On the total system error of a robotic radiosurgery system: phantom measurements, clinical evaluation and long-term analysis.

E Pantelis1, A Moutsatsos, C Antypas, E Zoros, P Pantelakos, L Lekas, P Romanelli, K Zourari, C J Hourdakis.   

Abstract

The total system error (TSE) of a CyberKnife® system was measured using two phantom-based methods and one patient-based method. The standard radiochromic film (RCF) end-to-end (E2E) test using an anthropomorphic head and neck phantom and isocentric treatment delivery was used with the 6Dskull, Fiducial and Xsight® spine (XST) tracking methods. More than 200 RCF-based E2E results covering the period from installation in 2006 until 2017 were analyzed with respect to tracking method, system hardware and software versions, secondary collimation system, and years since installation. An independent polymer gel E2E method was also applied, involving a 3D printed head phantom and multiple spherical target volumes widely distributed within the brain. Finally, the TSE was assessed by comparing the delineated target in the planning computed tomography images of a patient treated for a thalamic functional target with the radiation-induced lesion defined on the six-month follow-up magnetic resonance (MR) images. Statistical analysis of the RCF-based TSE results showed mean  ±  standard deviation values of 0.40  ±  0.18 mm, 0.40  ±  0.19 mm, and 0.55  ±  0.20 mm for the 6Dskull, Fiducial, and XST tracking methods, respectively. Polymer gel TSE values smaller than 0.66 mm were found for seven targets distributed within the brain, showing that the targeting accuracy of the system is sustained even for targets situated up to 80 mm away from the center of the skull. An average clinical TSE value of 0.87  ±  0.25 mm was also measured using the FSE T2 and FLAIR post-treatment MR image data. Analysis of the long-term RCF-based E2E tests showed no changes of TSE over time. This study is the first to report long-term (>10 years) analysis of TSE, TSE measurement for targets positioned at large distances from the virtual machine isocenter, or a clinical assessment of TSE for the CyberKnife system. All of these measurements demonstrate TSE consistently  <  1 mm.

Entities:  

Mesh:

Year:  2018        PMID: 30033940     DOI: 10.1088/1361-6560/aad516

Source DB:  PubMed          Journal:  Phys Med Biol        ISSN: 0031-9155            Impact factor:   3.609


  6 in total

1.  The impact of target positioning error and tumor size on radiobiological parameters in robotic stereotactic radiosurgery for metastatic brain tumors.

Authors:  Takeshi Takizawa; Satoshi Tanabe; Hisashi Nakano; Satoru Utsunomiya; Madoka Sakai; Katsuya Maruyama; Shigekazu Takeuchi; Toshimichi Nakano; Atsushi Ohta; Motoki Kaidu; Hiroyuki Ishikawa; Kiyoshi Onda
Journal:  Radiol Phys Technol       Date:  2022-03-07

2.  Robustness of single-isocenter multiple-metastasis stereotactic radiosurgery end-to-end testing across institutions.

Authors:  Daniel Saenz; Niko Papanikolaou; Emmanouil Zoros; Evangelos Pappas; Michael Reiner; Lip Teck Chew; Hooi Yin Lim; Sam Hancock; Alex Nebelsky; Christopher Njeh; Georgios Anagnostopoulos
Journal:  J Radiosurg SBRT       Date:  2021

3.  CyberKnife for Recurrent Malignant Gliomas: A Systematic Review and Meta-Analysis.

Authors:  Lucio De Maria; Lodovico Terzi di Bergamo; Alfredo Conti; Kazuhiko Hayashi; Valentina Pinzi; Taro Murai; Rachelle Lanciano; Sigita Burneikiene; Michela Buglione di Monale; Stefano Maria Magrini; Marco Maria Fontanella
Journal:  Front Oncol       Date:  2021-03-29       Impact factor: 6.244

4.  Comparative study of SRS end-to-end QA processes of a diode array device and an anthropomorphic phantom loaded with GafChromic XD film.

Authors:  Seng Boh Lim; LiCheng Kuo; Tianfang Li; Xiang Li; Ase M Ballangrud; Michael Lovelock; Maria F Chan
Journal:  J Appl Clin Med Phys       Date:  2022-08-10       Impact factor: 2.243

5.  Validation of PTV margin for Gamma Knife Icon frameless treatment using a PseudoPatient® Prime anthropomorphic phantom.

Authors:  Eun Young Han; Parmeswaran Diagaradjane; Dershan Luo; Yao Ding; Georgios Kalaitzakis; Emmanouil Zoros; Kyveli Zourari; Themistoklis Boursianis; Evangelos Pappas; Zhifei Wen; Jihong Wang; Tina Marie Briere
Journal:  J Appl Clin Med Phys       Date:  2020-08-12       Impact factor: 2.102

6.  Implementing and evaluating a high-resolution diode array for patient-specific quality assurance of robotic brain stereotactic radiosurgery/radiotherapy.

Authors:  Qianyi Xu; Kiet Huynh; Wei Nie; Mark S Rose; Ashish K Chawla; Kevin S Choe; Samir Kanani; Gregory J Kubicek; Jiajin Fan
Journal:  J Appl Clin Med Phys       Date:  2022-03-12       Impact factor: 2.243

  6 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.