Literature DB >> 30081355

Importance of asymmetry and anisotropy in predicting cortical bone response and fracture using human body model femur in three-point bending and axial rotation.

F Khor1, D S Cronin2, B Watson1, D Gierczycka1, S Malcolm3.   

Abstract

Modeling of cortical bone response and failure is critical for the prediction of Crash Induced Injuries (CII) using advanced finite element (FE) Human Body Models (HBM). Although cortical bone is anisotropic and asymmetric in tension and compression, current HBM often utilize simple isotropic, symmetric, elastic-plastic constitutive models. In this study, a 50th percentile male femur FE model was used to quantify the effect of asymmetry and anisotropy in three-point bending and axial torsion. A complete set of cortical bone mechanical properties was identified from a literature review, and the femur model was used to investigate the importance of material asymmetry and anisotropy on the failure load/moment, failure displacement/rotation and fracture pattern. All models were able to predict failure load in bending, since this was dominated by the cortical bone material tensile response. However, only the orthotropic model was able to predict the torsional response and failure moment. Only the orthotropic model predicted the fracture initiation location and fracture pattern in bending, and the fracture initiation location in torsion; however, the anticipated spiral fracture pattern was not predicted by the models for torsional loading. The results demonstrated that asymmetry did not significantly improve the prediction capability, and that orthotropic material model with the identified material properties was able to predict the kinetics and kinematics for both three-point bending and axial torsion. This will help to provide an improved method for modeling hard tissue response and failure in full HBM.
Copyright © 2018 Elsevier Ltd. All rights reserved.

Entities:  

Keywords:  Constitutive model; Femur; Finite element model; Fracture pattern; Hard tissue; Human body model

Mesh:

Year:  2018        PMID: 30081355     DOI: 10.1016/j.jmbbm.2018.07.033

Source DB:  PubMed          Journal:  J Mech Behav Biomed Mater        ISSN: 1878-0180


  4 in total

1.  Assessing the Elasticity of Child Cortical Bone.

Authors:  Cécile Baron; Hélène Follet; Martine Pithioux; Cédric Payan; Philippe Lasaygues
Journal:  Adv Exp Med Biol       Date:  2022       Impact factor: 2.622

2.  Cement augmentation of the proximal femoral nail antirotation for the treatment of two intertrochanteric fractures - a comparative finite element study.

Authors:  Liqin Zheng; Xinmin Chen; Yongze Zheng; Xingpeng He; Jingxiong Wu; Ziling Lin
Journal:  BMC Musculoskelet Disord       Date:  2021-12-02       Impact factor: 2.362

3.  Two Cannulated Screws Provide Sufficient Biomechanical Strength for Prophylactic Fixation in Adult Patients With an Aggressive Benign Femoral Neck Lesion.

Authors:  Guangtao Fu; Guoqing Zhong; Zehong Yang; Shi Cheng; Limin Ma; Yu Zhang
Journal:  Front Bioeng Biotechnol       Date:  2022-07-07

4.  Effect of Domain Size, Boundary, and Loading Conditions on Mechanical Properties of Amorphous Silica: A Reactive Molecular Dynamics Study.

Authors:  Truong Vo; Brett Reeder; Angelo Damone; Pania Newell
Journal:  Nanomaterials (Basel)       Date:  2019-12-25       Impact factor: 5.076

  4 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.