Literature DB >> 30084261

Beam hardening correction tool improves the diagnosis of incipient caries lesions in Micro-CT images.

Karla Rovaris1, Saulo Leonardo Sousa Melo2, Polyane Mazucatto Queiroz1, Carolina Loch3, Donald R Schwass3, Francisco Haiter-Neto1.   

Abstract

OBJECTIVE: To evaluate the effect of Beam Hardening Correction tool (BHC) on Micro-CT images used in the diagnosis of incipient caries lesions.
METHODS: Six posterior teeth, with 6 sound proximal surfaces and 6 natural white spot lesions, were scanned using a SkyScan1174 device. Each tooth was imaged 16 times in various acquisition parameters, and reconstructed 3 times applying different levels of BHC (0, 15 and 30%). The 288 datasets were analyzed by three examiners. Gold-standard was obtained by microscopic analyses under polarized light. Area under the ROC curve was obtained for each protocol and the BHC parameter was isolated to individually observe the influence of such parameters of reconstruction.
RESULTS: Microtomographic images were accurate for the diagnosis of incipient caries lesions even when the BHC tool was not applied. Accuracy was perfect in 50 % of the protocols without BHC. When adding the artefact correction, the number of protocols that reached perfect accuracy increased to 81.25%. No difference was found between the protocols that used 15 or 30% BHC. Statistically significant differences were found only in four comparisons, and on those the images that had BHC were more accurate. Two non-BHC protocols reached accuracy scores of 0.653 and 0.881, and were improved to perfect accuracy with BHC application.
CONCLUSION: The use of the BHC tool should be encouraged when using Micro-CT to detect incipient caries lesions, especially when low-quality parameters aiming less acquisition and processing time are used.

Entities:  

Mesh:

Year:  2018        PMID: 30084261      PMCID: PMC6398906          DOI: 10.1259/dmfr.20180123

Source DB:  PubMed          Journal:  Dentomaxillofac Radiol        ISSN: 0250-832X            Impact factor:   2.419


  22 in total

1.  An X-ray microtomographic study of natural white-spot enamel lesions.

Authors:  N J Cochrane; P Anderson; G R Davis; G G Adams; M A Stacey; E C Reynolds
Journal:  J Dent Res       Date:  2011-11-17       Impact factor: 6.116

Review 2.  Application of polychromatic µCT for mineral density determination.

Authors:  W Zou; N Hunter; M V Swain
Journal:  J Dent Res       Date:  2010-09-21       Impact factor: 6.116

3.  Accuracy of microCT in the quantitative determination of the degree and distribution of mineralization in developing bone.

Authors:  L Mulder; J H Koolstra; T M G J Van Eijden
Journal:  Acta Radiol       Date:  2004-11       Impact factor: 1.990

4.  Mineral concentration of natural human teeth by a commercial micro-CT.

Authors:  Tatiana Nogueira Rocha Clementino-Luedemann; Karl-Heinz Kunzelmann
Journal:  Dent Mater J       Date:  2006-03       Impact factor: 2.102

5.  The measurement of observer agreement for categorical data.

Authors:  J R Landis; G G Koch
Journal:  Biometrics       Date:  1977-03       Impact factor: 2.571

6.  Diagnostic performance of the visual caries classification system ICDAS II versus radiography and micro-computed tomography for proximal caries detection: an in vitro study.

Authors:  P Mitropoulos; C Rahiotis; H Stamatakis; A Kakaboura
Journal:  J Dent       Date:  2010-07-21       Impact factor: 4.379

7.  An automated assessment algorithm for micro-CT images of occlusal caries.

Authors:  Andrew M Taylor; Julian D Satterthwaite; Roger P Ellwood; Iain A Pretty
Journal:  Surgeon       Date:  2010-07-22       Impact factor: 2.392

8.  Reproducibility and accuracy of the ICDAS-II for detection of occlusal caries in vitro.

Authors:  A Jablonski-Momeni; V Stachniss; D N Ricketts; M Heinzel-Gutenbrunner; K Pieper
Journal:  Caries Res       Date:  2008-01-15       Impact factor: 4.056

9.  Detection of non-cavitated approximal caries lesions in digital images from seven solid-state receptors with particular focus on task-specific enhancement filters. An ex vivo study in human teeth.

Authors:  Francisco Haiter-Neto; Andrea dos Anjos Pontual; Morten Frydenberg; Ann Wenzel
Journal:  Clin Oral Investig       Date:  2008-01-22       Impact factor: 3.573

10.  Morphometric analysis of human bone biopsies: a quantitative structural comparison of histological sections and micro-computed tomography.

Authors:  R Müller; H Van Campenhout; B Van Damme; G Van Der Perre; J Dequeker; T Hildebrand; P Rüegsegger
Journal:  Bone       Date:  1998-07       Impact factor: 4.398

View more
  2 in total

1.  Does the addition of a lead foil to digital radiographic receptors influence image contrast and approximal caries lesions diagnosis?

Authors:  Rocharles Cavalcante Fontenele; Yuri Nejaim; Amanda Farias Gomes; Hugo Gaêta-Araujo; Francisco Haiter-Neto; Deborah Queiroz Freitas
Journal:  Dentomaxillofac Radiol       Date:  2020-02-06       Impact factor: 2.419

2.  Validity of micro-CT for in vitro caries detection: a systematic review and meta-analysis.

Authors:  Luciana Butini Oliveira; Carla Massignan; Anne Caroline Oenning; Karla Rovaris; Michele Bolan; André Luís Porporatti; Graziela De Luca Canto
Journal:  Dentomaxillofac Radiol       Date:  2019-11-20       Impact factor: 2.419

  2 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.