RATIONALE AND
OBJECTIVES: Many medical specialties have incorporated portable ultrasound into their educational curriculum. Our objective was to determine the utility of an individual smart portable ultrasound device (iSPUD) as an educational tool in resident and fellowship Musculoskeletal Radiology training.
MATERIALS AND METHODS: After Institutional Review Board approval, volunteer radiology trainees were instructed to use the iSPUD (Philips Lumify ultrasound probe and Samsung Galaxy Tab S2 8 inch tablet), asked to identify 10 wrist structures with the iSPUD and completed a Likert scale-based, pretest survey. Trainees were then given the iSPUD for 3 days of independent scanning practice. Afterward, trainees were asked to identify the same 10 wrist structures with the iSPUD and to complete a Likert scale-based, post-test survey.
RESULTS: Twenty trainees volunteered to participate. Trainee performance on the 10-wrist structure identification test with the iSPUD resulted in a pretest mean number correct of 2.5 ± 2.16 and a post-test mean number correct of 9.85 ± 0.37 (p < 0.001). On the pretest survey, 68.42% (13/20) had never performed and 42.11% (8/20) had never interpreted a musculoskeletal ultrasound. On the post-test survey, 18/20 (94.74%) strongly agreed that access to an iSPUD would improve their ability to perform musculoskeletal ultrasound, improve ultrasound-guided interventional skills, and help them become better Radiologists.
CONCLUSION: The use of an iSPUD as a tool in Musculoskeletal Radiology resident and fellow education can improve clinical ultrasound skills, build trainee technical confidence during diagnostic ultrasound procedures, and help trainees achieve their goal of becoming a competent Radiologist.
Copyright © 2018. Published by Elsevier Inc.

Keywords:  Abbreviations List: ECRB, extensor carpi radialis brevis; ECRL, extensor carpi radialis longus; EPL, extensor pollicis longus; FPL, flexor pollicis longus; MSK, musculoskeletal; PGY, postgraduate year; SLL, scapholunate ligament; UA, ulnar artery; US, ultrasound; iSPUD, individual smart portable ultrasound

Mesh:

Year:  2018        PMID: 30064918     DOI: 10.1016/j.acra.2018.06.005

Source DB:  PubMed          Journal:  Acad Radiol        ISSN: 1076-6332            Impact factor:   3.173


  3 in total

1.  ESR statement on portable ultrasound devices.

Authors: 
Journal:  Insights Imaging       Date:  2019-09-16

2.  Hand-Held Portable Versus Conventional Cart-Based Ultrasound in Musculoskeletal Imaging.

Authors:  Anna L Falkowski; Jon A Jacobson; Michael T Freehill; Vivek Kalia
Journal:  Orthop J Sports Med       Date:  2020-02-12

3.  Performance of a Handheld Ultrasound Device to Assess Articular and Periarticular Pathologies in Patients with Inflammatory Arthritis.

Authors:  Giulia Corte; Sara Bayat; Koray Tascilar; Larissa Valor-Mendez; Louis Schuster; Johannes Knitza; Filippo Fagni; Georg Schett; Arnd Kleyer; David Simon
Journal:  Diagnostics (Basel)       Date:  2021-06-22
  3 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.