Literature DB >> 30117200

Three-dimensional femoral head coverage in the standing position represents that measured in vivo during gait.

Keisuke Uemura1, Penny R Atkins1,2, Steve A Maas2,3,4, Christopher L Peters1,2, Andrew E Anderson1,2,3,5.   

Abstract

Individuals with over- or under-covered hips may develop hip osteoarthritis. Femoral head coverage is typically evaluated using radiographs, and/or computed tomography (CT) or magnetic resonance images obtained supine. Yet, these static assessments of coverage may not provide accurate information regarding the dynamic, three-dimensional (3-D) relationship between the femoral head and acetabulum. The objectives of this study were to: (1) quantify total and regional 3-D femoral head coverage in a standing position and during gait, and (2) quantify the relationship between 3-D femoral head coverage in standing to that measured during gait. The kinematic position of the hip during standing and gait was measured in vivo for 11 asymptomatic morphologically normal subjects using dual fluoroscopy and model-based tracking of 3-D CT models. Percent coverage in the standing position and during gait was measured overall and on a regional basis (anterior, superior, posterior, inferior). Coverage in standing was correlated with that measured during gait. For total coverage, very little change in coverage occurred during gait (range: 35.0-36.7%; mean: 36.2%). Coverage at each time point of gait strongly correlated with coverage during standing (r = 0.929-0.989). The regions thought to play an important role in weight bearing (i.e. anterior, superior, posterior) were significantly correlated with coverage in standing during the stance phase. Our results suggest that coverage measured in a standing position is a good surrogate for coverage measured during gait. Clin. Anat. 31:1177-1183, 2018.
© 2018 Wiley Periodicals, Inc. © 2018 Wiley Periodicals, Inc.

Entities:  

Keywords:  dual fluoroscopy; dynamic; femoral head coverage; femur; gait analysis; hip; morphometrics; pelvis

Mesh:

Year:  2018        PMID: 30117200      PMCID: PMC6599490          DOI: 10.1002/ca.23262

Source DB:  PubMed          Journal:  Clin Anat        ISSN: 0897-3806            Impact factor:   2.414


  7 in total

1.  The anterior center edge angle has limited ability to predict three-dimensional coverage of the femoral head in patients with developmental dysplasia of the hip undergoing curved periacetabular osteotomy.

Authors:  Keisuke Uemura; Toshihito Hiraiwa; Masashi Okamoto; Kunihiko Tokunaga; Andrew E Anderson
Journal:  Arch Orthop Trauma Surg       Date:  2022-01-03       Impact factor: 2.928

2.  Prediction of femoral head coverage from articulated statistical shape models of patients with developmental dysplasia of the hip.

Authors:  Penny R Atkins; Praful Agrawal; Joseph D Mozingo; Keisuke Uemura; Kunihiko Tokunaga; Christopher L Peters; Shireen Y Elhabian; Ross T Whitaker; Andrew E Anderson
Journal:  J Orthop Res       Date:  2021-12-05       Impact factor: 3.102

3.  Three-dimensional foot trajectory in female patients with end-stage hip osteoarthritis during walking.

Authors:  Yu Kiko; Taiki Ogata; Hirotaka Uchitomi; Masaaki Matsubara; Yoshihiro Miyake; Yoshiaki Wada
Journal:  Sci Rep       Date:  2022-06-14       Impact factor: 4.996

4.  Does Acetabular Coverage Vary Between the Supine and Standing Positions in Patients with Hip Dysplasia?

Authors:  Tetsuya Tachibana; Masanori Fujii; Kenji Kitamura; Tetsuro Nakamura; Yasuharu Nakashima
Journal:  Clin Orthop Relat Res       Date:  2019-11       Impact factor: 4.176

5.  Does Patient-specific Functional Pelvic Tilt Affect Joint Contact Pressure in Hip Dysplasia? A Finite-element Analysis Study.

Authors:  Kenji Kitamura; Masanori Fujii; Satoshi Ikemura; Satoshi Hamai; Goro Motomura; Yasuharu Nakashima
Journal:  Clin Orthop Relat Res       Date:  2021-08-01       Impact factor: 4.755

6.  In Vivo Quantification of Hip Arthrokinematics during Dynamic Weight-bearing Activities using Dual Fluoroscopy.

Authors:  Penny R Atkins; Niccolo M Fiorentino; Andrew E Anderson
Journal:  J Vis Exp       Date:  2021-07-02       Impact factor: 1.424

7.  The effect of pelvic tilt on three-dimensional coverage of the femoral head: A computational simulation study using patient-specific anatomy.

Authors:  Keisuke Uemura; Penny R Atkins; Christopher L Peters; Andrew E Anderson
Journal:  Anat Rec (Hoboken)       Date:  2019-12-04       Impact factor: 2.064

  7 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.