Literature DB >> 30105466

Use of Speckle Tracking Echocardiography to Assess Left Ventricular Systolic Function in Patients with Surgically Repaired Tetralogy of Fallot: Global and Segmental Assessment.

Bassel Mohammad Nijres1, John Bokowski2, Maytham Al-Kubaisi2, Ra-Id Abdulla2, Joshua J Murphy2, Sawsan Awad2, Karim A Diab2.   

Abstract

Patients with repaired Tetralogy of Fallot (rToF) can have significant right and left ventricular dysfunction which can impact clinical outcome. Conventional echocardiographic evaluation using ejection fraction can be limited in detecting early stages of deteriorating left ventricular (LV) systolic function. Speckle-tracking echocardiography (STE) provides a promising emerging tool for early detection of LV systolic dysfunction. The aim of this cross-sectional study is to evaluate the left ventricular global and regional function using STE in rToF patients with preserved left ventricular ejection fraction to detect early signs of LV dysfunction. The study is a retrospective review of the medical records and transthoracic echocardiograms of rTOF patients who were seen in the pediatric cardiology clinic at our institution from August 2016 till May 2018. The rTOF group was compared with a matched healthy control group. Offline strain analysis of TTE studies was completed in each subject according to mode set by the American Society of Echocardiography. Twenty-two patients with rTOF and 22 age-matched controls (rTOF 18.7 ± 6 years and control 14.6 ± 9.6 years, P value 0.19) were included during the study period. The rTOF group consisted of 12 males and 10 females, whereas the control group consisted of 15 males and 7 females. There was no significant difference in terms of LV ejection fraction using both 2-chamber as well as 4-chamber views. Global LV longitudinal strain was significantly lower in the rTOF group compared with the control group (rTOF - 15.92 ± 3.16 vs control - 22.79 ± 2.45, P value 0.00). All 17 segments showed significantly lower longitudinal strains in rTOF group compared with the control group. Global circumferential left ventricle strain was significantly lower in the rTOF patients compared with the control group (- 17.24 ± 5.86 vs - 22.74 ± 3.99, P value 0.001). 13 out of 16 segments had lower circumferential strains in the rTOF patients compared with controls. Asymptomatic surgically repaired TOF patients exhibited abnormal segmental and global left ventricle longitudinal and circumferential strains despite having normal left ventricle ejection fraction. Our findings suggest subclinical damage to the left ventricle systolic function post-surgical repair of TOF. 2-D speckle-tracking echocardiography may be used as a valuable method in the early recognition of left myocardial systolic function impairment in patients after TOF repair. The application of this method to guide clinical decision and management of rTOF patients such as earlier pulmonary valve replacement or risk stratification for sudden cardiac death needs further investigation.

Entities:  

Keywords:  Left ventricular systolic dysfunction; Speckle tracking echocardiography; Tetralology of Fallot

Mesh:

Year:  2018        PMID: 30105466     DOI: 10.1007/s00246-018-1950-4

Source DB:  PubMed          Journal:  Pediatr Cardiol        ISSN: 0172-0643            Impact factor:   1.655


  40 in total

1.  Factors associated with impaired clinical status in long-term survivors of tetralogy of Fallot repair evaluated by magnetic resonance imaging.

Authors:  Tal Geva; Bryan M Sandweiss; Kimberlee Gauvreau; James E Lock; Andrew J Powell
Journal:  J Am Coll Cardiol       Date:  2004-03-17       Impact factor: 24.094

Review 2.  NON-invasive imaging: Two dimensional speckle tracking echocardiography: basic principles.

Authors:  Hermann Blessberger; Thomas Binder
Journal:  Heart       Date:  2010-05       Impact factor: 5.994

3.  Assessment of myocardial deformation in children using Digital Imaging and Communications in Medicine (DICOM) data and vendor independent speckle tracking software.

Authors:  Laurens P Koopman; Cameron Slorach; Cedric Manlhiot; Brian W McCrindle; Edgar T Jaeggi; Luc Mertens; Mark K Friedberg
Journal:  J Am Soc Echocardiogr       Date:  2010-11-20       Impact factor: 5.251

4.  Ventricular size and function assessed by cardiac MRI predict major adverse clinical outcomes late after tetralogy of Fallot repair.

Authors:  A L Knauth; K Gauvreau; A J Powell; M J Landzberg; E P Walsh; J E Lock; P J del Nido; T Geva
Journal:  Heart       Date:  2006-11-29       Impact factor: 5.994

5.  Noninvasive myocardial strain measurement by speckle tracking echocardiography: validation against sonomicrometry and tagged magnetic resonance imaging.

Authors:  Brage H Amundsen; Thomas Helle-Valle; Thor Edvardsen; Hans Torp; Jonas Crosby; Erik Lyseggen; Asbjørn Støylen; Halfdan Ihlen; João A C Lima; Otto A Smiseth; Stig A Slørdahl
Journal:  J Am Coll Cardiol       Date:  2006-01-26       Impact factor: 24.094

6.  Pressure and volume loading of the right ventricle have opposite effects on left ventricular ejection fraction.

Authors:  E K Louie; S S Lin; S I Reynertson; B H Brundage; S Levitsky; S Rich
Journal:  Circulation       Date:  1995-08-15       Impact factor: 29.690

7.  Left ventricular contractile state after surgical correction of tetralogy of Fallot: risk factors for late left ventricular dysfunction.

Authors:  G Hausdorf; C Hinrichs; C A Nienaber; C Schark; E W Keck
Journal:  Pediatr Cardiol       Date:  1990-04       Impact factor: 1.655

8.  Comparison of two- and three-dimensional echocardiography with sequential magnetic resonance imaging for evaluating left ventricular volume and ejection fraction over time in patients with healed myocardial infarction.

Authors:  Carly Jenkins; Kristen Bricknell; Jonathan Chan; Lizelle Hanekom; Thomas H Marwick
Journal:  Am J Cardiol       Date:  2006-12-01       Impact factor: 2.778

9.  Life expectancy without surgery in tetralogy of Fallot.

Authors:  E G Bertranou; E H Blackstone; J B Hazelrig; M E Turner; J W Kirklin
Journal:  Am J Cardiol       Date:  1978-09       Impact factor: 2.778

10.  Global longitudinal strain measured by two-dimensional speckle tracking echocardiography is closely related to myocardial infarct size in chronic ischaemic heart disease.

Authors:  Ola Gjesdal; Einar Hopp; Trond Vartdal; Ketil Lunde; Thomas Helle-Valle; Svend Aakhus; Hans-Jørgen Smith; Halfdan Ihlen; Thor Edvardsen
Journal:  Clin Sci (Lond)       Date:  2007-09       Impact factor: 6.124

View more
  3 in total

1.  Left ventricular strains correlate with aortic elastic properties in adult patients with corrected tetralogy of Fallot (Results from the CSONGRAD Registry and MAGYAR-Path Study).

Authors:  Gergely Rácz; Árpád Kormányos; Péter Domsik; Anita Kalapos; Nándor Gyenes; Kálmán Havasi; Nóra Ambrus; István Hartyánszky; Gábor Bogáts; Attila Nemes
Journal:  Cardiovasc Diagn Ther       Date:  2021-04

2.  Long-term follow-up and sex differences in adults operated for tetralogy of Fallot.

Authors:  Alessia Quattrone; Oyvind H Lie; Eirik Nestaas; Charlotte de Lange; Kirsti Try; Harald L Lindberg; Helge Skulstad; Gunnar Erikssen; Thor Edvardsen; Kristina Haugaa; Mette E Estensen
Journal:  Open Heart       Date:  2021-10

3.  Biventricular strain and strain rate impairment shortly after surgical repair of tetralogy of Fallot in children: A case-control study.

Authors:  Bahar Dehghan; Alireza Ahmadi; Shima Sarfarazi Moghadam; Mohammad Reza Sabri; Mehdi Ghaderian; Chehreh Mahdavi; Mohsen Sedighi; Hamid Bigdelian
Journal:  Health Sci Rep       Date:  2022-05-03
  3 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.