Chang Ho Yoon1,2, Mee Kum Kim1,3.
Abstract
PURPOSE: To investigate the effect of surgically induced corneal astigmatism (SICA) and total corneal astigmatism (TCA) estimation on the anterior corneal astigmatism (ACA)-based toric intraocular lens (IOL) calculation.Entities:
Keywords: Astigmatism; Lenses, intraocular; Surgically induced corneal astigmatism; Toric
Mesh:
Year: 2018 PMID: 30091304 PMCID: PMC6085185 DOI: 10.3341/kjo.2017.0108
Source DB: PubMed Journal: Korean J Ophthalmol ISSN: 1011-8942
Subject characteristics and postoperative results
WTRA = with the rule anterior corneal astigmatism; ATRA = against the rule anterior corneal astigmatism; D = diptor; SD = standard deviation; IOL = intraocular lens.
*Chi-square exact test; †Independent t-test; ‡Fisher exact test.
Vector analysis of astigmatism in the whole sample
Values are presented as means ± standard deviations or vectors.
SIA = surgically induced astigmatism; D = diopter; TIA = target induced astigmatism; DV = difference vector.
*Repeated-measure one-way analysis of variance.
Vector analysis of astigmatism in eyes with WTRA
Values are presented as means ± standard deviations or vectors.
WTRA = with the rule anterior corneal astigmatism; SIA = surgically induced astigmatism; D = diopter; TIA = target induced astigmatism; DV = difference vector.
*Repeated-measure one-way analysis of variance.
Vector analysis of astigmatism in eyes with ATRA
Values are presented as means ± standard deviations or vectors.
ATRA = against the rule anterior corneal astigmatism; SIA = Surgically induced astigmatism; D = diopter; TIA = target induced astigmatism; DV = difference vector.
*Repeated-measure one-way analysis of variance.
Fig. 1Double-angle plots of the difference vector with 95% confidence ellipses in eyes with with the rule anterior corneal astigmatism (red) and those with against the rule anterior corneal astigmatism (blue) in models 1 through 5.