Literature DB >> 30071466

Investigating the utility of minimized sample preparation and high-resolution mass spectrometry for quantification of monoclonal antibody drugs.

Tam T T N Nguyen1, Ulrik H Mistarz2, Narciso Costa3, Amaury Herbet3, Didier Boquet3, François Becher4, Kasper D Rand5.   

Abstract

Determination of the pharmacokinetic (PK) properties of therapeutic monoclonal antibodies (mAbs) is essential for their successful development as drugs. For this purpose, besides the traditional ligand binding assay (LBA), LC-MS/MS method using low resolution mass spectrometers (e.g. triple quadrupole (QqQ)) has become routinely used, however, complicated and lengthy sample pre-treatment (employing immuno-affinity) is often necessary for obtaining sufficient sensitivity and selectivity. In this study, we investigate the capabilities of high-resolution MS instruments for circumventing the complex sample preparation currently needed for sensitive LC-MS/MS-based quantification of mAbs. Employing a simple one-step sample pre-treatment workflow, we compare the ability of three different LC-MS platforms for absolute quantification of a representative monoclonal antibody Rendomab-B1 in serum and plasma. The samples are subjected to protein precipitation with methanol, followed by pellet digestion with trypsin prior to LC-MS analysis. AQUA peptides based on two surrogate mAb peptides selected from an extensive in-silico and experimental screening are used as internal standards. MS/MS acquisitions are developed and systematically examined for 1) a low-resolution QqQ operated in selected reaction monitoring (SRM) acquisition mode, 2) a high-resolution hybrid Quadrupole-Orbitrap (Q-Orbitrap) operated in parallel reaction monitoring (PRM) acquisition mode and 3) a high-resolution hybrid Quadrupole-Time-of-flight (Q-TOF) operated in SRM acquisition mode with enhanced duty cycle (EDC) function. The sensitivity of the high-resolution Q-Orbitrap and Q-TOF methods was significantly higher (LOD of 80 ng/mL) in serum/plasma samples than the low-resolution QqQ method. Finally, the real-world utility of the developed high-resolution MS method with minimized sample handling was demonstrated and validated by determining the PK profile of Rendomab-B1 in mice by a 10-point in vivo study over 15 days.
Copyright © 2018 Elsevier B.V. All rights reserved.

Entities:  

Keywords:  Bioanalysis; High resolution; Mass spectrometry; Pharmacokinetic; Therapeutic monoclonal antibody

Mesh:

Substances:

Year:  2018        PMID: 30071466     DOI: 10.1016/j.jpba.2018.07.012

Source DB:  PubMed          Journal:  J Pharm Biomed Anal        ISSN: 0731-7085            Impact factor:   3.935


  2 in total

1.  Pharmacokinetic Analysis of a Novel Human EGFRvIII:CD3 Bispecific Antibody in Plasma and Whole Blood Using a High-Resolution Targeted Mass Spectrometry Approach.

Authors:  Teilo H Schaller; Matthew W Foster; J Will Thompson; Ivan Spasojevic; Deimante Normantaite; M Arthur Moseley; Luis Sanchez-Perez; John H Sampson
Journal:  J Proteome Res       Date:  2019-07-19       Impact factor: 4.466

2.  Investigating surrogate cerebrospinal fluid matrix compositions for use in quantitative LC-MS analysis of therapeutic antibodies in the cerebrospinal fluid.

Authors:  Jens Rose Fogh; Anne-Marie Jacobsen; Tam T T N Nguyen; Kasper D Rand; Line Rørbæk Olsen
Journal:  Anal Bioanal Chem       Date:  2020-02-01       Impact factor: 4.142

  2 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.