Literature DB >> 30107037

Assessment of artefacts produced by metal posts on CBCT images.

A P Lira de Farias Freitas1, Y W Cavalcanti2, F C M Costa1, L R Peixoto1, A M A Maia1, K Rovaris1, P M Bento1, D P Melo1.   

Abstract

AIM: To evaluate artefact intensity in cone beam computed tomography (CBCT) images of two alloys used in metal posts scanned using different exposure parameters.
METHODOLOGY: The sample consisted of 20 single-rooted teeth divided into two groups for use with either a NiCr post or AgPd post. All teeth were scanned with and without their corresponding metal posts and with and without the presence of an extra restored tooth in the arch. The samples were scanned using CS 9000 3D scanner with two exposure protocols: 85 kV 6.3 mA and 85 kV 10 mA. Voxel size and FOV were fixed at 0.100 mm and 5 cm × 3.75 cm. The presence of artefacts was assessed qualitatively by two calibrated observers using the CBCT volume and paired 2D images, and quantitatively by one trained observer, using ImageJ software. Wilcoxon's signed rank, Mann-Whitney, kappa and chi-square tests were used for qualitative analyses. Two-way anova and Tukey's tests were used for quantitative analyses. All analyses were conducted considering the 95% confidence level (α < 0.05).
RESULTS: For the CBCT volume qualitative analysis, significant differences were observed between the metal alloys in the presence of an extra restored tooth, with higher artefact intensity for AgPd when assessing hypodense halos and lines (P = 0.006). Images with two restored teeth had significantly more hypodense and hyperdense lines (P = 0.033). When evaluating exposure parameters and number of restored teeth, the paired image quality analysis revealed significant disagreement between observers for diagnostic image quality (P = 0.001). Quantitative artefact analysis revealed higher artefact intensity for the AgPd posts in the presence of two restored teeth.
CONCLUSION: Although the exposure parameters tested did not interfere with artefact intensity, post alloys with a higher atomic number and the presence of another metal structure in the arch increased artefact intensity and impaired the diagnostic quality of CBCT images.
© 2018 International Endodontic Journal. Published by John Wiley & Sons Ltd.

Entities:  

Keywords:  artefacts; cone beam computed tomography; imaging; three-dimensional

Mesh:

Substances:

Year:  2018        PMID: 30107037     DOI: 10.1111/iej.12999

Source DB:  PubMed          Journal:  Int Endod J        ISSN: 0143-2885            Impact factor:   5.264


  5 in total

1.  Mapping the expression of beam hardening artefacts produced by metal posts positioned in different regions of the dental arch.

Authors:  Rocharles C Fontenele; Amanda Farias Gomes; Lucas P Lopes Rosado; Frederico S Neves; Deborah Q Freitas
Journal:  Clin Oral Investig       Date:  2020-08-09       Impact factor: 3.573

2.  Influence of size of field of view (FOV), position within the FOV, and scanning mode on the detection of root fracture and observer's perception of artifacts in CBCT images.

Authors:  Martina Gerlane de Oliveira Pinto; Saulo L Sousa Melo; Fernanda Clotilde Mariz Suassuna; Luiz Eduardo Marinho; José Bruno da Silva Leite; Andre Ulisses Dantas Batista; Patrícia Meira Bento; Daniela Pita Melo
Journal:  Dentomaxillofac Radiol       Date:  2021-02-10       Impact factor: 3.525

Review 3.  Diagnosis of cracked teeth using cone-beam computed tomography: literature review and clinical experience.

Authors:  Antian Gao; Dantong Cao; Zitong Lin
Journal:  Dentomaxillofac Radiol       Date:  2021-04-29       Impact factor: 3.525

4.  Influence of tooth position within the field of view on the intensity of cone-beam computed tomographic imaging artifacts when assessing teeth restored with various intracanal materials.

Authors:  Martina Gerlane de Oliveira Pinto; Saulo Leonardo Sousa Melo; Yuri Wanderley Cavalcanti; Elisa Diniz de Lima; Patrícia Meira Bento; Daniela Pita de Melo
Journal:  Imaging Sci Dent       Date:  2020-06-18

5.  Magnitude of beam-hardening artifacts produced by gutta-percha and metal posts on cone-beam computed tomography with varying tube current.

Authors:  Hugo Gaêta-Araujo; Eduarda Helena Leandro Nascimento; Rocharles Cavalcante Fontenele; Arthur Xavier Maseti Mancini; Deborah Queiroz Freitas; Christiano Oliveira-Santos
Journal:  Imaging Sci Dent       Date:  2020-03-17
  5 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.