Literature DB >> 30037578

In-vivo 3-Dimensional gait symmetry analysis in patients with bilateral total hip arthroplasty.

Paul Arauz1, Yun Peng1, John MacAuliffe1, Young-Min Kwon2.   

Abstract

Although three-dimensional (3D) asymmetry has been reported in unilateral THA patients during gait, it is not well understood whether asymmetric hip kinematics during gait persist in bilaterally operated THA patients. The purpose of this study was to compare the in vivo 3D kinematics and component placement between bilateral and unilateral THA patients during gait. Eight bilateral and thirty-three unilateral THA patients were evaluated for both hips during treadmill gait using a validated combination of 3D computer tomography-based modeling and dual fluoroscopic imaging system (DFIS). The in vivo 3D kinematics of the unilateral THA group was first assessed. The magnitudes of kinematics and component placement difference between implanted hips in the bilateral THA group and between the implanted and non-implanted hips in the unilateral THA group were compared. The study results showed asymmetric gait kinematics in the unilateral THA group. Although the magnitude of kinematics differences between sides for both the bilateral and unilateral THA groups did not change significantly for hip rotations (p > 0.05), the bilaterally operated THA group has significantly lower magnitude of hip gait translation difference. Significant reduction in the magnitude of the acetabular cup adduction, stem adduction, and combine hip anteversion and adduction difference was observed in the bilateral THA group (p < 0.05). Our findings demonstrated that despite significant improvements of component placement and reduced magnitude of hip gait translation difference between implanted hips in the bilateral THA group, asymmetric hip kinematic rotations persisted in patients with bilateral THA during gait.
Copyright © 2018 Elsevier Ltd. All rights reserved.

Entities:  

Keywords:  Asymmetry; Bilateral total hip arthroplasty; Component positioning; Gait; Kinematics

Mesh:

Year:  2018        PMID: 30037578     DOI: 10.1016/j.jbiomech.2018.07.013

Source DB:  PubMed          Journal:  J Biomech        ISSN: 0021-9290            Impact factor:   2.712


  7 in total

1.  Customized implants for acetabular Paprosky III defects may be positioned with high accuracy in revision hip arthroplasty.

Authors:  Markus Weber; Lena Witzmann; Jan Wieding; Joachim Grifka; Tobias Renkawitz; Benjamin Craiovan
Journal:  Int Orthop       Date:  2018-10-10       Impact factor: 3.075

2.  Spine and lower body symmetry during treadmill walking in healthy individuals-In-vivo 3-dimensional kinematic analysis.

Authors:  Paul Gonzalo Arauz; Maria-Gabriela Garcia; Patricio Chiriboga; Sebastian Taco-Vasquez; Diego Klaic; Emilia Verdesoto; Bernard Martin
Journal:  PLoS One       Date:  2022-10-06       Impact factor: 3.752

3.  Effects of a corrective heel lift with an orthopaedic walking boot on joint mechanics and symmetry during gait.

Authors:  A Cecilia Severin; R Pearson Gean; Sally G Barnes; Robin Queen; Robert J Butler; Robert Martin; C Lowry Barnes; Erin M Mannen
Journal:  Gait Posture       Date:  2019-07-26       Impact factor: 2.840

4.  Bi-cruciate retaining total knee arthroplasty: a systematic literature review of clinical outcomes.

Authors:  Christoph Kolja Boese; Stephen Ebohon; Christian Ries; Diarmuid De Faoite
Journal:  Arch Orthop Trauma Surg       Date:  2020-10-13       Impact factor: 3.067

5.  Towards an Inertial Sensor-Based Wearable Feedback System for Patients after Total Hip Arthroplasty: Validity and Applicability for Gait Classification with Gait Kinematics-Based Features.

Authors:  Wolfgang Teufl; Bertram Taetz; Markus Miezal; Michael Lorenz; Juliane Pietschmann; Thomas Jöllenbeck; Michael Fröhlich; Gabriele Bleser
Journal:  Sensors (Basel)       Date:  2019-11-16       Impact factor: 3.576

6.  Does treadmill workstation use affect user's kinematic gait symmetry?

Authors:  Paul Gonzalo Arauz; María-Gabriela García; Mauricio Velez; Cesar León; Francisco Velez; Bernard Martin
Journal:  PLoS One       Date:  2021-12-14       Impact factor: 3.240

Review 7.  New technologies applied to canine limb prostheses: A review.

Authors:  Paul G Arauz; Patricio Chiriboga; María-Gabriela García; Imin Kao; Eduardo A Díaz
Journal:  Vet World       Date:  2021-10-28
  7 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.