Effects of increased surface coverage of polyvinylpyrrolidone over a polysulfone hemofilter membrane on permeability and cell adhesion during continuous hemofiltration.

Kenichi Kokubo1, Yoshitaka Kurihara, Hiroshi Tsukao, Naoko Maruyama, Kozue Kobayashi, Toshihiro Shinbo, Minoru Hirose, Hirosuke Kobayashi.   

Abstract

The purpose of the present study was to evaluate the adhesiveness of blood cells and the solute removal performance change of modified polysulfone membranes which have increased polyvinylpyrrolidone (PVP) coverage over their surface. Continuous hemofiltration (CHF) experiments for 24 h were carried out using an ex vivo hemofilter evaluation system to compare a modified polysulfone hemofilter (SHG) with the conventional polysulfone hemofilter (SH). The 25 and 50 % cutoff values of the sieving coefficient of dextran after CHF and the protein concentration in the filtrate was higher in SHG, indicating that less fouling occurred in the SHG membrane. Adhesion of blood cells after 24 h of CHF was significantly higher in the case of SH than in the case of SHG. Blood cell adhesion and membrane fouling were reduced with the use of a polysulfone membrane modified with increased PVP coverage over the surface.

Entities:  

Mesh:

Substances:

Year:  2015        PMID: 25837552     DOI: 10.1007/s10047-015-0826-0

Source DB:  PubMed          Journal:  J Artif Organs        ISSN: 1434-7229            Impact factor:   1.731


  16 in total

1.  Predilution versus postdilution continuous venovenous hemofiltration: no effect on filter life and azotemic control in critically ill patients on heparin.

Authors:  Shaikh A Nurmohamed; Borefore P Jallah; Marc G Vervloet; Albertus Beishuizen; A B Johan Groeneveld
Journal:  ASAIO J       Date:  2011 Jan-Feb       Impact factor: 2.872

Review 2.  Acute kidney injury: how can we facilitate recovery?

Authors:  Neil J Glassford; Rinaldo Bellomo
Journal:  Curr Opin Crit Care       Date:  2011-12       Impact factor: 3.687

3.  Pre-dilution vs. post-dilution during continuous veno-venous hemofiltration: impact on filter life and azotemic control.

Authors:  Shigehiko Uchino; Nigel Fealy; Ian Baldwin; Hiroshi Morimatsu; Rinaldo Bellomo
Journal:  Nephron Clin Pract       Date:  2003

4.  Regional cooling of the extracorporeal blood circuit: a novel anticoagulation approach for renal replacement therapy?

Authors:  Ales Krouzecky; Jiri Chvojka; Roman Sykora; Jaroslav Radej; Thomas Karvunidis; Ivan Novak; Jiri Ruzicka; Zuzana Petrankova; Jiri Benes; Lukas Bolek; Martin Matejovic
Journal:  Intensive Care Med       Date:  2008-09-18       Impact factor: 17.440

Review 5.  Choice of therapy and renal recovery.

Authors:  Shigehiko Uchino
Journal:  Crit Care Med       Date:  2008-04       Impact factor: 7.598

Review 6.  Circulation of the continuous artificial kidney: blood flow, pressures, clearances and the search for the best.

Authors:  R Bellomo; C Ronco
Journal:  Blood Purif       Date:  1997       Impact factor: 2.614

Review 7.  The coagulation system in the critically ill patient with acute renal failure and the effect of an extracorporeal circuit.

Authors:  A Davenport
Journal:  Am J Kidney Dis       Date:  1997-11       Impact factor: 8.860

8.  Surface topography and surface elemental composition analysis of Helixone, a new high-flux polysulfone dialysis membrane.

Authors:  S K Bowry; C Ronco
Journal:  Int J Artif Organs       Date:  2001-11       Impact factor: 1.595

Review 9.  Timing, dose and mode of dialysis in acute kidney injury.

Authors:  Zaccaria Ricci; Claudio Ronco
Journal:  Curr Opin Crit Care       Date:  2011-12       Impact factor: 3.687

10.  In vivo protein adsorption onto polymers: a transmission electron microscopic study.

Authors:  C Nojiri; K D Park; T Okano; S W Kim
Journal:  ASAIO Trans       Date:  1989 Jul-Sep
View more
  4 in total

1.  Continuous hemofiltration model using porcine blood for comparing filter life.

Authors:  Yoshitaka Kurihara; Shunichi Ueki; Kenichi Kokubo; Yuta Kobayashi; Tomoyo Ebine; Kaya Murakami; Yosuke Ushiroda; Naoko Maruyama; Hiroshi Tsukao; Kozue Kobayashi; Hirosuke Kobayashi
Journal:  J Artif Organs       Date:  2018-07-24       Impact factor: 1.731

Review 2.  Journal of Artificial Organs 2015: the year in review : Journal of Artificial Organs Editorial Committee.

Authors:  Y Sawa; K Matsuda; E Tatsumi; G Matsumiya; T Tsukiya; T Abe; K Fukunaga; A Kishida; K Kokubo; T Masuzawa; A Myoui; M Nishimura; T Nishimura; T Nishinaka; E Okamoto; S Tokunaga; T Tomo; Y Yagi; T Yamaoka
Journal:  J Artif Organs       Date:  2016-02-20       Impact factor: 1.731

3.  Asymmetric triacetate membrane keeps high water flux during ultrafiltration: in vitro study.

Authors:  Yoshihiro Tange; Shingo Takesawa; Shigenori Yoshitake
Journal:  J Artif Organs       Date:  2017-07-06       Impact factor: 1.731

4.  Replication of fouling in vitro in hollow fiber dialyzers by albumin immobilization.

Authors:  Takayoshi Kiguchi; Narumi Tomisawa; Akihiro C Yamashita
Journal:  J Artif Organs       Date:  2022-02-11       Impact factor: 1.731

  4 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.