The reliability of postural control method in athletes with and without ACL reconstruction: a transitional task.

Forough Ferdowsi1, Azadeh Shadmehr1, Seied Mohsen Mir1, Golamreza Olyaei1, Saeed Talebian1, Sohrab Keihani2.   

Abstract

[Purpose] To evaluate the intra- and inter-session reliability of dynamic postural control in ACL reconstruction and matched control athletes.
[Subjects and Methods] By using force plate, the postural controls of both groups (20 ACLR and 20 healthy matched controls) were assessed during the transitional task from DLS to SLS. The outcome variables included COP displacement and area and the mean velocity of COP.
[Results] The balance measures had moderate to high correlation for area (ICC=0.64-0.73) and rang of fore-aft (Rfa) (ICC=0.66-0.80) in the ACLR group and Rfa (ICC=0.70-0.86) in the healthy group. High to very high reliability was seen for rang of sideway (Rsw) (ICC=0.76-0.96) and mean velocity (Mv) (ICC=0.81-0.98) in ACLR and area (ICC=0.70-0.98) and Rsw (ICC=0.84-0.98) and Mv (ICC=0.89-0.97) in the healthy group.
[Conclusion] Force plate measures of postural control demonstrated moderate to very high reliability in athletes with and without ACLR during the transitional task. The results of the recent study showed that the assessment of transitional task postural control in athletes with ACLR may reliably be incorporated in the evaluation of the physical function.

Entities:  

Keywords:  Anterior cruciate ligament reconstruction; Force plate; Transitional task

Year:  2018        PMID: 30034092      PMCID: PMC6047968          DOI: 10.1589/jpts.30.896

Source DB:  PubMed          Journal:  J Phys Ther Sci        ISSN: 0915-5287


INTRODUCTION

The anterior cruciate ligament (ACL) is one of the major ligaments of knee, riches mechanoreceptors1). According to the sensory role of ACL, it plays a key role in the postural control of lower limbs2). ACL injuries are the most common knee ligament injury in sports activities, among which 70% are due to non-contact processes such as jump-landing, pivoting, and cutting3). ACL reconstruction (ACLR) is performed to restore the mechanical and functional stability of the knee1). The ability to maintain postural control requires intact inputs from visual, vestibular, and somatosensory systems4). Postural control impairments are related to a (re-)injury risk in healthy and lower extremity musculoskeletal pathological subjects5). The recent literature supports a trend toward impaired postural control in ACLR subjects. So, postural control deficits exist in the operated and non-operated leg following ACLR surgery6). Previous studies have shown that postural control differences in the static single-legged standing position (SLS) in ACLR individuals are controversial6, 7). Moving toward the opposite leg before finishing the single leg stance phase is essential. The characteristics of this contralateral weight shift movement and the ability to overcome the internal perturbation created by the transitional movement from the double leg stance (DLS) to single limb largely influence postural control sequences when standing on one leg5). Recently, the literature shows that the weight shift transitional task from DLS to SLS is different between healthy and pathological subjects1, 8, 9), while its effectiveness on the characteristics of postural control in the SLS phase has not been much paid attention to in the previous studies. In daily and sporting activities, the subject needs to switch from DLS to SLS and vice versa repeatedly4). Therefore, it seems necessary to use a transitional task from DLS to SLS with the aim of evaluating functional ability before, during, and after voluntary movements in healthy and ACLR subjects6). To the authors’ knowledge, there is no study that has evaluated the reliability of this method in ACLR and healthy athletes. Since the reliability of this method may have important clinical implications for evaluating postural control and rehabilitation in ACLR subjects, this study aims to assess the intra- and inter-session test retest reliability of balance due to the transitional task from DLS to SLS in athletes with and without ACLR.

SUBJECTS AND METHODS

As many as 40 male soccer players (20 healthy and 20 ACLR athletes) voluntarily participated in the study. The athletes in the ACLR group had undergone reconstruction surgery by single orthopedic surgeons (who was referred samples from the University Hospital Orthopedic Center) in a similar fashion (hamstring tendon graft) and the control subjects were the patients’ teammates. The ACLR group included athletes with a history of unilateral ACLR, at least six months before testing who had returned to their sports activities. Both groups were matched to their teammates according to the demographic characteristic (Table1). The ACLR and healthy groups were not different in terms of the physical activity level (all of them were scored 9 according to Tegner’s questionnaire). The athletes in the two groups were excluded if they reported neurological and orthopedic problems in low back, either of the lower limbs (except meniscal injuries in the ACLR group), and vestibular and visual dysfunctions. After the athletes had been briefed on all testing procedures, they were asked to read and sign an informed consent form that was approved by Ethics Committee of Tehran University of Medical Science (Ethics approval number: 9323341999).
Table 1.

Demographic characteristic of the subjects in the experimental group

VariablesGroups

ACLR (n=20)Healthy (n=20)


MeanSDMeanSD
Age (years)27.23.7526.23.18
Height (cm)185.04.69184.04.12
Weight (kg)84.85.4782.54.32
Each subject was asked to perform the weight shift task from DLD to SLS, by the same examiner. Each measurement was repeated three times in the test session, and all the measurements were repeated two to seven days later in the retest session. The average scores of each session were used for analysis. The participants were allowed to rest for one minute between each test to prevent fatigue. The test order was randomized to control for sequence effects. Only the reconstructed limbs of the patients and the matched limbs of the control group were tested. In this study, the testing procedure was based on a method design by Dingenen et al5). The participants performed three standing trials for each testing procedure while keeping their eyes open at a fixed point localized on a facing wall. Each testing procedure started with a 25 second DLS where the athletes were asked to stand barefoot on the center of a single force platform and kept the arms along the body (90 × 90 cm, Bertec Columbus, OH, USA). Next, the athletes were instructed to do transition to SLS on their legs while they maintained 60° hip flexion for 30 seconds on their tested leg. Finally, the athletes’ transition to DLS for 5 seconds on a line lying on the center of the force plate ensure that they were localized at the correct position. It is necessary to mention that the first 5 seconds of SLS phase was considered as the loading phase, while the last 5 seconds of the total testing procedure was regarded as the unloading phase. All the athletes were instructed to perform the transition task from DLS to SLS to DLS with preferred speed. The 500 Hz frequency and low-pass filter with a cut off frequency of 10 Hz were measured by the following variables: COP displacement for range sideways (Rsw) and range fore-aft (Rfa), area, and the mean velocity (Mv) of COP10). The sample size was estimated based on the pilot study and 20 subjects were considered in each group: A significant level of 0.05 and a power of 0.95 was assumed. For statical analysis, the SPSS program (version 17) was used. To explore the presence of any systematic bias, paired t-tests were used to compare the differences between COP variables in the test and retest sessions11). Three trials of each condition in the test-retest session were used to calculate the intra-session reliability of the COP variables. In the two sessions (test and retest session), an average of three trials for each condition were used to compute the test retest reliability. We calculated the relative intra- and inter-session reliabilities using a two-way random model of intraclass correlation coefficient (ICC2,3)12). Munro’s classification for reliability coefficients was utilized to define the extent of reliability. In this classification, the criteria range for reliability is as the following: 0.26 and 0.49 (low correlation), 0.5 and 0.69 (moderate correlation), 0.7 and 0.89 (high correlation), and 0.9 and 1.00 (very high correlation)13). To assess absolute reliability, the standard error of measurement (SEM) was computed to estimate the amount of error associated with the measurement. The minimal detectable change (MDC) was determined as 95% CI of SEM for balance variables (± 1.96 SEM) used to evaluate the change that could be considered significant between the two times of measurement11, 14).

RESULTS

The mean and standard deviation (SD) of force plate measurements are represented in Table 2 for all testing conditions. There was no significant difference between the test and retest mean scores for all balance parameters (n.s) that demonstrate no systematic bias.
Table 2.

Descriptive data for test-retest stability indexes made under different conditions of balance task in a sample of individuals with ACLR (n=20) and healthy (n=20) athletes

GroupTaskVariablesTest session


Stability indexTestRetest


MeanSDMeanSD
ACLRDLSArea 1.421.221.050.91
Rfa2.110.791.990.57
RSW1.120.411.110.43
Mv0.060.010.060.01

IntegrationArea 74.9333.6773.2231.72
Rfa4.071.204.141.14
RSW20.053.1320.313.47
Mv0.600.100.620.09

SLSArea 62.0514.1960.0112.22
Rfa3.810.873.670.66
RSW3.070.493.030.49
Mv0.190.020.190.02

ReintegrationArea 89.1134.6687.7934.46
Rfa4.000.733.670.66
RSW19.944.1520.104.28
Mv0.720.140.720.14

HealthyDLSArea 1.460.971.140.79
Rfa2.080.432.020.52
RSW1.270.521.160.49
Mv0.060.010.050.01

IntegrationArea 71.2525.5581.1240.02
Rfa4.041.153.630.79
RSW19.693.2819.642.15
Mv0.590.070.580.06

SLSArea 52.3914.6555.5714.33
Rfa3.270.683.470.89
RSW2.900.392.850.38
Mv0.180.030.180.02

ReintegrationArea 68.9336.7081.1240.02
Rfa4.281.093.861.23
RSW19.413.9419.863.61
Mv0.730.140.740.13

Values are mean ± Standard Deviation (SD). p refers to p values of paired t test on test–retest difference. n.s: non-significant. Unit of Area: cm2, Rfa: cm, Rsw: cm and Mv: cm/sec.

Values are mean ± Standard Deviation (SD). p refers to p values of paired t test on test–retest difference. n.s: non-significant. Unit of Area: cm2, Rfa: cm, Rsw: cm and Mv: cm/sec. The intra-session reliability and inter-session reliability of the balance measures are shown in Table 3. In general, the intra-session reliability of the balance measure show moderate to very high correlation for the test and retest sessions in both groups. The intra-session ICCs of the test session ranged from 0.64 to 0.91 in the ACLR group and 0.67 to 0.94 in the healthy group. Moreover, the ICCs of the retest session ranged from 0.68 to 0.96 (ACLR) and 0.73 to 0.92 (Healthy).
Table 3.

Intra- and intersession reliability of the stability indexes made under different conditions of balance test in a sample of individuals with ACLR and healthy athletes and healthy athletes

GroupTaskVariablesIntra sessionInter session



Stability indexTest ICCRetest ICCICCSEMMMDC
ACLRDLSArea 0.820.910.730.5740.94
Rfa 0.900.690.800.2814.98
Rsw0.690.770.760.8519.36
Mv0.700.890.880.0113.53

IntegrationArea 0.910.780.6425.6027.32
Rfa 0.750.760.660.7016.05
Rsw0.900.940.881.448.75
Mv0.730.890.810.047.47

SLSArea 0.700.680.689.2315.03
Rfa 0.640.730.670.5614.67
Rsw0.650.690.960.098.40
Mv0.810.830.980.0110.19

ReintegrationArea 0.920.660.6426.6230.42
Rfa 0.710.830.720.7617.78
Rsw0.900.960.832.0111.94
Mv0.900.940.860.0711.77

HealthyDLSArea 0.750.910.700.7051.53
Rfa 0.670.730.700.4720.89
Rsw0.890.900.840.2223.60
Mv0.780.920.890.0117.17

IntegrationArea 0.720.820.7520.5727.37
Rfa 0.740.840.860.5717.70
Rsw0.910.850.891.4310.16
Mv0.800.900.890.0410.08

SLSArea 0.880.800.708.9013.45
Rfa 0.760.910.700.5812.86
Rsw0.760.830.880.229.96
Mv0.820.860.930.018.90

ReintegrationArea 0.940.810.982.4324.22
Rfa 0.700.770.700.4711.11
Rsw0.870.920.980.7713.06
Mv0.890.900.970.0112.29

ICC: intraclass correlation coefficient; SEM: standard error of measurement; MMDC: minimal metrically detectable change.

ICC: intraclass correlation coefficient; SEM: standard error of measurement; MMDC: minimal metrically detectable change. The inter-session reliability of the balance measure showed moderate to very high correlation in both ACLR (0.67 to 0.94) and healthy (0.73 to 0.92) groups. Besides, the SEM and MDC of the balance measures are displayed in Table 3.

DISCUSSION

The present study examined the inter-session and intra-session reliability of the force plate in subjects with and without ACLR during the weight shift transitional task from DLS to SLS. According to the author’s findings, there has been no study until now on the reliability of force plate measurements in subjects with and without ACLR using the transitional task from DLS to SLS. Significant findings of the present study were that dynamic balance measures are reliable outcomes in ACLR and healthy athletes. The results of present study demonstrate moderate to very high reliability for balance measures in all test conditions. This indicates that the possibility of the Type 2 error would be limited because of small measurement errors in comparison with the variability between subjects15). The highest intra-session reliability for the test session was an area in the reintegration phase of the transitional task from DLS to SLS in ACLRs and healthy groups. And, the highest reliability for the retest session was Rsw in the reintegration phase of the test position in both groups. The mean velocity parameters in SLS in ACLR groups as well as the area and Rsw parameters in the reintegration phase in the healthy group demonstrated the highest intra-session reliability. Outcome stability is one of the fundamental factors related to variations in the test-retest reliability studies. Motor control system is mainly effective on the balance control measurements. Thus, learning is effective on the stability measurement, which reduces the outcome following multiple measurements16). The learning effect in the current study was minimal so that the balance measures showed an admissible reliability. Another possible reason may be related to the nature of this task. A static single legged phase has been used in the previous studies7, 17), while an internal perturbation effect was applied in this study due to the transition from DLS to SLS. This transitional task was difficult to perform in comparisons with the static SLS. Moreover it was similar to what was experienced in daily living and might have thus caused differences in the postural control responses. Although there are no studies assessing reliabilities of these parameters in the ACLR and healthy athletes and the mentioned transitional task from DLS to SLS, the results of the present study showed high levels of reliability (ICC>0.8) for mean velocity. In this case, it may be comparable to the study of Mohammadi et al7). Mohammadi et al.7) examined the subjects eight months after surgery, but the test time in our study was 16 months after reconstructed surgery. On the other hand, the interval repetition between the test and retest sessions in the present study was two to seven days while the interval between the two test sessions was seven to eight days in Mohammadi’s study. During the transitional task from DLS to SLS, the subject is in a state of internal perturbation, which influences the SLS phase. The present study shows a similar result by studying such perturbation15, 16, 18). The absolute reliability of mean velocity in both groups was the lowest score in all test conditions. The smaller SEM provides an estimate of the smaller error between the test and retest sessions11). The Rsw in both groups in the SLS position had the lowest MDC among all test conditions. Since the MDC of the stability index provides information about the amount of the measurement error, lesser scores imply a sensitive amount. In the current study, the dynamic balance measures were found to produce satisfactory reliabilities in the ACLR and healthy athletes. Thus it may be clinically considerable to include these measures in the protocols examining the effects of surgical and rehabilitative interventions in athletes following an ACL reconstruction to restore their functional stabilities. Furthermore, the results may contribute to the description of the postural control deficits discovered in athletes especially during the transitional task from DLS to SLS. Also, transitional task trainer may benefit the training to improve their athletes’ postural control performances. One of the limitations of this study was the possibility of generalizing the results only to the mentioned tested populations, but not to any other populations or transitional tasks. Therefore, further research is suggested to be performed on the reliabilities of other force plate parameters among populations with varied histories of activity levels and injuries.

Funding

This research has been supported by Tehran University of Medical Sciences & Health Services grant 96-01-32-34315 as part of a PhD thesis.

Conflict of interest

None.
  15 in total

1.  Static and dynamic postural control in competitive athletes after anterior cruciate ligament reconstruction and controls.

Authors:  Farshid Mohammadi; Mahyar Salavati; Behnam Akhbari; Masood Mazaheri; Mojdeh Khorrami; Hossein Negahban
Journal:  Knee Surg Sports Traumatol Arthrosc       Date:  2011-11-29       Impact factor: 4.342

2.  Sway activity and muscle recruitment order during transition from double to single-leg stance in subjects with chronic ankle instability.

Authors:  Oron Levin; Adriaan Van Nevel; Colin Malone; Sara Van Deun; Jacques Duysens; Filip Staes
Journal:  Gait Posture       Date:  2012-06-20       Impact factor: 2.840

3.  Reliability of recurrence quantification analysis measures of the center of pressure during standing in individuals with musculoskeletal disorders.

Authors:  Masood Mazaheri; Hossein Negahban; Mahyar Salavati; Mohammad Ali Sanjari; Mohamad Parnianpour
Journal:  Med Eng Phys       Date:  2010-05-31       Impact factor: 2.242

4.  Intrasession reliability of the "center of pressure minus center of mass" variable of postural control in the healthy elderly.

Authors:  H Corriveau; R Hébert; F Prince; M Raîche
Journal:  Arch Phys Med Rehabil       Date:  2000-01       Impact factor: 3.966

5.  The assessment of body sway and the choice of the stability parameter(s).

Authors:  J A Raymakers; M M Samson; H J J Verhaar
Journal:  Gait Posture       Date:  2005-01       Impact factor: 2.840

6.  Reliability of posturographic measurements in the assessment of impaired sensorimotor function in chronic low back pain.

Authors:  C Leitner; P Mair; B Paul; F Wick; C Mittermaier; T Sycha; G Ebenbichler
Journal:  J Electromyogr Kinesiol       Date:  2007-11-26       Impact factor: 2.368

Review 7.  Cortical control of postural responses.

Authors:  J V Jacobs; F B Horak
Journal:  J Neural Transm (Vienna)       Date:  2007-03-29       Impact factor: 3.575

Review 8.  Statistical methods for assessing measurement error (reliability) in variables relevant to sports medicine.

Authors:  G Atkinson; A M Nevill
Journal:  Sports Med       Date:  1998-10       Impact factor: 11.136

9.  Altered muscle activation following hamstring injuries.

Authors:  Gisela Sole; Stephan Milosavljevic; Helen Nicholson; S John Sullivan
Journal:  Br J Sports Med       Date:  2011-03-10       Impact factor: 13.800

10.  Reliability of dynamic balance simultaneously with cognitive performance in patients with ACL deficiency and after ACL reconstructions and in healthy controls.

Authors:  Behnam Akhbari; Mahyar Salavati; Jalal Ahadi; Forough Ferdowsi; Alireza Sarmadi; Sohrab Keyhani; Farshid Mohammadi
Journal:  Knee Surg Sports Traumatol Arthrosc       Date:  2014-06-12       Impact factor: 4.342

View more
  1 in total

1.  Reliability of Center of Pressure measures of Postural Stability in Anterior Cruciate Ligament Reconstructed Athletes: Effect of Vibration and Cognitive Load.

Authors:  Shahrzad Mohammadi-Rad; Mohammad Ali Mohseni Bandpei; Mahyar Salavati; Saeed Talebian; Sohrab Keyhani; Sanaz Shanbehzadeh
Journal:  Arch Bone Jt Surg       Date:  2022-02
  1 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.