Literature DB >> 30039456

Continuous hemofiltration model using porcine blood for comparing filter life.

Yoshitaka Kurihara1, Shunichi Ueki1, Kenichi Kokubo2,3, Yuta Kobayashi1, Tomoyo Ebine1, Kaya Murakami1, Yosuke Ushiroda4, Naoko Maruyama1,5, Hiroshi Tsukao1,6, Kozue Kobayashi1,6, Hirosuke Kobayashi7,8.   

Abstract

The purpose of the present study was to establish a continuous hemofiltration model using porcine blood to compare filter life. Continuous hemofiltration (CHF) experiments were performed using an in vitro hemofilter evaluation system utilizing porcine blood containing trisodium citrate in addition to nafamostat mesilate as anticoagulants. The lifetime of the hemofilter was evaluated using the transmembrane pressure and the pressure drop across the hemofilter at varying trisodium citrate concentrations. The porcine blood used in this experiment was considered to be in a slightly hypercoagulable state because of the continuous contact with non-biological materials and calcium inflow from substitution fluid. Blood containing 7 or 8 mM of trisodium citrate and nafamostat mesilate could be effectively used to compare the lifetimes of hemofilters utilized under the same conditions. In this CHF model using porcine blood, the plugging of the hollow fibers occurred shortly after the plugging of the membrane pores. In conclusion, a CHF model using porcine blood can be established by adjusting the concentration of trisodium citrate added to the blood.

Entities:  

Keywords:  Continuous hemofiltration; Filter life; Fouling; Porcine blood; Trisodium citrate

Mesh:

Substances:

Year:  2018        PMID: 30039456     DOI: 10.1007/s10047-018-1060-3

Source DB:  PubMed          Journal:  J Artif Organs        ISSN: 1434-7229            Impact factor:   1.731


  6 in total

1.  Treatment of septic shock with continuous HDF using 2 PMMA hemofilters for enhanced intensity.

Authors:  Yosuke Matsumura; Shigeto Oda; Tomohito Sadahiro; Masataka Nakamura; Yo Hirayama; Eizo Watanabe; Ryuzo Abe; Taka-Aki Nakada; Yoshihisa Tateishi; Taku Oshima; Koichiro Shinozaki; Hiroyuki Hirasawa
Journal:  Int J Artif Organs       Date:  2012-01       Impact factor: 1.595

2.  Effects of increased surface coverage of polyvinylpyrrolidone over a polysulfone hemofilter membrane on permeability and cell adhesion during continuous hemofiltration.

Authors:  Kenichi Kokubo; Yoshitaka Kurihara; Hiroshi Tsukao; Naoko Maruyama; Kozue Kobayashi; Toshihiro Shinbo; Minoru Hirose; Hirosuke Kobayashi
Journal:  J Artif Organs       Date:  2015-04-03       Impact factor: 1.731

3.  Zero mortality of continuous veno-venous hemodiafiltration with PMMA hemofilter after pediatric cardiac surgery.

Authors:  Takashi Miyamoto; Akihiro Yoshimoto; Kazuhito Tatsu; Kentaro Ikeda; Yoichiro Ishii; Tomio Kobayashi
Journal:  Ann Thorac Cardiovasc Surg       Date:  2011       Impact factor: 1.520

4.  Continuous hemodiafiltration with a cytokine-adsorbing hemofilter for sepsis.

Authors:  Hiroyuki Hirasawa; Shigeto Oda; Masataka Nakamura; Eizo Watanabe; Hidetoshi Shiga; Kenichi Matsuda
Journal:  Blood Purif       Date:  2012-10-24       Impact factor: 2.614

5.  Measurement of ionized calcium in biological fluids.

Authors:  W G Robertson
Journal:  Clin Chim Acta       Date:  1969-04       Impact factor: 3.786

Review 6.  Continuous hemodiafiltration with cytokine-adsorbing hemofilter in the treatment of severe sepsis and septic shock.

Authors:  Hiroyuki Hirasawa; Shigeto Oda; Kenichi Matsuda
Journal:  Contrib Nephrol       Date:  2007       Impact factor: 1.580

  6 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.