| Literature DB >> 30076690 |
Shivani Kumar1,2,3, Lois Holloway1,2,3,4,5, Dale Roach1,2,3, Elise Pogson2,3,4,5, Jacqueline Veera6, Vikneswary Batumalai1,2,3, Karen Lim1,2, Geoff P Delaney1,2,3,7, Elizabeth Lazarus8, Nira Borok8, Daniel Moses9,10, Michael G Jameson1,2,3, Shalini Vinod1,2.
Abstract
INTRODUCTION: Magnetic resonance imaging (MRI) is increasingly used for target volume delineation in radiotherapy due to its superior soft tissue visualisation compared to computed tomography (CT). The aim of this study was to assess the impact of a radiologist-led workshop on inter-observer variability in volume delineation on MRI.Entities:
Keywords: Education; MRI; inter-observer variability; target volume delineation; training
Mesh:
Year: 2018 PMID: 30076690 PMCID: PMC6275253 DOI: 10.1002/jmrs.298
Source DB: PubMed Journal: J Med Radiat Sci ISSN: 2051-3895
Imaging parameters for all three clinical sites
| MRI acquisition parameters | Clinical sites | ||
|---|---|---|---|
| Lung | Breast | Cervix | |
| Scanner |
1.5T (Ge Signa HDE) | 3T (Siemens Medical Systems, Erlangen, Germany) |
1.5T (Symphony, Siemens medical Systems, Erlangen Germany) |
| Receiver coils | 8‐channel surface coil |
Supine : 18‐channel surface coil | 6‐channel surface coil |
| Imaging sequence |
T2: SSFSE | T2: TSE | T2: 3D TSE (SPACE) |
| Acquisition plane | Transverse | Transverse | Transverse |
| Slice thickness | 6 mm | 2 mm | 2.5 mm |
SSFSE, single‐shot fast‐spin echo; LAVA, Liver acquisition with volume acceleration; TSE, turbo‐spin echo; SPACE, sampling perfection with application optimised contrast.
Figure 1Definition of contour analysis metrics. * A VOLSIM value of > 0 indicates observer volume is larger than reference volume and < 0 indicated observe volume is smaller than reference volume. This index does not take into account any overlap measure.
Figure 2Individual observer contour volumes for each clinical site and volume delineated pre‐ and post‐workshop. T2GTVp, T2‐weighted primary gross tumour volume; T1GTVp, T1‐weighted primary gross tumour volume; T2GTVn, T2‐weighted nodal gross tumour volume; T1GTVn, T1‐weighted nodal gross tumour volume; CTV, clinical target volume; Pre, pre‐workshop volume; post, post‐workshop volume.
Figure 3Volume similarity boxplot for all clinical sites. *Indicates outlier observer scores. VOLSIM, volume similarity.
Figure 4Lung DSC boxplots of the three lung cases for all observers. DSC, dice similarity coefficient.
Figure 5Breast DSC boxplots for all observers. *Indicates outlier observer score. DCS, dice similarity coefficient; CTV, clinical target volume.
Figure 6Cervix DSC boxplot for all observers. *Indicates outlier observer score. DCS, dice similarity coefficient; GTV, gross tumour volumes; CTV, clinical target volume.