Effects of Sodium Hypochlorite Concentration and Temperature on the Cyclic Fatigue Resistance of Heat-treated Nickel-titanium Rotary Instruments.

Hussam Alfawaz1, Abdullah Alqedairi2, Hala Alsharekh2, Eman Almuzaini2, Shahd Alzahrani2, Ahmed Jamleh3.   

Abstract

INTRODUCTION: We tested the cyclic fatigue resistance of heat-treated instruments immersed in sodium hypochlorite solution under different concentrations and temperature conditions.
METHODS: Based on the irrigating solution's concentration and temperature, 135 ProTaper Gold (PTG; Dentsply Sirona, York, PA) F2 instruments were divided equally into 9 groups of 15. Cyclic fatigue testing was performed by using a block with artificial canals with a curvature angle of 60°, a curvature radius of 5 mm, and a curvature center 5 mm from the instrument tip. The block was fixed inside a water bath of distilled water, 2.5% sodium hypochlorite (NaOCl), or 5.25% NaOCl. The temperature was preset at 25°C, 37°C, or 60°C. The instrument was rotated at 300 rpm until fracturing occurred. The number of cycles to fracture was calculated, and the fragment length was measured. Fractured surfaces were examined via scanning electron microscopy. NCF data were analyzed statistically via Kruskal-Wallis and Mann-Whitney tests. All statistical analyses were performed using SPSS software Version 22 (IBM Corp, Armonk, NY) at a 5% significance level.
RESULTS: The number of cycles to fracture of the PTG F2 was highest in distilled water at 25°C and lowest in 5.25% NaOCl at 60°C. Changing the irrigating solution from distilled water to NaOCl and increasing the surrounding temperature reduced the fatigue resistance.
CONCLUSIONS: NaOCl irrigating solution at different concentrations and temperatures influenced the cyclic fatigue resistance of PTG instruments. Future NiTi instrument failure studies should be conducted under simulated body temperature conditions in commonly used irrigating solutions.
Copyright © 2018 American Association of Endodontists. Published by Elsevier Inc. All rights reserved.

Entities:  

Keywords:  Concentration; ProTaper Gold; cyclic fatigue resistance; heat-treated file; sodium hypochlorite; temperature

Mesh:

Substances:

Year:  2018        PMID: 30154007     DOI: 10.1016/j.joen.2018.07.009

Source DB:  PubMed          Journal:  J Endod        ISSN: 0099-2399            Impact factor:   4.171


  8 in total

1.  Comparison of the cyclic fatigue resistance of VDW.ROTATE, TruNatomy, 2Shape, and HyFlex CM nickel-titanium rotary files at body temperature.

Authors:  Mustafa Gündoğar; Gülşah Uslu; Taha Özyürek; Gianluca Plotino
Journal:  Restor Dent Endod       Date:  2020-06-22

2.  Resistance to Cyclic Fatigue of Nickel-Titanium Files Immersed in Sodium Hypochlorite at Body Temperature.

Authors:  Hind F Abuhulaibah; Ammar AbuMostafa
Journal:  Int J Dent       Date:  2020-09-19

3.  Effect of NaOCl and EDTA irrigating solutions on the cyclic fatigue resistance of EdgeTaper Platinum instruments.

Authors:  Hussam Alfawaz; Abdullah Alqedairi; Maha Alhamdan; Najla Alkhzim; Shatha Alfarraj; Ahmed Jamleh
Journal:  BMC Oral Health       Date:  2022-05-22       Impact factor: 3.747

4.  Effect of immersion in sodium hypochlorite on the cyclic fatigue resistance of three rotary instruments.

Authors:  Daiane Nogueira; Carlos Eduardo Da Silveira Bueno; Augusto Shoji Kato; Alexandre Sigrist De Martin; Rina Andréa Pelegrine; Ana Grasiela Da Silva Limoeiro; Daniel Guimarães Pedro Rocha; Carlos Eduardo Fontana
Journal:  J Conserv Dent       Date:  2021-02-11

5.  Evidence for reduced torsional resistance of rotary files under curved position.

Authors:  Ahmed Jamleh; Raghad Almedlej; Rasha Alomar; Nouf Almayouf; Abdulmohsen Alfadley; Khalid Alfouzan
Journal:  Saudi Dent J       Date:  2020-08-06

6.  Influence of Sodium Hypochlorite and Chlorhexidine on the Dynamic Cyclic Fatigue Resistance of XP Endo Shaper Instruments.

Authors:  Alexandra Aparecida Tanomaru; Ana Grasiela Limoeiro; Adriana de Jesus Soares; Elson Lopes Medeiros Junior; Gabriel Rocha Campos; Sílvia Kaoru Hamasaki; Wayne Martins Nascimento; Luiz Meton Horta; Paula Avelar da Silva Ribeiro Goulart; Viviane Rangel do Couto; Patrícia Bastos Alves; Verônica Magalhães; Danilo De Luca Campos; Marcos Frozoni
Journal:  Eur J Dent       Date:  2021-12-22

Review 7.  Effect of body temperature on the cyclic fatigue resistance of the nickel-titanium endodontic instruments: A systematic review and meta-analysis of in vitro studies.

Authors:  Selventhra Savitha; Sidhartha Sharma; Vijay Kumar; Amrita Chawla; Perumal Vanamail; Ajay Logani
Journal:  J Conserv Dent       Date:  2022-08-02

8.  Factors influencing incidents of complications while using nickel-titanium rotary instruments for root canal treatment.

Authors:  Ahmad A Madarati
Journal:  BMC Oral Health       Date:  2019-11-11       Impact factor: 2.757

  8 in total