| Literature DB >> 30049287 |
Felix Fingas1,2, Daniela Volke1,3, Petra Bielefeldt2, Rayk Hassert1,3, Ralf Hoffmann4,5.
Abstract
BACKGROUND: Reovirus type-3 infections cause severe pathologies in young mice and thus influence animal experiments in many ways. Therefore, the Federation of Laboratory Animal Science Associations (FELASA) recommends an annual screening in laboratory mice as part of a thorough health monitoring program. Based on the high protein sequence homology among the different reovirus serotypes, immunofluorescence antibody assay and other indirect methods relying on the whole virus are presumably cross-reactive to antibodies triggered by mammalian orthoreovirus infections independent of the serotype.Entities:
Keywords: ELISA; FELASA; Mammalian orthoreovirus type-3
Mesh:
Substances:
Year: 2018 PMID: 30049287 PMCID: PMC6062942 DOI: 10.1186/s12985-018-1021-8
Source DB: PubMed Journal: Virol J ISSN: 1743-422X Impact factor: 4.099
Fig. 1ELISA shows seroconversion of infected mice. Scatter blot of absorbance values obtained by a reovirus T3A-based ELISA of serum collected from BALB/c and C57BL/6 mice two, four, and six weeks after being infected with reovirus T3D and control sera. Test-specific cut-off (0.3) is indicated as a dashed line
Fig. 2IFA confirms seroconversion of reovirus T3D-infected mice. IFA based on reovirus T3D- (a-d) and reovirus T2J-infected (e + f) MA104-cells probed with anti-reovirus type-3 σ-1 monoclonal antibody (mAb, a; positive control), serum of an uninfected specific pathogen-free (SPF) mouse (b; negative control) and sera of reovirus T3D-infected BALB/c (c + e) and C57BL/6 (d + f) mice. Fluorescence staining relied on an Alexa Fluor 488-conjugated goat anti-mouse IgG antibody (green). Cell nuclei were stained with DAPI (blue). Scale bar: 50 μm
Fig. 3SDS-PAGE (a) and immunoblots (b) of recombinant Strep-rσ-1-His after purification from inclusion bodies. a Proteins were stained with colloidal Coomassie. M denotes marker proteins with the molecular masses in kDa indicated left. b Electroblot probed with a commercial anti-reovirus type-3 serum (anti-Reo-3), serum obtained from a mouse experimentally infected with reovirus T3D (Reo-T3D [+]), and a serum from an uninfected mouse (Reo-T3D [-])
Fig. 4Strep-rσ-1-His-based indirect ELISA is highly sensitive, specific and selective. Scatter blot of absorbance values recorded for reovirus T3D-infected BALB/c (filled circles, n = 15) and C57BL/6 (open circles, n = 15) mice, sera obtained from uninfected SPF mice (n = 30), and sera positive for other viral and bacterial FELASA-listed pathogens (n = 10 each). Cut-off value defined by ROC analysis (0.36) is indicated as dashed line
Diagnostic parameter of Strep-rσ-1-His indirect ELISA
| Diagnostic parameter | Value |
|---|---|
| Repeatability | PC: 5.4% CoV ( |
| Intermediate Precision | PC: 11.2% CoV ( |
| Long-term Stability | > 70 d (4 °C); < 10 d (37 °C) |
| LODref (D-SN; D-SP) | 0.31 (100%, |
| ROCref (D-SN; D-SP) | 0.36 (100%, |
| Selectivity based on ROCref | 98.8% ( |
Raw data of repeatability, intermediate precision, and long-term stability are listed in the supplement (Additional file 5). Ref Calculation based on sera of experimentally infected and control SPF mice, PC positive control, NC negative control, CoV coefficient of variation
Fig. 5Screening of field sera with Strep-rσ-1-His-ELISA. Scatter plot of absorbance values recorded at 450 nm (Abs 450 nm) using randomly collected sera from an in-house database that were partly previously tested with a commercial reovirus T3A-based ELISA. Sera are sorted according to the results of T3D-IFA. Cut-off value (0.4) is indicated as dashed line