Literature DB >> 30134259

Virtual Fitting and Hemodynamic Simulation of the EVAHEART 2 Left Ventricular Assist Device and Double-Cuff Tipless Inflow Cannula.

Simon Johannes Sonntag1, Erin Lipinski2, Michael Neidlin1, Kristin Hugenroth1,3, Robert Benkowski4, Tadashi Motomura2, Tim Arne Simon Kaufmann1,3.   

Abstract

Inflow malposition during surgery, postoperative pump migration, inflow obstruction, and right ventricular compression are major contributors to low flow and adverse events in patients with ventricular assist devices (VADs). These position abnormalities can lead to adverse events including ischemic stroke. To address these problems, we conducted a virtual anatomical fitting study and hemodynamic simulation on iterative cannula designs, resulting in the EVAHEART 2 with the novel double-cuff tipless (DCT) inflow cannula and smaller pump design. Anatomical fitting was based on computed tomography scans of six patients with heart failure, and a fluid-structure-integration (FSI) model of the left ventricle with a lumped parameter model of the entire cardiovascular system during VAD support was created. Using this model, the hemodynamics of three inflow cannula insertion lengths for two patient-specific ventricles were calculated for both full and partial VAD support. The DCT cannula with the smaller pump housing proved resistant to obstruction even when the pump housing was adjusted. The complete system also had a smaller pump pocket size than the other designs and avoided position abnormalities that commonly lead to adverse events. Compared with conventional cadaver studies, virtual fitting and numerical simulations are more beneficial and economical for iteratively designing medical devices.

Entities:  

Mesh:

Year:  2019        PMID: 30134259     DOI: 10.1097/MAT.0000000000000867

Source DB:  PubMed          Journal:  ASAIO J        ISSN: 1058-2916            Impact factor:   2.872


  3 in total

1.  LVAD decommissioning for myocardial recovery: Long-term ventricular remodeling and adverse events.

Authors:  Eleanor F Gerhard; Lu Wang; Ramesh Singh; Stephan Schueler; Leonard D Genovese; Andrew Woods; Daniel Tang; Nicola Robinson Smith; Mitchell A Psotka; Sian Tovey; Shashank S Desai; Djordje G Jakovljevic; Guy A MacGowan; Palak Shah
Journal:  J Heart Lung Transplant       Date:  2021-08-11       Impact factor: 10.247

2.  The influence of left ventricular assist device inflow cannula position on thrombosis risk.

Authors:  Mojgan Ghodrati; Alexander Maurer; Thomas Schlöglhofer; Thananya Khienwad; Daniel Zimpfer; Dietrich Beitzke; Francesco Zonta; Francesco Moscato; Heinrich Schima; Philipp Aigner
Journal:  Artif Organs       Date:  2020-05-06       Impact factor: 3.094

3.  Effects of the atrium on intraventricular flow patterns during mechanical circulatory support.

Authors:  Mojgan Ghodrati; Thomas Schlöglhofer; Alexander Maurer; Thananya Khienwad; Daniel Zimpfer; Dietrich Beitzke; Francesco Zonta; Francesco Moscato; Heinrich Schima; Philipp Aigner
Journal:  Int J Artif Organs       Date:  2021-10-29       Impact factor: 1.595

  3 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.