Literature DB >> 30048155

CT angiography for depiction of complications after the Bentall procedure.

Sara Boccalini1, Laurens E Swart1, Jos A Bekkers2, Koen Nieman1,3, Gabriel P Krestin1, Ad Jjc Bogers2, Ricardo Pj Budde1,3.   

Abstract

Following a Bentall procedure, which comprises a composite replacement of both the aortic valve and the ascending aorta, the imaging modality of choice to depict known or suspected complications is CT angiography. An update and extension of the literature regarding complications after the Bentall procedure is provided. The wider availability of ECG-gating has allowed for a clearer depiction of the aortic valve and ascending aorta. This resulted not only in the identification of previously undetectable complications, but also in a more precise assessment of the pathophysiology and morphology of known ones, reducing the need for additional imaging modalities. Moreover, the possibility to combine positron emission tomography images with CT angiography offers new insights in case of suspected infection. Due to the complexity of the operation itself and concomitant or subsequent additional procedures, as well as the wide spectrum of underlying pathology, new scenarios with multiple complications can be expected.

Entities:  

Mesh:

Year:  2018        PMID: 30048155      PMCID: PMC6435056          DOI: 10.1259/bjr.20180226

Source DB:  PubMed          Journal:  Br J Radiol        ISSN: 0007-1285            Impact factor:   3.039


  17 in total

1.  An unusual case of acquired ventricular septal defect as a complication of aortic valve endocarditis: echocardiographic delineation of multiple subvalvular complications in one patient.

Authors:  K Ashmeik; R G Pai
Journal:  J Am Soc Echocardiogr       Date:  2000-07       Impact factor: 5.251

2.  2010 ACCF/AHA/AATS/ACR/ASA/SCA/SCAI/SIR/STS/SVM guidelines for the diagnosis and management of patients with Thoracic Aortic Disease: a report of the American College of Cardiology Foundation/American Heart Association Task Force on Practice Guidelines, American Association for Thoracic Surgery, American College of Radiology, American Stroke Association, Society of Cardiovascular Anesthesiologists, Society for Cardiovascular Angiography and Interventions, Society of Interventional Radiology, Society of Thoracic Surgeons, and Society for Vascular Medicine.

Authors:  Loren F Hiratzka; George L Bakris; Joshua A Beckman; Robert M Bersin; Vincent F Carr; Donald E Casey; Kim A Eagle; Luke K Hermann; Eric M Isselbacher; Ella A Kazerooni; Nicholas T Kouchoukos; Bruce W Lytle; Dianna M Milewicz; David L Reich; Souvik Sen; Julie A Shinn; Lars G Svensson; David M Williams
Journal:  Circulation       Date:  2010-03-16       Impact factor: 29.690

Review 3.  CT findings following thoracic aortic surgery.

Authors:  Baskaran Sundaram; Leslie E Quint; Himanshu J Patel; G Michael Deeb
Journal:  Radiographics       Date:  2007 Nov-Dec       Impact factor: 5.333

4.  CT appearance of thoracic aortic graft complications.

Authors:  Baskaran Sundaram; Leslie Eisenbud Quint; Smita Patel; Himanshu J Patel; G Michael Deeb
Journal:  AJR Am J Roentgenol       Date:  2007-05       Impact factor: 3.959

Review 5.  Aortic valve and ascending aorta guidelines for management and quality measures.

Authors:  Lars G Svensson; David H Adams; Robert O Bonow; Nicholas T Kouchoukos; D Craig Miller; Patrick T O'Gara; David M Shahian; Hartzell V Schaff; Cary W Akins; Joseph E Bavaria; Eugene H Blackstone; Tirone E David; Nimesh D Desai; Todd M Dewey; Richard S D'Agostino; Thomas G Gleason; Katherine B Harrington; Susheel Kodali; Samir Kapadia; Martin B Leon; Brian Lima; Bruce W Lytle; Michael J Mack; Michael Reardon; T Brett Reece; G Russell Reiss; Eric E Roselli; Craig R Smith; Vinod H Thourani; E Murat Tuzcu; John Webb; Mathew R Williams
Journal:  Ann Thorac Surg       Date:  2013-06       Impact factor: 4.330

6.  A technique for complete replacement of the ascending aorta.

Authors:  H Bentall; A De Bono
Journal:  Thorax       Date:  1968-07       Impact factor: 9.139

Review 7.  Bentall Procedure: A Systematic Review and Meta-Analysis.

Authors:  Aart Mookhoek; Nelleke M Korteland; Bardia Arabkhani; Isabelle Di Centa; Emmanuel Lansac; Jos A Bekkers; Ad J J C Bogers; Johanna J M Takkenberg
Journal:  Ann Thorac Surg       Date:  2016-02-06       Impact factor: 4.330

Review 8.  18F-fluorodeoxyglucose positron emission/computed tomography and computed tomography angiography in prosthetic heart valve endocarditis: from guidelines to clinical practice.

Authors:  Laurens E Swart; Asbjørn M Scholtens; Wilco Tanis; Koen Nieman; Ad J J C Bogers; Fred J Verzijlbergen; Gabriel P Krestin; Jolien W Roos-Hesselink; Ricardo P J Budde
Journal:  Eur Heart J       Date:  2018-11-01       Impact factor: 29.983

9.  Device closure of iatrogenic membranous ventricular septal defects after prosthetic aortic valve replacement using the Amplatzer membranous ventricular septal defect occluder.

Authors:  Ralf Holzer; Larry Latson; Ziyad M Hijazi
Journal:  Catheter Cardiovasc Interv       Date:  2004-06       Impact factor: 2.692

10.  Peri-aortic fluid after surgery on the ascending aorta: Worrisome indicator of complications or innocent postoperative finding?

Authors:  Sara Boccalini; Laurens E Swart; Jos A Bekkers; Koen Nieman; Gabriel P Krestin; Ad J J C Bogers; Ricardo P J Budde
Journal:  Eur J Radiol       Date:  2017-09-08       Impact factor: 3.528

View more
  2 in total

1.  18F-FDG PET/CT: Not only a promise for complex scenarios-let's talk about aortic grafts.

Authors:  Albert Roque; María Nazarena Pizzi
Journal:  J Nucl Cardiol       Date:  2021-12-21       Impact factor: 5.952

2.  Recurrent ascending aortic pseudoaneurysms: rare but a feared complication.

Authors:  Kaushalendra Rathore
Journal:  Indian J Thorac Cardiovasc Surg       Date:  2021-01-09
  2 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.