| Literature DB >> 30151277 |
F Cifariello1,2, M Minicucci3, F Di Renzo1, D Di Taranto1, G Coclite1, S Zaccaria1, S De Turris1, C Costagliola1,2,3.
Abstract
AIM: To evaluate two different techniques of cross-linking: standard epithelium-off (CXL epi-off) versus transepithelial (CXL epi-on) cross-linking in patient with progressive keratoconus.Entities:
Year: 2018 PMID: 30151277 PMCID: PMC6087595 DOI: 10.1155/2018/4947983
Source DB: PubMed Journal: J Ophthalmol ISSN: 2090-004X Impact factor: 1.909
Group 1 (epi-off): comparison of analyzed parameters (mean ± SD) before and after treatment at the end of the follow-up (2 years).
| Preoperative | Postoperative |
| |
|---|---|---|---|
| Mean corneal thickness ( | 556.45 ± 23.56 | 501.41 ± 21.91 | 0.01 |
|
| 44.62 ± 2.63 | 44.71 ± 3.03 | 0.33 |
|
| 47.75 ± 3.20 | 47.76 ± 3.47 | 0.10 |
| Mean | 46.19 ± 2.82 | 46.16 ± 3.15 | 0.57 |
| BCVA (logMAR) | 0.36 ± 0.14 | 0.22 ± 0.12 | 0.01 |
| OSDI© (before and one-month later) | 4.85 ± 1.18 | 13.56 ± 2.15 | 0.01 |
BCVA: best corrected visual acuity; OSDI: Ocular Surface Disease Index; Student's t-test for paired values.
Group 2 (epi-on): comparison of analyzed parameters (mean ± SD) before and after treatment at the end of the follow-up (2 years).
| Preoperative | Postoperative |
| |
|---|---|---|---|
| Mean corneal thickness ( | 565.41 ± 31.91 | 495.45 ± 43.16 | 0.01 |
|
| 45.84 ± 2.53 | 46.44 ± 3.67 | 0.25 |
|
| 48.86 ± 3.27 | 49.75 ± 3.47 | 0.60 |
| Mean | 47.00 ± 2.79 | 47.82 ± 4.06 | 0.10 |
| BCVA (logMAR) | 0.32 ± 0.16 | 0.27 ± 0.13 | 0.01 |
| OSDI© (before and one-month later) | 4.98 ± 1.32 | 11.26 ± 2.12 | 0.04 |
BCVA: best corrected visual acuity; OSDI: Ocular Surface Disease Index; Student's t-test for paired values.
Epi-off versus epi-on after 2-year follow-up (mean ± SD).
| Epi-off | Epi-on |
| |
|---|---|---|---|
| Mean corneal thickness ( | 501.41 ± 21.91 | 495.45 ± 43.16 | 0.10 |
|
| 44.71 ± 3.03 | 46.44 ± 3.67 | 0.01 |
|
| 47.76 ± 3.47 | 49.75 ± 3.47 | 0.01 |
| Mean | 46.16 ± 3.15 | 47.82 ± 4.06 | 0.08 |
| BCVA (logMAR) | 0.22 ± 0.12 | 0.27 ± 0.13 | 0.01 |
| OSDI© (before and one-month later) | 13.56 ± 2.15 | 11.26 ± 2.12 | 0.02 |
BCVA: best corrected visual acuity; OSDI: Ocular Surface Disease Index; Student's t-test for paired values.
Ocular Surface Disease Index (OSDI©).
| All of the time | Most of the time | Half of the time | Some of the time | None of the time | |
|---|---|---|---|---|---|
|
| |||||
| (1) Eyes that are sensitive to light? | 4 | 3 | 2 | 1 | 0 |
| (2) Eyes that feel gritty? | 4 | 3 | 2 | 1 | 0 |
| (3) Painful or sore eyes? | 4 | 3 | 2 | 1 | 0 |
| (4) Blurred vision? | 4 | 3 | 2 | 1 | 0 |
| (5) Poor vision? | 4 | 3 | 2 | 1 | 0 |
| Subtotal | Score | A | |||
|
| |||||
|
| |||||
| (6) Reading | 4 | 3 | 2 | 1 | 0 |
| (7) Driving at night? | 4 | 3 | 2 | 1 | 0 |
| (8) Working with a computer or bank machine (ATM)? | 4 | 3 | 2 | 1 | 0 |
| (9) Watching TV? | 4 | 3 | 2 | 1 | 0 |
| Subtotal | Score | B | |||
|
| |||||
|
| |||||
| (10) Windy conditions? | 4 | 3 | 2 | 1 | 0 |
| (11) Places or areas with low humidity (very dry)? | 4 | 3 | 2 | 1 | 0 |
| (12) Areas that are air conditioned? | 4 | 3 | 2 | 1 | 0 |
| Subtotal | Score | C | |||
Add subtotals A, B, and C to obtain the result.
Postoperative confocal microscopy in epi-off versus epi-on patients after 2-year follow-up.
| Epi-off (%) | Epi-on (%) |
| |
|---|---|---|---|
| Corneal nerve alteration | 93.80 | 87.50 | Not significant |
| Fibrotic reaction | 43.75 | 25.00 | <0.01 |
| Alterated keratocyte | 62.50 | 18.75 | <0.001 |
Chi-square test for nonparametric variables.