol Head Neck Surg       Date:  1998-10

Review 9.  Water precautions for prevention of infection in children with ventilation tubes (grommets).

Authors:  Daniel Moualed; Liam Masterson; Sanjiv Kumar; Neil Donnelly
Journal:  Cochrane Database Syst Rev       Date:  2016-01-27
  9 in total
  1 in total

1.  Development and validation of a 3D printed antiviral ventilator filter - a comparative study.

Authors:  Ruth Shaylor; Mathew Francis; Esther Shaylor; Solomon Dadia; Barak Cohen
Journal:  BMC Anesthesiol       Date:  2021-04-14       Impact factor: 2.217

  1 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.