Literature DB >> 30117485

Role of EUS-guided liver biopsy in benign parenchymal disease (with video).

Jason Y Huang1.   

Abstract

Entities:  

Year:  2018        PMID: 30117485      PMCID: PMC6106156          DOI: 10.4103/eus.eus_33_18

Source DB:  PubMed          Journal:  Endosc Ultrasound        ISSN: 2226-7190            Impact factor:   5.628


× No keyword cloud information.

INTRODUCTION

Etiology of liver disease is often established on serology, metabolic profile, or less commonly genetic testing in conjunction with sound structural imaging. Staging of liver disease, however, is more complex and noninvasive methods such as transient elastography, shear wave elastography, or specialized magnetic resonance imaging can be helpful in this regard. However, the ultimate gold standard is a liver biopsy (LB) for both diagnosis (especially in seronegative disease) and staging of both acute and chronic liver disease. This can be performed via the percutaneous, transjugular, or surgical approach. EUS-guided LB (EUS-LB) is a promising new technique with some advantages over the traditional methods. This chapter will cover the merits of EUS-LB including technique, needle types, safety, and diagnostic yield.

EUS TECHNIQUE

The patient is positioned in the typical left lateral position under moderate sedation. A linear echoendoscope is used to study the liver parenchyma with Doppler imaging. Avoidance of ductal structures is of paramount importance, and a 19G needle is used to procure liver cores via a transgastric and/or transduodenal approach to target the left or right lobe of liver [Figure 1a]. The optimal technique is yet to be established hence techniques vary among expert centers. This could range from a single pass to multiple passes, a variable number of to-and-fro needle movements and degree of suction is at the discretion of the proceduralist. Tissue acquisition technique has been evaluated recently in cadaveric tissue[1] found no difference between the degree of suction ranging from slow pull (capillary pressure) to 30 ml syringe suction. In general, however, higher suction (20 ml) with larger needles tend to generate greater negative pressures at the needle tip.[2] Priming the needle with a column of fluid may increase the volume of tissue acquisition[3] as demonstrated in a three-dimensional computational fluid dynamic model. Finally, cessation of Doppler signals [Figure 1b] within the needle tracts should be observed before needle withdrawal from the Glisson's capsule to theoretically reduce the risk of subcapsular hematoma. Our current technique includes high suction (20 ml) with a 19G needle primed with heparin-saline to decrease clotting of blood within the needle lumen.
Figure 1

(a) FNA into the left lobe of liver, care is taken to avoid all ductal structures. (b) Doppler signal within the needle tract therefore the needle is yet to be withdrawn from the liver parenchyma

(a) FNA into the left lobe of liver, care is taken to avoid all ductal structures. (b) Doppler signal within the needle tract therefore the needle is yet to be withdrawn from the liver parenchyma

NEEDLE TYPES

Four-needle types have been used for EUS-LB in the clinical setting. The tru-cut biopsy (TCB) needle [Figure 2a] was first used for EUS-LB in 2007[4] on two patients demonstrating feasibility. Two further studies were then conducted by Gleeson and Levy[5] and Dewitt et al.[6] yielding somewhat suboptimal specimens but without adverse events. Subsequently, three studies used the straight standard needles [SSN, Figure 2b][789] with better results [Table 1]. A study utilizing the core histology needle [CHN, Figure 2c] with a built-in reverse bevel followed and a comparison between TCB and CHN revealed the CHN to be superior to the TCB needle.[11] The only study to involve SSN and CHN[12] showed the SSN procured almost double the number of CPT compared to the CHN (19.4 vs. 9.8). Most recently, a new shark core needle [SC, Figure 2d] had been shown in a cadaveric study[13] to be superior to all preceding needle types; even better than the 18G percutaneous LB needles.[1] Clinical studies were subsequently carried out on 165 patients with excellent yield [Table 1]; although, this was not a comparative study.[10]
Figure 2

(a) True-cut biopsy needle. (b) Standard straight needle. (c) Core histology needle with reverse bevel. (d) Shark core

Table 1

Summary of results in the literature

(a) True-cut biopsy needle. (b) Standard straight needle. (c) Core histology needle with reverse bevel. (d) Shark core Summary of results in the literature

SPECIMEN HANDLING

Following withdrawn of the FNA needle from the linear echoendoscope, the liver cores are expressed from the FNA needle. This is the best accomplished by gentle, steady flushing of saline from the needle handle. If, however, the specimen does not deliver with saline flush, the stylet can be used to advance the specimen, followed again by saline flush. At this point, it is ideal to separate the liver cores from the blood clots carefully as these cores are extremely fragile. Blood should be removed as this is likely to hinder histological preparation and assessment. The cores can either be placed directly into a formalin bottle or placed on filter paper then enclosed by a cassette and submitted in formalin [Video 1].

TECHNICAL ADVANTAGE AND SUCCESS RATE

The key advantage of EUS-LB is in obese patients with liver disease (e.g., suspected nonalcoholic steatohepatitis-NASH). This patient cohort may pose technical difficulties to the percutaneous or transjugular methodologies due to subcutaneous adiposity. There will also be an increasing need for LB in patients with NASH because these patients are at risk of progression to advanced fibrosis.[141516] EUS-LB in a morbidly obese patient would not pose any additional technical challenges to the endoscopist, as internally, there is little anatomical variability with views obtained at EUS regardless of body weight. TLB actually carries a 3.2% chance of procedural failure largely due to venous cannulation difficulties.[17] There had been no reports of technical failures related to EUS-LB to date.

PATIENT SAFETY AND SATISFACTION

The conventional algorithm for higher risk patients (obese, coagulopathic, and thrombocytopenic) are often deferred for TLB which carries a complication rate of up to 7.5%;[171819] however, major complication rate between 0.5% and 1.8%,[171819] which is very similar to image-guided PLB.[20] The collective patients who had undergone EUS-LB are 470 [Table 1], with only two reports of major complication (both involved bleeding managed conservatively). This early data would suggest EUS-LB is relatively safe; however, certainly larger studies are necessary. Patients who have had both the percutaneous and EUS-LB preferred the EUS-LB[7] and were happy to have it again if necessary. Reports of EUS-LB-related pain are rare;[78911] therefore, the recovery protocol is no different to that of a diagnostic endoscopy which translates into improved flow efficiency compared to PLB patients who would have to lie on their right side for a several hours to reduce risk of bleeding (and pain) as studies have shown 20% of PLB patients experience severe pain post-PLB,[21]35% requiring analgesia[22] and 39% had ongoing pain at 24 h post-PLB.[23]

DIAGNOSTIC YIELD AND STAGING OF CHRONIC LIVER DISEASE

The EUS-LB technique is capable of a high diagnostic yield [Table 1]. The diagnostic yield is between 90% and 100%. Objective assessment of histologic yield revealed that studies using non (TCB) needles have produced a mean CPT yield of at least 9 CPTs from 2 to 3 passes (median) which is more than adequate by conventional standards.[24] Although the staging of viral hepatitis may require a higher quality specimen,[25] the need for liver biopsies in the management of viral hepatitis has declined significantly.[23] EUS-LB would be particularly well suited for diseases with patchy distribution[26] (e.g., Fatty liver disease) as multiple to and fro movements can sample liver parenchyma more widely as well as sampling both left and right lobes if required. There has been no significant difference in yield (CPTs) when targeting left or right lobe of the liver via the traditional percutaneous[27] or the new EUS[9] method. EUS-LB is capable of obtaining very impressive length of specimen; however, there is a tendency toward excessive fragmentation which may hinder histological interpretation [Figure 3a]. Hence, emphasis on total length of specimen probably is of less importance as opposed to length of the longest intact core [Figure 3b].
Figure 3

(a) Severe fragmentation of liver cores (purple) in a background of blood clots (red). (b) Intact cores with minimal fragmentation

(a) Severe fragmentation of liver cores (purple) in a background of blood clots (red). (b) Intact cores with minimal fragmentation The endoscopic approach facilitates concurrent assessment for the presence or complications of portal hypertension by conventional and novel means. A conventional endoscopic mucosal assessment for evidence of portal hypertension can be carried out (e.g. gastroscopy to look for varices and portal hypertensive gastropathy) before EUS-LB and the novel method of measuring portal pressure gradient can be performed simultaneously.[28] These two additional examinations can certainly be invaluable adjuncts to the liver histology in the staging of chronic liver disease.

SUMMARY

The inherent advantages of the endosonographic approach to LB are clear. From the patient's perspective, it appears safe and largely painless. From a technical standpoint, it allows for sampling of a wider area of the liver and is not hindered by morbid obesity, therefore, highly successful in these patients. Finally, diagnostic yield is now well beyond conventional standards and further bolstered by information gathered from same session mucosal inspection for signs of portal hypertension and direct measurement of the portal pressure gradient. With ongoing refinement in needle type and suction techniques, further improvements in sample quality are only a matter of time. For some, adoption of this technique may be simply a mental barrier, as conventionally, liver biopsies have come from larger 16 or 18G needles, which may no longer be necessary.

Conflict of Interest

There are no conflicts of interest.
  27 in total

1.  Pain experienced during percutaneous liver biopsy.

Authors:  L Castéra; I Nègre; K Samii; C Buffet
Journal:  Hepatology       Date:  1999-12       Impact factor: 17.425

2.  EUS-guided routine liver biopsy in selected patients.

Authors:  Abraham Mathew
Journal:  Am J Gastroenterol       Date:  2007-10       Impact factor: 10.864

3.  Histological adequacy of EUS-guided liver biopsy when using a 19-gauge non-Tru-Cut FNA needle.

Authors:  Niraj Gor; Suhail B Salem; Shriram Jakate; Rikin Patel; Nikunj Shah; Abhitabh Patil
Journal:  Gastrointest Endosc       Date:  2013-07-31       Impact factor: 9.427

4.  Optimizing EUS-guided liver biopsy sampling: comprehensive assessment of needle types and tissue acquisition techniques.

Authors:  Allison R Schulman; Christopher C Thompson; Robert Odze; Walter W Chan; Marvin Ryou
Journal:  Gastrointest Endosc       Date:  2016-08-13       Impact factor: 9.427

5.  High yield of same-session EUS-guided liver biopsy by 19-gauge FNA needle in patients undergoing EUS to exclude biliary obstruction.

Authors:  Stavros N Stavropoulos; Gene Y Im; Zahra Jlayer; Michael D Harris; Teodor C Pitea; George K Turi; Peter F Malet; David M Friedel; James H Grendell
Journal:  Gastrointest Endosc       Date:  2012-02       Impact factor: 9.427

6.  EUS-guided fine-needle core liver biopsy sampling using a novel 19-gauge needle with modified 1-pass, 1 actuation wet suction technique.

Authors:  Jose Nieto; Huda Khaleel; Youssef Challita; Melissa Jimenez; Todd H Baron; Laura Walters; Kelli Hathaway; Ketul Patel; Ali Lankarani; Michael Herman; David Holloman; Sammy Saab
Journal:  Gastrointest Endosc       Date:  2017-05-24       Impact factor: 9.427

7.  Initial experience with EUS-guided Tru-cut biopsy of benign liver disease.

Authors:  John Dewitt; Kathleen McGreevy; Oscar Cummings; Stuart Sherman; Julia K Leblanc; Lee McHenry; Mohammad Al-Haddad; Naga Chalasani
Journal:  Gastrointest Endosc       Date:  2009-03       Impact factor: 9.427

8.  EUS-guided portal pressure gradient measurement with a simple novel device: a human pilot study.

Authors:  Jason Y Huang; Jason B Samarasena; Takeshi Tsujino; John Lee; Ke-Qin Hu; Christine E McLaren; Wen-Pin Chen; Kenneth J Chang
Journal:  Gastrointest Endosc       Date:  2016-09-29       Impact factor: 9.427

9.  Impact of liver biopsy size on histological evaluation of chronic viral hepatitis: the smaller the sample, the milder the disease.

Authors:  Guido Colloredo; Maria Guido; Aurelio Sonzogni; Gioacchino Leandro
Journal:  J Hepatol       Date:  2003-08       Impact factor: 25.083

10.  Incidence and Risk Factors for Adverse Events Related to Image-Guided Liver Biopsy.

Authors:  James H Boyum; Thomas D Atwell; Grant D Schmit; John J Poterucha; Cathy D Schleck; W Scott Harmsen; Patrick S Kamath
Journal:  Mayo Clin Proc       Date:  2016-02-02       Impact factor: 7.616

View more
  1 in total

1.  Cytokines predict virological response in chronic hepatitis B patients receiving peginterferon alfa-2a therapy.

Authors:  Wen-Kang Fu; Jie Cao; Ning-Ning Mi; Chong-Fei Huang; Long Gao; Jin-Duo Zhang; Ping Yue; Bing Bai; Yan-Yan Lin; Wen-Bo Meng
Journal:  World J Clin Cases       Date:  2020-06-06       Impact factor: 1.337

  1 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.