Literature DB >> 30097730

Occult intra-operative periprosthetic fractures of the acetabulum may affect implant survival.

Dietmar Dammerer1, David Putzer2, Bernhard Glodny3, Johannes Petersen3, Ferdi Arrich1, Martin Krismer1, Rainer Biedermann4.   

Abstract

PURPOSE: Occult intra-operative periprosthetic acetabular fracture is a seldom-reported complication of primary total hip arthroplasty (THA). It may potentially be associated with cup instability and implant loosening. The present study aimed to investigate clinical consequences of this complication.
METHODS: Between 2003 and 2012, a total of 3390 cementless total hip arthroplasties (THA) were performed at our institution. Their medical histories were retrospectively reviewed to identify all patients who received a thin-layer computer tomography (CT) scan of the pelvis including the acetabulum within the first 30 post-operative days. They were evaluated and classified by two radiologists independently with respect to the presence of recent acetabular fractures. All cases with acetabular and periacetabular fractures were included in this study. Electronic medical records were reviewed to assess implant revision. Cup stability was measured with EBRA (Einzel-Bild-Röntgen-Analyse) from plain X-rays.
RESULTS: Periprosthetic fractures of the acetabulum were identified in 58 (50.4%) of 115 selected patients. Fractures close to but not including the acetabulum were identified in 45% (n = 26/58) of the patients, at the superolateral wall in 17% (n = 10/58), at the anterior wall of the acetabulum in 16% (n = 9/58) and in 10% (n = 6/58) each at the medial wall, and at the posterior wall respectively. One out of these 58 fractures could not be classified. Three of a total of six occult medial wall fractures had to be revised, and another two showed a high implant migration. The highest cup migration values however were found after fractures of the superolateral wall. Incomplete column fractures did not influence implant survival.
CONCLUSION: Central wall acetabular fractures, although unrecognized intra- and post-operatively may impair implant survival after THA.

Entities:  

Keywords:  Acetabular fractures; Cup migration; Einzel-Bild-Röntgen-Analyse (EBRA); Periprosthetic fractures; Total hip arthroplasty; Total hip replacement

Mesh:

Year:  2018        PMID: 30097730     DOI: 10.1007/s00264-018-4084-7

Source DB:  PubMed          Journal:  Int Orthop        ISSN: 0341-2695            Impact factor:   3.075


  8 in total

1.  Outcomes of cerclage wiring to manage intra-operative femoral fracture occurring during cementless hemiarthroplasty in older patients with femoral neck fractures.

Authors:  Aasis Unnanuntana; Nakarin Saiyudthong
Journal:  Int Orthop       Date:  2019-04-09       Impact factor: 3.075

2.  Management of Paprosky type three B acetabular defects by custom-made components: early results.

Authors:  Alessandro Aprato; Matteo Giachino; Paolo Bedino; Danilo Mellano; Raimondo Piana; Alessandro Massè
Journal:  Int Orthop       Date:  2018-10-16       Impact factor: 3.075

Review 3.  Acetabular reinforcement rings associated with allograft for severe acetabular defects.

Authors:  Emmanuel Gibon; Luc Kerboull; Jean-Pierre Courpied; Moussa Hamadouche
Journal:  Int Orthop       Date:  2018-09-13       Impact factor: 3.075

4.  Occult periprosthetic femoral fractures occur frequently during a long, trapezoidal, double-tapered cementless femoral stem fixation in primary THA.

Authors:  Ho Hyun Yun; Jung Taek Lim; Se-Hyun Yang; Phil Sun Park
Journal:  PLoS One       Date:  2019-09-19       Impact factor: 3.240

5.  Good mid-term results with the trident peripheral self-locking cup: a clinical evaluation and migration measurement with EBRA.

Authors:  Dietmar Dammerer; Philipp Blum; David Putzer; Andreas Tscholl; Michael C Liebensteiner; Martin Thaler
Journal:  Arch Orthop Trauma Surg       Date:  2020-11-09       Impact factor: 3.067

6.  Relationship Between Acetabular Hounsfield Unit Values and Periprosthetic Fractures in Cementless Total Hip Arthroplasty: A Matched Case-Control Study.

Authors:  Masanori Nishi; Ichiro Okano; Yasushi Yoshikawa; Hidenori Tochio; Yuki Usui; Katsunori Inagaki
Journal:  Arthroplast Today       Date:  2022-01-17

7.  Fixation, sex, and age: highest risk of revision for uncemented stems in elderly women - data from 66,995 primary total hip arthroplasties in the Norwegian Arthroplasty Register.

Authors:  Håvard Dale; Sjur Børsheim; Torbjørn Berge Kristensen; Anne Marie Fenstad; Jan-Erik Gjertsen; Geir Hallan; Stein Atle Lie; Ove Furnes
Journal:  Acta Orthop       Date:  2019-10-30       Impact factor: 3.717

8.  A Comparison of Risks and Benefits Regarding Hip Arthroplasty Fixation.

Authors:  Julia Matthias; Mathias P Bostrom; Joseph M Lane
Journal:  J Am Acad Orthop Surg Glob Res Rev       Date:  2021-11-01
  8 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.