Literature DB >> 30049358

The Emerging Role of Wearable Technologies in Detection of Arrhythmia.

Christopher C Cheung1, Andrew D Krahn1, Jason G Andrade2.   

Abstract

Over the past decade, there has been an explosion of consumer devices for the purposes of health and fitness tracking. The wearable technology market, composed of devices that monitor physiological parameters, such as heart rate and sleep pattern, is anticipated to grow to 929 million connected devices in 2021. These devices encompass wristbands, glasses, in-ear monitors, or electronic shirts, with varying capacity to monitor heart rate, heart rhythm, blood pressure, physical activity, respiratory rate, blood glucose, and sleep patterns. For heart-rate monitoring, most wearable devices use photoplethysmography (PPG) technology, meaning they are inherently less accurate than conventional electrocardiography monitoring techniques (reference standard). However, a growing body of evidence suggests that these technologies can be harnessed to facilitate arrhythmia detection in the appropriate context. Studies evaluating PPG-based wearables in conjunction with machine-learning algorithms have shown promise in detection of such arrhythmias, as atrial fibrillation. Limitations of wearable technologies include their accuracy and accessibility and the clinical implications of wearable-detected arrhythmias. Despite this, wearable technologies represent an important frontier in health evaluation. Future wearables will benefit from improved reliability and accuracy, collect additional health and fitness parameters, support management of chronic disease, and provide real-time connectivity and feedback that may supplant conventional medical monitoring. Wearables have the potential to become truly disruptive in our health care sector, with large segments of the population soon to have readily available health data that the physician must interpret.
Copyright © 2018 Canadian Cardiovascular Society. Published by Elsevier Inc. All rights reserved.

Entities:  

Mesh:

Year:  2018        PMID: 30049358     DOI: 10.1016/j.cjca.2018.05.003

Source DB:  PubMed          Journal:  Can J Cardiol        ISSN: 0828-282X            Impact factor:   5.223


  17 in total

1.  Is It Safe (and When) to Stop Oral Anticoagulation After Ablation for Atrial fibrillation? (Do We Have Enough Evidence to Solve the Dilemma?).

Authors:  José Luis Merino; Juan Tamargo
Journal:  Cardiovasc Drugs Ther       Date:  2021-09-07       Impact factor: 3.727

2.  European Heart Rhythm Association (EHRA)/Heart Rhythm Society (HRS)/Asia Pacific Heart Rhythm Society (APHRS)/Latin American Heart Rhythm Society (LAHRS) expert consensus on risk assessment in cardiac arrhythmias: use the right tool for the right outcome, in the right population.

Authors:  Jens Cosedis Nielsen; Yenn-Jiang Lin; Marcio Jansen de Oliveira Figueiredo; Alireza Sepehri Shamloo; Alberto Alfie; Serge Boveda; Nikolaos Dagres; Dario Di Toro; Lee L Eckhardt; Kenneth Ellenbogen; Carina Hardy; Takanori Ikeda; Aparna Jaswal; Elizabeth Kaufman; Andrew Krahn; Kengo Kusano; Valentina Kutyifa; Han S Lim; Gregory Y H Lip; Santiago Nava-Townsend; Hui-Nam Pak; Gerardo Rodríguez Diez; William Sauer; Anil Saxena; Jesper Hastrup Svendsen; Diego Vanegas; Marmar Vaseghi; Arthur Wilde; T Jared Bunch; Alfred E Buxton; Gonzalo Calvimontes; Tze-Fan Chao; Lars Eckardt; Heidi Estner; Anne M Gillis; Rodrigo Isa; Josef Kautzner; Philippe Maury; Joshua D Moss; Gi-Byung Nam; Brian Olshansky; Luis Fernando Pava Molano; Mauricio Pimentel; Mukund Prabhu; Wendy S Tzou; Philipp Sommer; Janice Swampillai; Alejandro Vidal; Thomas Deneke; Gerhard Hindricks; Christophe Leclercq
Journal:  Europace       Date:  2020-08-01       Impact factor: 5.214

3.  Diagnostic Utility of Smartwatch Technology for Atrial Fibrillation Detection - A Systematic Analysis.

Authors:  Mehmet Ali Elbey; Daisy Young; Sri Harsha Kanuri; Krishna Akella; Ghulam Murtaza; Jalaj Garg; Donita Atkins; Sudha Bommana; Sharan Sharma; Mohit Turagam; Jayashree Pillarisetti; Peter Park; Rangarao Tummala; Alap Shah; Scott Koerber; Poojita Shivamurthy; Chandrasekhar Vasamreddy; Rakesh Gopinathannair; Dhanunjaya Lakkireddy
Journal:  J Atr Fibrillation       Date:  2021-04-30

4.  Recommendations for determining the validity of consumer wearable heart rate devices: expert statement and checklist of the INTERLIVE Network.

Authors:  Jan M Mühlen; Julie Stang; Esben Lykke Skovgaard; Pedro B Judice; Pablo Molina-Garcia; William Johnston; Luís B Sardinha; Francisco B Ortega; Brian Caulfield; Wilhelm Bloch; Sulin Cheng; Ulf Ekelund; Jan Christian Brønd; Anders Grøntved; Moritz Schumann
Journal:  Br J Sports Med       Date:  2021-01-04       Impact factor: 13.800

Review 5.  Wearable Devices: Current Status and Opportunities in Pain Assessment and Management.

Authors:  Andrew Leroux; Rachael Rzasa-Lynn; Ciprian Crainiceanu; Tushar Sharma
Journal:  Digit Biomark       Date:  2021-04-19

6.  Accuracy of mHealth Devices for Atrial Fibrillation Screening: Systematic Review.

Authors:  Godwin Denk Giebel; Christian Gissel
Journal:  JMIR Mhealth Uhealth       Date:  2019-06-16       Impact factor: 4.773

7.  Training and Evaluation of Human Cardiorespiratory Endurance Based on a Fuzzy Algorithm.

Authors:  Jui-Chuan Cheng; Chao-Yuan Chiu; Te-Jen Su
Journal:  Int J Environ Res Public Health       Date:  2019-07-05       Impact factor: 3.390

Review 8.  Mobile Self-Monitoring ECG Devices to Diagnose Arrhythmia that Coincide with Palpitations: A Scoping Review.

Authors:  Hannah Ramsden Marston; Robin Hadley; Duncan Banks; María Del Carmen Miranda Duro
Journal:  Healthcare (Basel)       Date:  2019-08-16

9.  Use of a Smart Watch for Early Detection of Paroxysmal Atrial Fibrillation: Validation Study.

Authors:  Yohei Kawasaki; Tomohiko Inui; Hiroki Kohno; Kaoru Matsuura; Hideki Ueda; Yusaku Tamura; Michiko Watanabe; Yuichi Inage; Yasunori Yakita; Yutaka Wakabayashi; Goro Matsumiya
Journal:  JMIR Cardio       Date:  2020-01-22

10.  The Auxiliary Diagnostic Value of a Novel Wearable Electrocardiogram-Recording System for Arrhythmia Detection: Diagnostic Trial.

Authors:  Shaomin Zhang; Hong Xian; Yi Chen; Yue Liao; Nan Zhang; Xinyu Guo; Ming Yang; Jinhui Wu
Journal:  Front Med (Lausanne)       Date:  2021-06-24
View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.