Zhenyu Yun1, Lian Zeng2, Weijian Huang3, Qi Wu1, Yiling Fan4, Shigang Zheng5, Liping Peng6, Jiayu Han2, Ying Huang2, Hang Zhou2, Haodong Chen7. 1. China National Institute of Standardization, #4 Zhichun Rd., Haidian District, Beijing, 100088, China. 2. Sichuan Hua Hansan Bio Technology Co., Ltd., #88, Keyuan South Rd., Chengdu, 610041, China. 3. Chengdu CapitalBio Technology Co., Ltd., # 88, Bayi Rd., Chengdu, 610041, China. 4. Shanghai Institute for Food and Drug Control, Shanghai, 201203, China. 5. Chengdu Institute of Biology, Chinese Academy of Sciences, #9, Section 4, Renmin South Rd., Chengdu, 610041, China. 6. National Center of Agriculture Standardization Monitoring and Researching, #1218 Chuangxin 2nd Rd., Songbei science and technology District, Harbin, 150028, China. 7. Sichuan Hua Hansan Bio Technology Co., Ltd., #88, Keyuan South Rd., Chengdu, 610041, China. chenhaodong301@163.com.
Abstract
Diarrheagenic Escherichia coli (DEC) causes human diarrhea symptom in both healthy and immunocompromised individuals. An auto-microfluidic thin-film chip (AMTC) instrument integrating one-step multiplex PCR (mPCR) with reverse dot blot hybridization (RDBH) was developed for high-throughput detection of DEC. The novel mPCR method was developed by designing 14 specific primers and corresponding probes. 14 indexes including an endogenous gene (uidA) and 13 pathogenic genes (stx1, stx2, escV, ipaH, invE, estB, lt, pic, aggR, astA, bfpB, sth and stp) of DEC were detected. This one-step mPCR + RDBH approach is useful for simultaneous detection of numerous target genes in a single sample, whose specificity and availability have been confirmed on the positive control of 11 DEC strains. In addition, with 300 diarrheal stool samples being detected by this method, 21 were found to contain five major DEC strains. Compared with monoplex PCR and previous one-step mPCR approach, this method could detect ipaH and estB, and compared with current commercial kit, the relevance ratio of DEC detected by the AMTC method was increased by 1% in stool samples. Furthermore, the novel integration AMTC device could be a valuable detection tool for categorization of E. coli.
Diarrheagenic Escherichia coli (DEC) causes humandiarrhea symptom in both healthy and immunocompromised individuals. An auto-microfluidic thin-film chip (AMTC) instrument integrating one-step multiplex PCR (mPCR) with reverse dot blot hybridization (RDBH) was developed for high-throughput detection of DEC. The novel mPCR method was developed by designing 14 specific primers and corresponding probes. 14 indexes including an endogenous gene (uidA) and 13 pathogenic genes (stx1, stx2, escV, ipaH, invE, estB, lt, pic, aggR, astA, bfpB, sth and stp) of DEC were detected. This one-step mPCR + RDBH approach is useful for simultaneous detection of numerous target genes in a single sample, whose specificity and availability have been confirmed on the positive control of 11 DEC strains. In addition, with 300 diarrheal stool samples being detected by this method, 21 were found to contain five major DEC strains. Compared with monoplex PCR and previous one-step mPCR approach, this method could detect ipaH and estB, and compared with current commercial kit, the relevance ratio of DEC detected by the AMTC method was increased by 1% in stool samples. Furthermore, the novel integration AMTC device could be a valuable detection tool for categorization of E. coli.
Most E. coli strains are normal inhabitants of the human intestinal tract. Some strains have acquired virulence genes that confer pathogenicity and are clarified as DEC[1]. The major virulence factors are essential for the study of the epidemiology and pathogenicity of DEC infection, such as severe diarrhea, food poisoning and similar outbreaks worldwide. Infections with these kinds of pathogens have therefore aroused increasing concern in the clinical diagnosis of diarrheal disease in recent years. These virulent organisms can be classified into five major categories on the basis of the nature of their infections and pathogenic mechanisms[2-4], namely, enterohemorrhagic E. coli (EHEC), enteropathogenic E. coli (EPEC), enteroinvasive E. coli (EIEC), enteroaggregative E. coli (EAEC), and enterotoxigenic E. coli (ETEC). However, current rates of infections by these important enteric pathogens are probably underestimated to a great extent, because the existing clinical diagnostic methods are unable to distinguish them from normal nonpathogenic flora. To achieve the goal of epidemic prevention and control of DEC, a more reliable procedure is required to identify and categorize DEC isolates.Many clinical laboratories routinely perform only serotyping assays aiming at detection of DEC. By using primers of virulence genes, the current monoplex PCR or multiplex PCR assay offers the possibility of rapid diagnosis of DEC strains[5,6]. Nevertheless, screening of bacterial isolates for DEC strains requires a large number of individual PCR assays when single primer sets are used[7]. Qualitative detection of DEC is performed by the agarose gelelectrophoresis based on various distributions of different sizes of amplified fragments. So, the number of fragments that can be detected is limited, and the bands of small fragments cannot be recognized very well. Besides, some genes recently reported in the study of the epidemiology and pathogenicity of DEC infection, such as ipaH and estB[8,9], were not included in the detection by these methods. Accordingly, it is particularly important and urgent to improve the DEC detection methods.Recently, one-step mPCR finds wide application in categorization and detection of some bacterial strains[10,11], and it has been used in some commercial kits as well. This newly-developed method avoids the abundant repeats of individual PCR assays, so it is unnecessary to consider the size of the fragments of PCR products. Moreover, one-step mPCR and RDBH can be combined together with AMTC device[12]. The AMTC method shows some advantages on detection of DEC strains, such as increased test capacity, added indexes like ipaH and estB, quickened detection, and improved accuracy of detection.In this study, 14 specific primers were designed to form one-step multiplex PCR of a newly developed kit, and 14 specific probes were designed accordingly. As shown in Fig. 1A, a square nylon thin-film was divided into 16 small areas using lines. The probes were immobilized on different areas of the square nylon thin-film in line with the surface design in Fig. 1B. Together with the AMTC device, qualitative detection of DEC was successfully established. Further, DEC strains in 300 diarrheal stool samples were detected using the AMTC method.
Figure 1
Design of microfluidic thin-film chip. (A) Overview of microfluidic thin-film chip. (B) Arrangement of DEC probes on the thin-film-based array. uidA, β-glucuronidase gene; stx (stx1, stx2), shiga-like toxin I (stx1), shiga-like toxin II (stx2); escV, gene encoding LEE (locus of enterocyte effacement)-encoded type III secretion system factor; ipaH, invasive plasmid antigen H-gene; invE, invasive plasmid regulator; estB, heat-stable enterotoxin b; lt, heat-labile enterotoxin; bfpB, bundle-forming pilus B; pic, protein involved in intestinal colonization; aggR, aggregative adhesive fimbriae regulator; astA, enteroaggregative heat-stable enterotoxin A; sth, heat-stable enterotoxins initially discovered in the isolates from human; stp, heat-stable enterotoxins initially discovered in the isolates from pigs; PC, positive control; and NC, negative control.
Design of microfluidic thin-film chip. (A) Overview of microfluidic thin-film chip. (B) Arrangement of DEC probes on the thin-film-based array. uidA, β-glucuronidase gene; stx (stx1, stx2), shiga-like toxin I (stx1), shiga-like toxin II (stx2); escV, gene encoding LEE (locus of enterocyte effacement)-encoded type III secretion system factor; ipaH, invasive plasmid antigen H-gene; invE, invasive plasmid regulator; estB, heat-stable enterotoxin b; lt, heat-labile enterotoxin; bfpB, bundle-forming pilus B; pic, protein involved in intestinal colonization; aggR, aggregative adhesive fimbriae regulator; astA, enteroaggregative heat-stable enterotoxin A; sth, heat-stable enterotoxins initially discovered in the isolates from human; stp, heat-stable enterotoxins initially discovered in the isolates from pigs; PC, positive control; and NC, negative control.
Results
Detection of DEC Strains by Monoplex PCR and Electrophoresis
By using the specific primers listed in China National Standard (GB 4789.6-2016), the collected DEC strains were identified by monoplex PCR. As shown in Fig. 2, 9 strains were identified positively in 11 DEC strains. BP01 was identified as EHEC; BP02 and BP03 were identified as EIEC; BP04 was identified as atypical EPEC; BP05 was identified as typical EPEC; BP08 and BP09 were identified as ETEC; BP10 and BP11 were identified as EAEC; and BP06 and BP07 were identified as E. coli (Supplementary Fig. S1).
Figure 2
Electrophoretograms of monoplex PCR for DEC strains. BP01 includes uidA, stx1, stx2, escV and astA, being identified as EHEC; BP02 includes uidA and ipaH, identified as EIEC; BP03 includes uidA, ipaH, invE and pic, identified as EIEC; BP04 includes uidA and escV, identified as atypical EPEC; BP05 includes uidA, escV and bfpB, identified as typical EPEC; BP06 and BP07 include uidA, but no virulence genes; BP08 includes uidA, lt and stp, identified as ETEC; BP09 includes uidA, lt, astA and sth, identified as ETEC; BP10 includes uidA, pic and aggR, identified as EAEC; and BP11 includes uidA, pic, aggR and astA, identified as EAEC.
Electrophoretograms of monoplex PCR for DEC strains. BP01 includes uidA, stx1, stx2, escV and astA, being identified as EHEC; BP02 includes uidA and ipaH, identified as EIEC; BP03 includes uidA, ipaH, invE and pic, identified as EIEC; BP04 includes uidA and escV, identified as atypical EPEC; BP05 includes uidA, escV and bfpB, identified as typical EPEC; BP06 and BP07 include uidA, but no virulence genes; BP08 includes uidA, lt and stp, identified as ETEC; BP09 includes uidA, lt, astA and sth, identified as ETEC; BP10 includes uidA, pic and aggR, identified as EAEC; and BP11 includes uidA, pic, aggR and astA, identified as EAEC.
Detection of DEC Strains by Previous One-step mPCR and Electrophoresis
The above mentioned eleven DEC strains were also detected by a commercial kit, in which one-step mPCR and electrophoresis were mainly used. As shown in Fig. 3, BP01 was identified as EHEC; BP03 was identified as EIEC; BP04 was identified as atypical EPEC; BP05 was identified as typical EPEC; BP08 and BP09 were identified as ETEC; BP10 and BP11 were identified as EAEC; and BP02, BP06 and BP07 were identified as E. coli. Some E. coli strains, positive and negative controls were identified (Supplementary Fig. S2).
Figure 3
Electrophoretogram of one-step mPCR for DEC strains. BP01 includes uidA, stx1, stx2, escV and astA, being identified as EHEC; BP02 includes uidA, but no virulence genes; BP03 includes uidA, invE and pic, identified as EIEC; BP04 includes uidA and escV, identified as atypical EPEC; BP05 includes uidA, escV and bfpB, identified as typical EPEC; BP06 and BP07 include uidA, but no virulence genes; BP08 includes uidA, lt and stp, identified as ETEC; BP09 includes uidA, lt, astA and sth, identified as ETEC; BP10 includes uidA, pic and aggR, identified as EAEC; and BP11 includes uidA, pic, aggR and astA, identified as EAEC.
Electrophoretogram of one-step mPCR for DEC strains. BP01 includes uidA, stx1, stx2, escV and astA, being identified as EHEC; BP02 includes uidA, but no virulence genes; BP03 includes uidA, invE and pic, identified as EIEC; BP04 includes uidA and escV, identified as atypical EPEC; BP05 includes uidA, escV and bfpB, identified as typical EPEC; BP06 and BP07 include uidA, but no virulence genes; BP08 includes uidA, lt and stp, identified as ETEC; BP09 includes uidA, lt, astA and sth, identified as ETEC; BP10 includes uidA, pic and aggR, identified as EAEC; and BP11 includes uidA, pic, aggR and astA, identified as EAEC.
Detection of DEC Strains by the Novel One-step mPCR + RDBH
The detection results of DEC strains by a novel one-step mPCR + RDBH method on AMTC instrument are shown in Fig. 4. BP01 was identified as EHEC; BP02 and BP03 were identified as EIEC; BP04 was identified as atypical EPEC; BP05 was identified as typical EPEC; BP06, BP08 and BP09 were identified as ETEC; and BP10 and BP11 were identified as EAEC; only BP07 was identified as E. coli.
Figure 4
Qualitative detection of DEC strains. BP01 includes uidA, stx1, stx2, escV and astA, being identified as EHEC; BP02 includes uidA and ipaH, identified as EIEC; BP03 includes uidA, ipaH, invE and pic, identified as EIEC; BP04 includes uidA and escV, identified as atypical EPEC; BP05 includes uidA, escV and bfpB, identified as typical EPEC; BP06 includes uidA and estB, identified as ETEC; BP07 includes uidA, but no virulence genes; BP08 includes uidA, lt and stp, identified as ETEC; BP09 includes uidA, lt, astA and sth, identified as ETEC; BP10 includes uidA, pic and aggR, identified as EAEC; BP11 includes uidA, pic, aggR and astA, identified as EAEC.
Qualitative detection of DEC strains. BP01 includes uidA, stx1, stx2, escV and astA, being identified as EHEC; BP02 includes uidA and ipaH, identified as EIEC; BP03 includes uidA, ipaH, invE and pic, identified as EIEC; BP04 includes uidA and escV, identified as atypical EPEC; BP05 includes uidA, escV and bfpB, identified as typical EPEC; BP06 includes uidA and estB, identified as ETEC; BP07 includes uidA, but no virulence genes; BP08 includes uidA, lt and stp, identified as ETEC; BP09 includes uidA, lt, astA and sth, identified as ETEC; BP10 includes uidA, pic and aggR, identified as EAEC; BP11 includes uidA, pic, aggR and astA, identified as EAEC.
Detection of Other Diarrhea Related Strains by the Novel One-step mPCR + RDBH
To test the specificity of the novel one-step mPCR + RDBH method on the AMTC instrument, it was also used to test diarrhea-related strains different from E. coli. Salmonella enteric (CICC 21493), Vibrio parahaemolyticus (CICC 21617), Campylobacter jejuni (CICC 22936) and Vibrio cholera (CICC 23794) could not be detected by any of the AMTC indexes. Only Shigella flexneri (CICC 21534) and Shigella sonnei (CICC 21535) could be detected at the site of uidA and ipaH (Supplementary Fig. S3).
Detection of Diarrheal Stool Samples by Previous One-step mPCR and Electrophoresis
By using the previous one-step mPCR and electrophoresis listed in the current commercial kit, 18 diarrheal stool samples were found to contain DEC strains among a total of 300 samples. The positive rate was 6%. Part of results are shown in Fig. 5, indicating that EHEC was identified positively in one sample; EIEC was identified positively in two samples; typical EPEC was identified positively in one sample; atypical EPEC was identified positively in five samples; ETEC was identified positively in four samples; and EAEC was identified positively in five samples.
Figure 5
Electrophoretogram of one-step mPCR for diarrheal stool samples. YP11 includes uidA, stx1, stx2 and escV, being identified as EHEC; YP55 and YP60 include uidA and invE, identified as EIEC; YP74, YP90, YP108, YP166 and YP299 include uidA and escV, identified as atypical EPEC;YP179 includes uidA, escV and bfpB, identified as typical EPEC; YP186 and YP191 include uidA, lt and stp, identified as ETEC; YP192 includes uidA, lt and sth, identified as ETEC; YP222 includes uidA and sth, identified as ETEC; YP223,YP248 and YP295 include uidA, but no virulence genes; YP255 and YP293 include uidA and pic, identified as EAEC; and YP276, YP277 and YP280 include uidA, pic and aggR, identified as EAEC.
Electrophoretogram of one-step mPCR for diarrheal stool samples. YP11 includes uidA, stx1, stx2 and escV, being identified as EHEC; YP55 and YP60 include uidA and invE, identified as EIEC; YP74, YP90, YP108, YP166 and YP299 include uidA and escV, identified as atypical EPEC;YP179 includes uidA, escV and bfpB, identified as typical EPEC; YP186 and YP191 include uidA, lt and stp, identified as ETEC; YP192 includes uidA, lt and sth, identified as ETEC; YP222 includes uidA and sth, identified as ETEC; YP223,YP248 and YP295 include uidA, but no virulence genes; YP255 and YP293 include uidA and pic, identified as EAEC; and YP276, YP277 and YP280 include uidA, pic and aggR, identified as EAEC.
Detection of Diarrheal Stool Samples by the Novel One-step mPCR + RDBH
These 300 diarrheal stool samples were also identified by the novel one-step mPCR + RDBH method on the AMTC instrument, where, 21 samples were detected to contain DEC strains. The positive rate was 7%. As shown in Fig. 6, EHEC was identified positively in one sample; EIEC was identified positively in two samples; typical EPEC was identified positively in one sample; atypical EPEC was identified positively in four samples; ETEC was identified positively in six samples; EAEC was identified positively in six samples; and ETEC+ atypical EPEC were identified simultaneously in one sample. Compared with current commercial kit, the relevance ratio of DEC detected by the AMTC method was increased by 1% in stool samples.
Figure 6
Qualitative detection of DEC strains in diarrheal stool samples by RDBH on AMTC instrument.YP11 includes uidA, stx1, stx2 and escV, being identified as EHEC; YP55 and YP60 include uidA, ipaH and invE, identified as EIEC; YP74 and YP90 include uidA and escV, identified as atypical EPEC; YP108 and YP166 include uidA, astA and escV, identified as atypical EPEC;YP179 includes uidA, escV and bfpB, identified as typical EPEC; YP186 includes uidA, lt and stp, identified as ETEC; YP191 includes uidA, astA, lt and stp, identified as ETEC; YP192 includes uidA, lt, astA and sth, identified as ETEC;YP222 includes uidA, astA and sth, identified as ETEC;YP223 includes uidA and estB, identified as ETEC; YP248 includes uidA, astA and estB, identified as ETEC; YP255 and YP293 include uidA, astA and pic, identified as EAEC; YP276, YP277 and YP280 include uidA, pic, aggR and astA, identified as EAEC; YP295 includes uidA and astA, but no virulence genes; and YP299 includes uidA, estB and escV, identified as atypical EPEC and ETEC.
Qualitative detection of DEC strains in diarrheal stool samples by RDBH on AMTC instrument.YP11 includes uidA, stx1, stx2 and escV, being identified as EHEC; YP55 and YP60 include uidA, ipaH and invE, identified as EIEC; YP74 and YP90 include uidA and escV, identified as atypical EPEC; YP108 and YP166 include uidA, astA and escV, identified as atypical EPEC;YP179 includes uidA, escV and bfpB, identified as typical EPEC; YP186 includes uidA, lt and stp, identified as ETEC; YP191 includes uidA, astA, lt and stp, identified as ETEC; YP192 includes uidA, lt, astA and sth, identified as ETEC;YP222 includes uidA, astA and sth, identified as ETEC;YP223 includes uidA and estB, identified as ETEC; YP248 includes uidA, astA and estB, identified as ETEC; YP255 and YP293 include uidA, astA and pic, identified as EAEC; YP276, YP277 and YP280 include uidA, pic, aggR and astA, identified as EAEC; YP295 includes uidA and astA, but no virulence genes; and YP299 includes uidA, estB and escV, identified as atypical EPEC and ETEC.
Discussion
With more detection indexes and improved detection rate of DEC, the AMTC method is able to detect 14 indexes in a single reaction. This would avoid the probability of undetected ipaH and estB. Compared with monoplex PCR, the AMTC method identified BP06 as ETEC, just owing to estB. Compared with commercial kit, the AMTC method identified BP02 as EIEC, and BP06 as ETEC, just owing to ipaH and estB. For the detection of diarrheal stool samples, compared with commercial kit, the AMTC method identified YP223, and YP248 as ETEC, just owing to estB; identified YP295 as EAEC, just owing to astA; and identified YP299 as ETEC+ atypical EPEC, just owing to estB.The AMTC method could be used to distinguish sub-type of DEC. Some researchers reported that astA encoded the EAST1, but astA is widely distributed in DEC, and its role in the pathogenicity of this organism remains unclear[13]. Some researchers reported that a strain harboring astA was associated with a waterborne outbreak of diarrhea in Japan[14]. So, further studies are needed to evaluate the significance of EAST1 as a virulence factor of DEC. This study showed 15 clinical strains contained astA, while 7 of them contained 3 sth, 1 stp and 3 escV. Obviously, astA is common among EHEC, EPEC, ETEC and EAEC, and each sample should be tested separately with specific primers such as stx1, stx2, escV, estB, lt, pic, aggR, astA, bfpB, sth and stp by monoplex PCR method. However, these processes could be completed using the newly-developed AMTC method in a single reaction. Some researchers believed that EAEC possesses both pic and aggR present in the virulence plasmid pAA[15,16]. Some researchers identified a few pic-positive and aggR-negative strains, and vice versa[17]. Reportedly, some researchers used only aggR for detecting pAA[10]. However, we found a positive single virulence gene and coexistence of two positive genes in the detection of diarrhea samples about EAEC.The AMTC method possesses high efficiency and high throughput. For example, EscV is common between EHEC and EPEC, and in order to distinguish these two pathogens, bfpB and stx1 + stx2 must also be run by monoplex PCR method. Meanwhile, when bfpB and stx1 + stx2 are negative, the results can be identified as atypical EPEC, with positive bfpB being identified as typical EPEC, and positive stx1 + stx2 identified as EHEC. The results obtained by us show this method is able to perform both simultaneous amplification of virulence genes from E. coli isolates and simultaneous differentiation of the 5 categories of DEC.The AMTC method has the advantages of good repeatability and stability. Two new indexes, ipaH and estB basing on monoplex PCR, and a multiplex PCR diagnostic kit, have been added to this method. Compared with the previous one-step mPCR, segment length of the PCR products for the novel one-step mPCR was basically the same, thus it could reduce competition between primers. Compared with electrophoretic detection, the fragments of poor amplification could also be detected with such RDBH method, resulting in a stable detection. Furthermore, one-step mPCR integrating with RDBH allows it to improve repeatability and stability of the detection results. Accordingly, the AMTC method would be a valuable contribution to the routine diagnostic laboratory tests while providing important information for the epidemiological and other studies.
Materials and Methods
Bacterial Strains
A total of eleven DEC strains used in this study were purchased from China Center of Industrial Culture Collection (CICC). They were Escherichia coli EHEC O 157:H7 (CICC 21530) containing Shiga-like toxin I (stx1), Shiga-like toxin II (stx2), eae and escV[18], Escherichia coli EPEC (CICC 10664) containing eae and escV, where EPEC can be classified as typical or atypical one based on the production of bundle-forming pili (bfp) encoded by the Escherichia adherence factor (EAF) gene[15], Escherichia coli EIEC (CICC 10662) containing ipaH and invE[19-22], Escherichia coli ETEC O78:K80 (CICC 10421) and O126: K71 (CICC 10415) containing the heat-labile toxin (LT) and the heat-stable toxin (ST)[22-25], Escherichia coli EAEC purchased from Deutsche Sammlung von Mikroorganismen und Zellkulturen (DSMZ), and it (DSMZ 10974) containing aggR, pic and enteroaggregative heat-stable enterotoxin EAST1 (astA)[26-28]. Some other diarrhea strains different from E. coli in this study were Salmonella enterica subsp. Enterica serovar Choleraesuis (CICC 21493), Shigella flexneri (CICC 21534), Shigella sonnei (CICC 21535), Vibrio parahaemolyticus CICC 21617), Campylobacter jejuni (CICC 22936) and Vibriocholera (CICC 23794).
Stool samples
A total of 300 diarrheal stool samples were collected from National Institute for Communicable Disease Control and Prevention, Chinese Center for Disease Control and Prevention. The samples were stored at −80 °C.
Preparation of DNA Templates
All DNA samples used in this study were extracted by QIAamp DNA Mini Kit (QIAGEN, Germany). The templates used for PCR comprise the DNA of EHEC O157:H7, EPEC, EIEC, ETEC O78:K80, ETEC O126: K71, EAEC, some other DEC strains, some diarrhea strains differing from E. coli, and diarrheal stool samples. The final concentration of DNA in extracts from bacterial strains and stool samples was 25 ng/µL.
Probes and Primers used for Detection of DEC
The oligonucleotide probes used in the AMTC corresponding to the reverse primers in one-step mPCR of a newly developed kit are listed in Table 1. An aminolinker C6 was added as a 5′-modified group to provide spaces between probes and immobilization substrates. The oligonucleotide primers used in monoplex PCR were collected from the China National Standard GB 4789.6–2016, being listed in Table 2. The final concentration of each primer used in the PCR amplification system depends on the GB 4789.6–2016. The primers used in a multiplex PCR diagnostic kit (a commercial kit currently used) were the components in the kit. The oligonucleotide primers used in a newly developed kit were designed by Primer premier v5.0, as shown in Table 3. The 5′ ends of the reverse primers were modified by a biotin group. Among them, the proportion of forward and reverse primers for each pair primers was 2:3. The final concentration of each primer in mixed PCR primers should be 10 µM. The predicted length of PCR products was ranged between 100 and 300 bp. All the primers and probes were synthesized by Sangon Biotech (Shanghai) Co., Ltd.
Table 1
Probes Used by RDBH on AMTC Instrument.
Gene
Probes Sequencea
uidA
P: 5′-NH2-CCGGGAATGGTGATTACCGACGAAA
stx1
P: 5′-NH2-TGTTACCTTTCCAGGTACA
stx2
P: 5′-NH2-CTGAAACTGCTCCTGTGT
escV
P: 5′-NH2-TGGCGATTATTCCTGGCTTTCCTAC
ipaH
P: 5′-NH2-CGCCTTTCCGATACCGTCTCTGCA
invE
P: 5′-NH2-CAGCAAAAGAGCATAGCATCCGAGA
estB
P: 5′-NH2-CAACAGTGACAACGGAGGCGA
lt
P: 5′-NH2-GATGATACTTGTAATGAGGAGA
pic
P: 5′-NH2-TTCTGCAGACGGTGGTTACA
aggR
P: 5′-NH2-GGAATATCAAAAGTAGATGC
astA
P: 5′-NH2- AACAGCCTGCGCTTCGTGTCATGG
bfpB
P: 5′-NH2-TCAGTTCGGACAGCAATAGC
sth
P: 5′-NH2-CTAAACCAGCAGGGTCTTCAA
stp
P: 5′-NH2-AATCAGAAAATATGAACGACAC
Positive-probe
5′-NH2-GCATCCAGATCAGAAGCAATAATGA
Negative-Probe
5′-NH2-CCCTCGGGTTAATGCGCGATTGTCAC
a5′- Modified group: Amino linker C6.
Table 2
Primers Used in Monoplex PCR.
Gene
Primer Sequencea
Amplicon Size (bp)
uidA
F: ATGCCAGTCCAGCGTTTTTGC
1487
R: AAAGTGTGGGTCAATAATCAGGAAGTG
stx1
F: CGATGTTACGGTTTGTTACTGTGACAGC
244
R: AATGCCACGCTTCCCAGAATTG
stx2
F: GTTTTGACCATCTTCGTCTGATTATTGAG
324
R: AGCGTAAGGCTTCTGCTGTGAC
escV
F: ATTCTGGCTCTCTTCTTCTTTATGGCT
544
R: CGTCCCCTTTTACAAACTTCATCGC
ipaH
F: TTGACCGCCTTTCCGATACC
647
R: ATCCGCATCACCGCTCAGAC
invE
F: CGATAGATGGCGAGAAATTATATCCCG
766
R: CGATCAAGAATCCCTAACAGAAGAATCAC
lt
F: GAACAGGAGGTTTCTGCGTTAGGTG
655
R: CTTTCAATGGCTTTTTTTTGGGAGTC
pic
F: AGCCGTTTCCGCAGAAGCC
1111
R: AAATGTCAGTGAACCGACGATTGG
aggR
F: ACGCAGAGTTGCCTGATAAAG
400
R: AATACAGAATCGTCAGCATCAGC
astA
F: TGCCATCAACACAGTATATCCG
102
R: ACGGCTTTGTAGTCCTTCCAT
bfpB
F: GACACCTCATTGCTGAAGTCG
910
R: CCAGAACACCTCCGTTATGC
sth
F: TGTCTTTTTCACCTTTCGCTC
171
R: CGGTACAAGCAGGATTACAACAC
stp
F: CCTCTTTTAGYCAGACARCTGAATCASTTG
157
R: CAGGCAGGATTACAACAAAGTTCACAG
aPrimer sequences were collected from the Chinese National Standard GB4789.6–2016.
Table 3
Primers Used in Multiplex PCR.
Gene
Primer Sequencea
Amplicon Size (bp)
uidA
F: GTCACGCCGTATGTTATTGCC
189
R: 5′biotin-CGGCGTGGTGTAGAGCATT
stx1
F: AAGAGCGATGTTACGGTTTGT
172
R: 5′biotin- GTCAGGCAGGACACTACTCAA
stx2
F: GTTCAGTGGTAATACAATGACCAG
204
R: 5′biotin- TACTCCGGAAGCACATTGCTGA
escV
F: GATGCTTTAGTTGCCCAGAT
220
R: 5′biotin- CCGCCAGAAACAAGAAGACC
ipaHb
F: TTCCTTGACCGCCTTTCC
131
R: 5′biotin- TCAGCAGCAACAGCGAAA
invEb
F: GCAGGAGCAGATCTTGAAG
208
R: 5′biotin- GAAAGGCACGAGTGACTTTC
estB
F: CACAACAGTGACAACGGAGGC
145
R: 5′biotin- CCGGCAAAGCTATTGGAAAA
lt
F: TCCCACCGGATCACCAAG
124
R: 5′biotin- GTGCTCAGATTCTGGGTCTCC
pic
F: CAAACGTATGGGTGACCTGC
191
R: 5′biotin- TGCTGTCGGTATAGGTCATCG
aggR
F: CGCCTAAAGGATGCCCTGAT
107
R: 5′biotin- ACAGAATCGTCAGCATCAGCTA
astA
F: TGCCATCAACACAGTATATCCG
102
R: 5′biotin- ACGGCTTTGTAGTCCTTCCAT
bfpB
F: TTCAAACGAGGAAACTAAACGC
158
R: 5′biotin- AATCGAATTTCAACTCTGCTCC
sth
F: TTCACCTTTCCCTCAGGATG
172
R: 5′biotin- ATAGCACCCGGTACAAGCAG
stp
F: ACTGAATCACTTGACTCTTCA
144
R: 5′biotin- AGCACAGGCAGGATTACAAC
Positive-olig
5′biotin-CTGGTACTTTGGACACTCGTTCTTC
/
aReverse primers were 5′-modified by biotin.
bThe ipaH and invE genes were targeted for detection of both Shigella and EIEC.
Probes Used by RDBH on AMTC Instrument.a5′- Modified group: Amino linker C6.Primers Used in Monoplex PCR.aPrimer sequences were collected from the Chinese National Standard GB4789.6–2016.Primers Used in Multiplex PCR.aReverse primers were 5′-modified by biotin.bThe ipaH and invE genes were targeted for detection of both Shigella and EIEC.
Monoplex PCR
PCR amplifications were performed as follows: 2 µL of bacterial extract was added to the reaction mixture with a final volume of 20 µL containing 10 µL Premix Taq™ (Takara, Code No. RR902A), 1 µL PCR primer mix and 7 µL ddH2O.These mixtures were pre-denatured at 94 °C for 5 min and then amplified for 30 cycles by using a thermal cycler (Model: BIORAD T100). Each cycle was composed of denaturation at 94 °C for 30 s, annealing at 63 °C for 30 s, and extension at 72 °C for 1.5 min. A final extension step was performed at 72 °C for 5 min, and the tubes were rapidly cooled to 4 °C. Qualitative detection of DEC was accomplished by the 2% agarose gel electrophoresis.
One-step mPCR
One-step mPCR was performed by using a multiplex PCR diagnostic kit and a newly developed kit, respectively. PCR mix of the multiplex PCR diagnostic kit, with a final volume of 25 µL, included 2 × PCR Buffer 12.5 µL, 10 × Multiplex Assay 2.5 µL, 25 × PCR Enzyme 1 µL, 2 µL of bacterial extract, and 7 µL of ddH2O. These mixtures were pre-denatured at 95 °C for 4 min and then amplified for 30 cycles by using a thermal cycler (Model: BIORAD T100). Each cycle was composed of denaturation at 95 °C for 30 s, annealing at 62 °C for 30 s, and extension at 72 °C for 90 s. A final extension step was conducted at 72 °C for 5 min, and the tubes were rapidly cooled to 4 °C. Qualitative detection of DEC was accomplished by the 2% agarose gel electrophoresis about a multiplex PCR diagnostic kit. PCR mix of the newly developed kit, with a final volume of 20 µL, included 10 µL of 2 × KAPA2G Fast Multiplex Mix (KAPA Biosystems, USA), 1 µL of mixed PCR primers, 2 µL of bacterial extract, and 7 µL of ddH2O. These mixtures were preheated at 37 °C for 5 min, pre-denatured at 95 °C for 3 min and then amplified for 35 cycles by using a thermal cycler (Model: BIORAD T100). Each cycle was composed of denaturation at 95 °C for 15 s, annealing at 55 °C for 30 s, and extension at 68 °C for 15 s. A final extension step was conducted at 68 °C for 3 min, and the tubes were rapidly cooled to 4 °C. Qualitative detection of DEC was accomplished by RDBH about a newly developed kit.
Microfluidic thin-film chip
DNA probes were spotted and immobilized on a nylon thin-film according to the surface design. This step can be performed manually or by a machine. Then, the nylon thin-film probes spot array was incubated in 80 °C for 1 h, and it was placed in a small cell with two small holes. The microfluidic thin-film chip consisted of three main parts: a square nylon thin-film, a small cell with two small holes, and two microfluidic tubes. The small cell was a small square plastic box with a sealing ring on the inner side of the lid. When a square nylon thin-film was placed into the small box, the lid was closed, forming a closed cell. PCR products were added to the reaction cell through the microfluidic tube. When the PCR products passed over the surface of the square nylon thin-film containing the probe array, the target DNA in the PCR products was captured by the sensing surface DNA base pairing between the probes and target DNA[12].
Qualitative Detection of DEC with RDBH
The AMTC instrument consisted of four main parts: a machine shell, micro-reaction cell, sample needle with pump, and sample and waste liquid plate. The eight microfluidic thin-film chip cells were placed on the micro-reaction cell of the AMTC device (Sichuan Hua Hansan Bio Technology Co., Ltd. #39, Fucheng West Rd., Chengdu, 610041, China). PCR products were added as samples to the sample plate of the AMTC device, and then the single-stranded DNA (Positive-Oligo, 10 μmol/L) complementary to the positive control (PC) probe was added to each PCR product sample for quality control. The hybridization buffer, cleaning buffers, enzyme buffer, and dyeing agent (NBT and BCIP) were placed in sample plate, with the signal being visualized with streptavidin-alkaline phosphatase color development kit (ZSGB-BIO, China). The sample needle with pump operated with an up and down movement and took different samples by rotating the sample plate. Under the control of an automatic hybridization program, the AMTC instrument could add samples and perform the reaction, washing, and coloring steps. The running procedures and time of the AMTC instrument were listed in Table 4.
Table 4
The running procedures of the AMTC instrument.
Procedure
Reagent
Temperature (°C)
Time (min)
deactivation
deactivation solution
37
8
deactivation cleaning
deactivation cleaning solution
60
5
hybridization
hybridization solution
45
45
hybridization cleaning
hybridization cleaning solution
52
5
hybridization cleaning
hybridization cleaning solution
52
5
enzyme labelling
enzyme solution
42
30
enzyme cleaning 1
enzyme cleaning solution 1
42
5
enzyme cleaning 2
enzyme cleaning solution 2
37
5
enzyme cleaning 2
enzyme cleaning solution 2
37
5
color rendering
Color-substrate solution
37
10
chromogenic cleaning
distilled water
/
2
chromogenic cleaning
distilled water
/
2
chromogenic cleaning
distilled water
/
2
Interpretation of results
/
/
/
The running procedures of the AMTC instrument.
Statistical analysis
The criterion for classification of diarrhoea E. coli was shown in Table 5. According to the criterion for classification, positive samples were identified. Compared with the total number of samples, the positive rate of different methods can be calculated.
Table 5
The criterion for classification of diarrhoea E. coli.
Authors: Joseph Erume; Prageeth Wijemanne; Emil M Berberov; Stephen D Kachman; Daniel J Oestmann; David H Francis; Rodney A Moxley Journal: Vet Microbiol Date: 2012-08-03 Impact factor: 3.293
Authors: S J Savarino; A Fasano; J Watson; B M Martin; M M Levine; S Guandalini; P Guerry Journal: Proc Natl Acad Sci U S A Date: 1993-04-01 Impact factor: 11.205
Authors: Marwa I Abdel-Hamid; Mahmoud M Bendary; Mahmoud A Elfaky; Eman Khalifa; Walaa A Alshareef; Rasha A Mosbah; Sara T Elazab; Mohammed M Ghoneim; Mohammad M Al-Sanea Journal: Appl Microbiol Biotechnol Date: 2022-02-08 Impact factor: 4.813
Authors: Mahmoud M Bendary; Marwa I Abdel-Hamid; Walaa A Alshareef; Hanan M Alshareef; Rasha A Mosbah; Nasreen N Omar; Mohammad M Al-Sanea; Majid Alhomrani; Abdulhakeem S Alamri; Walaa H Moustafa Journal: Antibiotics (Basel) Date: 2022-04-21
Authors: Mahmoud M Bendary; Marwa I Abd El-Hamid; Majid Alhomrani; Abdulhakeem S Alamri; Rana Elshimy; Rasha A Mosbah; Mosa M Bahnass; Nasreen N Omar; Mohammad M Al-Sanea; Arwa R Elmanakhly; Nesreen A Safwat; Walaa A Alshareef Journal: Biology (Basel) Date: 2022-07-02