Literature DB >> 30170248

A three-dimensional graphene-based ratiometric signal amplification aptasensor for MUC1 detection.

Shaohong Yang1, Feifei Zhang2, Qionglin Liang3, Zonghua Wang4.   

Abstract

A three-dimensional graphene-based ratiometric signal amplification aptasensor for highly sensitive and selective detection of mucin1 (MUC1) by electrochemical method has been developed. Au-reduced graphene oxide (Au-RGO) composite, which was synthesized through hydrothermal reaction and freeze-drying treatment, was used as substrate for fabricating the sensor interface on glassy carbon electrode (GCE). The application of Au-RGO is beneficial for improving electrochemical performance and immobilizing aptamer. Ferrocene labeled aptamer (Fc-Apt), grafting on Au-RGO composite, worked for specific recognition of MUC1 and as internal reference to improve the detection accuracy. Au nanoparticle modified with methyl blue labeled aptamer (MB-Apt@Au) was adopted to combine with MUC1 that captured on the electrode surface to amplify the electrical signal. Under optimal experimental conditions, this sensor was applied to detect a series concentration of MUC1 solution by alternating current voltammetry method. The aptasensor shows satisfactory detection results with a wide linear range of 1 pM to 1 µM, a low detection limit of 0.25 pM and good specificity. The good performance of the prepared electrochemical aptasensor implies that this method has potential for MUC1 detection, and it would be promising for early screening and diagnosis of cancer diseases. The proposed method also lays an important foundation for preparing ratiometric signal amplification aptasensor for other biomarkers detection.
Copyright © 2018 Elsevier B.V. All rights reserved.

Entities:  

Keywords:  Biomarkers detection; Electrochemical method; MUC1 detection; Reduced graphene oxide;Ratiometric aptasensor; Signal amplification

Mesh:

Substances:

Year:  2018        PMID: 30170248     DOI: 10.1016/j.bios.2018.08.036

Source DB:  PubMed          Journal:  Biosens Bioelectron        ISSN: 0956-5663            Impact factor:   10.618


  3 in total

1.  A chemiluminescence resonance energy transfer strategy and its application for detection of platinum ions and cisplatin.

Authors:  Sheng Cai; Ying Zhou; Jiawei Ye; Ruizhe Chen; Lianli Sun; Jianzhong Lu; Cheulhee Jung; Su Zeng
Journal:  Mikrochim Acta       Date:  2019-06-22       Impact factor: 5.833

Review 2.  Electrochemical biosensors for measurement of colorectal cancer biomarkers.

Authors:  Wenxian Zhang; Guangchun Xiao; Jun Chen; Li Wang; Qiongzheng Hu; Jian Wu; Wenhong Zhang; Ming Song; Jinwei Qiao; Chonghai Xu
Journal:  Anal Bioanal Chem       Date:  2021-03-05       Impact factor: 4.142

Review 3.  Ratiometric Electrochemistry: Improving the Robustness, Reproducibility and Reliability of Biosensors.

Authors:  Sam A Spring; Sean Goggins; Christopher G Frost
Journal:  Molecules       Date:  2021-04-07       Impact factor: 4.411

  3 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.