Literature DB >> 26215437

Toric Intraocular Lens Calculations Using Ratio of Anterior to Posterior Corneal Cylinder Power.

Youngsub Eom1, Jay Won Rhim1, Su-Yeon Kang1, Seong-Woo Kim1, Jong Suk Song1, Hyo Myung Kim2.   

Abstract

PURPOSE: To evaluate the accuracy of toric intraocular lens (IOL) calculation using estimated total corneal astigmatism based on the anterior-to-posterior corneal cylinder power ratio according to the axis orientation of anterior corneal astigmatism.
DESIGN: Retrospective cross-sectional study.
METHODS: Nine hundred twenty-eight eyes of 928 reference subjects and 20 cataract patients (20 eyes) implanted with a toric IOL were enrolled. Linear regression analysis parameters (β0 and β1) of relationship between the simulated keratometry cylinder (CylSimK) and posterior corneal cylinder power of reference subjects were used to calculate the estimated posterior corneal astigmatism (-[β1 × CylSimK + β0] @ 90). When regression analysis was not significant, estimated posterior corneal astigmatism was defined as the negative value of the mean posterior corneal cylinder power @ 90. Estimated total corneal astigmatism was defined as the vectorial sum of anterior corneal astigmatism and estimated posterior corneal astigmatism. Residual astigmatism error, predicted using SimK, was compared with that predicted using estimated total corneal astigmatism.
RESULTS: Estimated posterior corneal astigmatism was determined to be -(0.15 × CylSimK + 0.22) @ 90 in eyes with with-the-rule astigmatism, -(0.05 × CylSimK + 0.27) @ 90 in oblique astigmatism, and -0.27 @ 90 in against-the-rule astigmatism. The median magnitude of the predicted residual astigmatism error calculated using estimated total corneal astigmatism (0.30 cylinder diopters) was significantly smaller than that calculated with SimK (0.50 cylinder diopters).
CONCLUSIONS: Toric IOL calculations using estimated total corneal astigmatism based on the anterior-to-posterior corneal cylinder power ratio provided a more appropriate toric IOL cylinder power than calculations using SimK astigmatism.
Copyright © 2015 Elsevier Inc. All rights reserved.

Entities:  

Mesh:

Year:  2015        PMID: 26215437     DOI: 10.1016/j.ajo.2015.07.011

Source DB:  PubMed          Journal:  Am J Ophthalmol        ISSN: 0002-9394            Impact factor:   5.258


  12 in total

1.  Comparison of Barrett Toric Calculations Using Measured and Predicted Posterior Corneal Astigmatism in Cataract Surgery Patients.

Authors:  Mark K Lukewich; Fahmeeda Murtaza; Sohel Somani; Eric S Tam; Hannah H Chiu
Journal:  Clin Ophthalmol       Date:  2022-06-01

2.  Effects of posterior corneal astigmatism on the accuracy of AcrySof toric intraocular lens astigmatism correction.

Authors:  Bin Zhang; Jing-Xue Ma; Dan-Yan Liu; Cong-Rong Guo; Ying-Hua Du; Xiu-Jin Guo; Yue-Xian Cui
Journal:  Int J Ophthalmol       Date:  2016-09-18       Impact factor: 1.779

3.  Development of a program for toric intraocular lens calculation considering posterior corneal astigmatism, incision-induced posterior corneal astigmatism, and effective lens position.

Authors:  Youngsub Eom; Dongok Ryu; Dae Wook Kim; Seul Ki Yang; Jong Suk Song; Sug-Whan Kim; Hyo Myung Kim
Journal:  Graefes Arch Clin Exp Ophthalmol       Date:  2016-08-19       Impact factor: 3.117

4.  Comparing refractive outcomes of a standard industry toric IOL calculator using anterior corneal astigmatism and total corneal refractive power.

Authors:  C Kern; L El Kaissi; K Kortuem; M Shajari; E Vounotrypidis; A Langenbucher; S Priglinger; W J Mayer
Journal:  Graefes Arch Clin Exp Ophthalmol       Date:  2019-12-20       Impact factor: 3.117

5.  Clinical outcomes with toric intraocular lenses planned using an optical low coherence reflectometry ocular biometer with a new toric calculator.

Authors:  Kjell G Gundersen; Richard Potvin
Journal:  Clin Ophthalmol       Date:  2016-11-03

6.  Agreement between total corneal astigmatism calculated by vector summation and total corneal astigmatism measured by ray tracing using Galilei double Scheimpflug analyzer.

Authors:  Sepehr Feizi; Siamak Delfazayebaher; Vahid Ownagh; Fatemeh Sadeghpour
Journal:  J Optom       Date:  2017-08-04

7.  Improving the Toric Intraocular Lens Calculation by Considering Posterior Corneal Astigmatism and Surgically-induced Corneal Astigmatism.

Authors:  Chang Ho Yoon; Mee Kum Kim
Journal:  Korean J Ophthalmol       Date:  2018-08

8.  Comparison of Two Toric IOL Calculation Methods.

Authors:  C Kern; K Kortüm; M Müller; A Kampik; S Priglinger; W J Mayer
Journal:  J Ophthalmol       Date:  2018-01-10       Impact factor: 1.909

9.  Mean Posterior Corneal Power and Astigmatism in Normal Versus Keratoconic Eyes.

Authors:  Sepehr Feizi; Siamak Delfazayebaher; Mohammad Ali Javadi; Farid Karimian; Vahid Ownagh; Fatemeh Sadeghpour
Journal:  J Ophthalmic Vis Res       Date:  2018 Apr-Jun

10.  Comparison of Anterior, Posterior, and Total Corneal Astigmatism Measured Using a Single Scheimpflug Camera in Healthy and Keratoconus Eyes.

Authors:  Young Choi; Youngsub Eom; Jong Suk Song; Hyo Myung Kim
Journal:  Korean J Ophthalmol       Date:  2018-05-15
View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.