A 2-D Ultrasound Transducer With Front-End ASIC and Low Cable Count for 3-D Forward-Looking Intravascular Imaging: Performance and Characterization.

Jovana Janjic, Mingliang Tan, Verya Daeichin, Emile Noothout, Chao Chen, Zhao Chen, Zu-Yao Chang, Robert H S H Beurskens, Gijs van Soest, Antonius F W van der Steen, Martin D Verweij, Michiel A P Pertijs, Nico de Jong.   

Abstract

Intravascular ultrasound (IVUS) is an imaging modality used to visualize atherosclerosis from within the inner lumen of human arteries. Complex lesions like chronic total occlusions require forward-looking IVUS (FL-IVUS), instead of the conventional side-looking geometry. Volumetric imaging can be achieved with 2-D array transducers, which present major challenges in reducing cable count and device integration. In this work, we present an 80-element lead zirconium titanate matrix ultrasound transducer for FL-IVUS imaging with a front-end application-specific integrated circuit (ASIC) requiring only four cables. After investigating optimal transducer designs, we fabricated the matrix transducer consisting of 16 transmit (TX) and 64 receive (RX) elements arranged on top of an ASIC having an outer diameter of 1.5 mm and a central hole of 0.5 mm for a guidewire. We modeled the transducer using finite-element analysis and compared the simulation results to the values obtained through acoustic measurements. The TX elements showed uniform behavior with a center frequency of 14 MHz, a -3-dB bandwidth of 44%, and a transmit sensitivity of 0.4 kPa/V at 6 mm. The RX elements showed center frequency and bandwidth similar to the TX elements, with an estimated receive sensitivity of /Pa. We successfully acquired a 3-D FL image of three spherical reflectors in water using delay-and-sum beamforming and the coherence factor method. Full synthetic-aperture acquisition can be achieved with frame rates on the order of 100 Hz. The acoustic characterization and the initial imaging results show the potential of the proposed transducer to achieve 3-D FL-IVUS imaging.

Entities:  

Year:  2018        PMID: 30047876     DOI: 10.1109/TUFFC.2018.2859824

Source DB:  PubMed          Journal:  IEEE Trans Ultrason Ferroelectr Freq Control        ISSN: 0885-3010            Impact factor:   2.725


  3 in total

1.  Dual-Resonance (16/32 MHz) Piezoelectric Transducer With a Single Electrical Connection for Forward-Viewing Robotic Guidewire.

Authors:  Graham C Collins; Timothy A Brumfiel; Zachary L Bercu; Jaydev P Desai; Brooks D Lindsey
Journal:  IEEE Trans Ultrason Ferroelectr Freq Control       Date:  2022-03-30       Impact factor: 3.267

2.  A Robotically Steerable Guidewire With Forward-Viewing Ultrasound: Development of Technology for Minimally-Invasive Imaging.

Authors:  Graham C Collins; Achraj Sarma; Zachary L Bercu; Jaydev P Desai; Brooks D Lindsey
Journal:  IEEE Trans Biomed Eng       Date:  2021-06-17       Impact factor: 4.756

3.  Miniaturized 0.13-μm CMOS Front-End Analog for AlN PMUT Arrays.

Authors:  Iván Zamora; Eyglis Ledesma; Arantxa Uranga; Núria Barniol
Journal:  Sensors (Basel)       Date:  2020-02-22       Impact factor: 3.576

  3 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.