| Literature DB >> 30157835 |
Benjamin J F Dean1,2, Nicholas D Riley3, Earl Robert McCulloch3, Jennifer C E Lane4,3, Amy Beth Touzell5, Alastair J Graham6.
Abstract
BACKGROUND: The aim of this study was to assess the inter observer and intra observer reliability of acute scaphoid fracture classification methods including a novel 'long axis' measurement, a simple method which we have developed with the aim of improving agreement when describing acute fractures.Entities:
Keywords: Acute; Classification; Fracture; Non-union; Scaphoid
Mesh:
Year: 2018 PMID: 30157835 PMCID: PMC6116451 DOI: 10.1186/s12891-018-2236-y
Source DB: PubMed Journal: BMC Musculoskelet Disord ISSN: 1471-2474 Impact factor: 2.362
Fig. 1Plain radiograph with the key points relating to ‘long axis’ measurement marked. Detailed legend - a scaphoid fracture with the distal point (dp), proximal point (pp), the long axis line, the fracture line, a line perpendicular to the long axis, and the radial and ulnar lines
Fig. 2Plain radiograph of a scaphoid fracture demonstrating the measurements made. Detailed legend - the long axis (l) and the distance along the long axis to the fracture site are shown (f, fracture distance), while the ulnar (u) and radial (r) distances to the fracture site are also shown. Note (f) is measured along (l) but for ease of demonstrating the methodology (f) has been moved just adjacent to (l). In this example the long axis measurement is f/l which equals 0.28
Patient demographics and injury details
| Centre 1 | Centre 2 | |
|---|---|---|
| Patient number | 30 | 30 |
| Age | 31.4 (11.3) | 29 (13.9) |
| Sex | 27 M/3 F | 25 M/5 F |
| Median time from injury to Xrays in days (IQR) | 0 (0–7) | 0 (0–5) |
| Median time from injury to CT in days (IQR) | 6.5 (5–13) | 12.5 (6.5–21) |
Inter observer reliability of the X-ray based measurements
| System | Centre 1 | Centre 2 | Overall mean |
|---|---|---|---|
| Russe | 0.131 | 0.120 | 0.126 |
| Herbert | 0.345 | 0.386 | 0.366 |
| Mayo | 0.609 | 0.522 | 0.566 |
| Long axis | 0.732 | 0.784 | 0.758 |
| Sagittal deformity | −0.02 | 0.0167 | 0.00 |
| Coronal deformity | 0.425 | 0.438 | 0.432 |
| Comminution | 0.410 | 0.529 | 0.470 |
| Scapholunate angle | 0.389 | 0.580 | 0.485 |
Fig. 3Scatter plot depicting the reliability of the ‘long axis’ measurement in comparison with the more established classification systems. Detailed legend – this demonstrates the reliability of the Russe, Herbert, Mayo and long axis systems. As tested using Bonferroni’s multiple comparison test the long axis measurement system was significantly more reliable than the Mayo (p < 0.01), the Herbert (p < 0.001) and the Russe (p < 0.001) classification systems
Inter observer reliability of the CT based measurements
| System | Centre 1 | Centre 2 | Overall mean |
|---|---|---|---|
| Russe | 0.085 | 0.055 | 0.070 |
| Herbert | 0.389 | 0.308 | 0.348 |
| Mayo | 0.531 | 0.553 | 0.542 |
| Long axis | 0.715 | 0.686 | 0.701 |
| Sagittal deformity | 0.210 | 0.192 | 0.201 |
| Coronal deformity | 0.212 | 0.240 | 0.226 |
| Comminution | 0.328 | 0.722 | 0.525 |
The degree of agreement between X-ray and CT based measurements
| System | Centre 1 | Centre 2 | Overall mean |
|---|---|---|---|
| Russe | 0.027 | 0.407 | 0.217 |
| Herbert | 0.506 | 0.676 | 0.591 |
| Mayo | 0.778 | 0.799 | 0.788 |
| Long axis | 0.594 | 0.548 | 0.571 |
| Sagittal deformity | 0.251 | 0.274 | 0.262 |
| Coronal deformity | 0.339 | 0.355 | 0.347 |
| Comminution | 0.436 | 0.325 | 0.381 |
Intra observer reliability of the X-ray and CT based measurements: the ‘long axis’ measurement versus established classification systems.
| System | Xray | CT |
|---|---|---|
| Russe | 0.583 | 0.550 |
| Herbert | 0.694 | 0.839 |
| Mayo | 0.824 | 0.855 |
| Long axis | 0.895 | 0.889 |
Xray based reliability
| Centre 1 | Centre 2 | Overall mean | |||||||
|---|---|---|---|---|---|---|---|---|---|
| 1 vs 2 | 1 vs 3 | 2 vs 3 | Mean | 1 vs 2 | 1 vs 3 | 2 vs 3 | Mean | ||
| Russe reliability (Kappa) | 0.317 | 0.021 | 0.056 | 0.131 | 0.171 | 0.058 | 0.132 | 0.120 | 0.126 |
| Herbert reliability (kappa) | 0.289 | 0.289 | 0.457 | 0.345 | 0.424 | 0.426 | 0.308 | 0.386 | 0.366 |
| Mayo reliability (kappa) | 0.665 | 0.615 | 0.548 | 0.609 | 0.607 | 0.459 | 0.500 | 0.522 | 0.566 |
| Central distance reliability (ICC) | 0.713(0.832) | 0.803(0.891) | 0.687(0.815) | 0.732(0.891) | 0.688(0.815) | 0.768(0.869) | 0.878(0.935) | 0.784(0.916) | 0.758(0.904) |
| Ulnar distance reliability(ICC) | 0.657(0.793) | 0.857(0.923) | 0.650(0.788) | 0.709(0.880) | 0.664(0.798) | 0.359(0.528) | 0.765(0.867) | 0.590 (0.812) | 0.650(0.846) |
| Radial distance reliability(ICC) | 0.656(0.792) | 0.785(0.880) | 0.708(0.829) | 0.716(0.883) | 0.581(0.735) | 0.600(0.750) | 0.385(0.556) | 0.523(0.767) | 0.620(0.825) |
| Sagittal deformity reliability(kappa) | −0.119 | 0.118 | −0.05 | −0.02 | −0.061 | 0.048 | 0.063 | 0.0167 | 0.00 |
| Coronal deformity reliability(kappa) | 0.333 | 0.250 | 0.692 | 0.425 | 0.659 | 0.328 | 0.328 | 0.438 | 0.432 |
| Comminution deformity reliability(kappa) | 0.268 | 0.514 | 0.447 | 0.410 | 0.561 | 0.615 | 0.412 | 0.529 | 0.470 |
| SL angle reliabilityICC) | 0.331(0.498) | 0.422(0.594 | 0.435(0.607) | 0.389(0.656) | 0.688(0.815) | 0.449(0.620) | 0.629(0.773) | 0.580(0.806) | 0.485(0.731) |
CT based reliability
| Centre 1 | Centre 2 | Overall mean | |||||||
|---|---|---|---|---|---|---|---|---|---|
| 1 vs 2 | 1 vs 3 | 2 vs 3 | Mean | 1 vs 2 | 1 vs 3 | 2 vs 3 | Mean | ||
| Russe reliability(Kappa) | 0.00 | 0.253 | 0.00 | 0.084 | 0.066 | 0.056 | 0.156 | 0.055 | 0.070 |
| Herbert reliability(kappa) | 0.464 | 0.389 | 0.314 | 0.389 | 0.271 | 0.425 | 0.227 | 0.308 | 0.348 |
| Mayo reliability(kappa) | 0.562 | 0.568 | 0.463 | 0.531 | 0.717 | 0.462 | 0.481 | 0.553 | 0.542 |
| Central distance reliability(ICC) | 0.748(0.856) | 0.687(0.814) | 0.701(0.825) | 0.715(0.883) | 0.636(0.717) | 0.569(0.725) | 0.600(0.750) | 0.686(0.867) | 0.701(0.875) |
| Ulnar distance reliability(ICC) | 0.667(0.800) | 0.664(0.798) | 0.476(0.645) | 0.598(0.817) | 0.400(0.572) | 0.359(0.528) | 0.178(0.302) | 0.307(0.571) | 0.453(0.694) |
| Radial distance reliability(ICC) | 0.650(0.788) | 0.717(0.835) | 0.569(0.725) | 0.644(0.844) | 0.455(0.625) | 0.596(0.747) | 0.224(0.366) | 0.437(0.699) | 0.541(0.772) |
| Sagittal deformity reliability(kappa) | 0.400 | 0.067 | 0.163 | 0.21 | 0.366 | 0.098 | 0.112 | 0.192 | 0.201 |
| Coronal deformity reliability(kappa) | 0.268 | 0.118 | 0.250 | 0.212 | 0.420 | 0.189 | 0.112 | 0.240 | 0.226 |
| Comminution deformity reliability(kappa) | 0.279 | 0.279 | 0.426 | 0.328 | 0.684 | 0.815 | 0.667 | 0.722 | 0.525 |
Xray versus CT reliability
| Centre 1 | Centre 2 | Overall mean | |||||||
|---|---|---|---|---|---|---|---|---|---|
| 1 | 2 | 3 | Mean | 1 | 2 | 3 | Mean | ||
| Russe reliability(Kappa) | 0.00 | 0.00 | 0.082 | 0.027 | 0.054 | 0.224 | 0.944 | 0.407 | 0.217 |
| Herbert reliability(kappa) | 0.705 | 0.412 | 0.402 | 0.506 | 0.544 | 0.586 | 0.898 | 0.676 | 0.591 |
| Mayo reliability(kappa) | 0.918 | 0.627 | 0.790 | 0.778 | 0.904 | 0.804 | 0.688 | 0.799 | 0.788 |
| Central distance reliability(ICC) | 0.724(0.840) | 0.464(0.634) | 0.593(0.744) | 0.594(0.739) | 0.767(0.868) | 0.427(0.599) | 0.451(0.621) | 0.548(0.696) | 0.571(0.718) |
| Ulnar distance reliability(ICC) | 0.826(0.905) | 0.349(0.517) | 0.573(0.728) | 0.583(0.717) | 0.449(0.620) | 0.465(0.635) | 0.161(0.278) | 0.358(0.511) | 0.471(0.614) |
| Radial distance reliability(ICC) | 0.719(0.837) | 0.467(0.637) | 0.784(0.879) | 0.657(0.784) | 0.751(0.858) | 0.393(0.565) | 0.271(0.427) | 0.472(0.617) | 0.565(0.700) |
| Sagittal deformity reliability(kappa) | 0.267 | 0.217 | 0.270 | 0.251 | 0.405 | 0.05 | 0.366 | 0.274 | 0.262 |
| Coronal deformity reliability(kappa) | 0.634 | 0.333 | 0.050 | 0.339 | 0.189 | 0.772 | 0.105 | 0.355 | 0.347 |
| Comminution deformity reliability(kappa) | 0.298 | 0.585 | 0.426 | 0.436 | 0.815 | 0.615 | 0.359 | 0.325 | 0.381 |
Inter observer reliability for X-ray and CT based assessments
| Observer 1 | Observer 2 | Mean | ||||
|---|---|---|---|---|---|---|
| X-ray | CT | X-ray | CT | X-ray | CT | |
| Russe reliability(Kappa) | 0.628 | 0.679 | 0.538 | 0.420 | 0.583 | 0.550 |
| Herbert reliability(kappa) | 0.749 | 0.850 | 0.639 | 0.828 | 0.694 | 0.839 |
| Mayo reliability(kappa) | 0.831 | 0.838 | 0.817 | 0.871 | 0.824 | 0.855 |
| Central distance reliability(ICC) | 0.905(0.950) | 0.900(0.948) | 0.884(0.938) | 0.878(0.935) | 0.895(0.944) | 0.889(0.946) |
| Ulnar distance reliability(ICC) | 0.820(0.901) | 0.920(0.958) | 0.568(0.725) | 0.839(0.912) | 0.694(0.813) | 0.807(0.890) |
| Radial distance reliability(ICC) | 0.822(0.902) | 0.931(0.964) | 0.850(0.919) | 0.755(0.860) | 0.836(0.911) | 0.843(0.912) |
| Sagittal deformity reliability(kappa) | 0.765 | 0.891 | 0.612 | 0.636 | 0.689 | 0.764 |
| Coronal deformity reliability(kappa) | 0.818 | 0.826 | 0.433 | 0.622 | 0.626 | 0.724 |
| Comminution deformity reliability(kappa) | 0.774 | 0.840 | 0.689 | 0.944 | 0.732 | 0.892 |