Literature DB >> 30030978

Magnetic Resonance Imaging of the Globe-Tendon Interface for Extraocular Muscles: Is There an "Arc of Contact"?

Robert A Clark1, Joseph L Demer2.   

Abstract

PURPOSE: To determine if the "arc of contact" is an accurate approximation of the globe-tendon interface for the biomechanical modeling of extraocular muscle (EOM) force transfer onto the globe.
METHODS: At a single academic institution, 18 normal and 14 strabismic subjects were prospectively recruited for surface-coil enhanced magnetic resonance imaging at 312- or 390-μm resolution in axial planes for horizontal EOMs (23 subjects, 26 orbits) and sagittal planes for vertical EOMs (13 subjects, 22 orbits) during large ipsiversive ductions. The measured angle at insertion and the predicted angle assuming an "arc of contact" were compared using paired t tests.
RESULTS: For normal EOMs, the measured angle at insertion was significantly greater than predicted assuming an "arc of contact" for the medial rectus (MR) (5.0 ± 4.8 degrees vs 0.0 ± 0.0 degrees, P = .03), lateral rectus (LR) (4.9 ± 3.0 degrees vs 0.0 ± 0.0 degrees, P = .02), inferior rectus (7.4 ± 4.8 degrees vs 1.2 ± 2.6 degrees, P = .00003), and superior rectus (0.6 ± 1.1 degrees vs 0.0 ± 0.0 degrees, P = .04). In strabismic subjects, the measured angle was significantly greater for the MR in abducens palsy (9.9 ± 4.3 degrees vs 0.5 ± 0.7 degrees, P = .0007) and after MR resection (9.0 ± 6.9 degrees vs 1.2 ± 2.4 degrees, P = .02), but not after LR recession (2.9 vs 0.0 degrees). Single subjects had comparable angles after MR recession, but markedly different angles after MR and LR posterior fixation.
CONCLUSIONS: Contrary to the "arc of contact" biomechanical model, normal and postsurgical EOMs are significantly non-tangent to the globe at their scleral insertions. The "arc of contact" should be replaced in biomechanical modeling by the experimentally measured angles at tendon insertions. NOTE: Publication of this article is sponsored by the American Ophthalmological Society.
Copyright © 2018 Elsevier Inc. All rights reserved.

Entities:  

Mesh:

Year:  2018        PMID: 30030978      PMCID: PMC6420818          DOI: 10.1016/j.ajo.2018.07.002

Source DB:  PubMed          Journal:  Am J Ophthalmol        ISSN: 0002-9394            Impact factor:   5.258


  51 in total

Review 1.  Slipped and lost extraocular muscles.

Authors:  T D Lenart; S R Lambert
Journal:  Ophthalmol Clin North Am       Date:  2001-09

2.  Functional morphometry demonstrates extraocular muscle compartmental contraction during vertical gaze changes.

Authors:  Robert A Clark; Joseph L Demer
Journal:  J Neurophysiol       Date:  2015-11-04       Impact factor: 2.714

3.  Magnetic resonance imaging of differential compartmental function of horizontal rectus extraocular muscles during conjugate and converged ocular adduction.

Authors:  Joseph L Demer; Robert A Clark
Journal:  J Neurophysiol       Date:  2014-05-21       Impact factor: 2.714

4.  The influence of pulleys on the quantitative characteristics of medial rectus muscle recessions: the torque vector model.

Authors:  Aaron M Miller; James L Mims
Journal:  J AAPOS       Date:  2006-08       Impact factor: 1.220

5.  Surgical correction of an inferiorly displaced lateral rectus with equatorial myopexy.

Authors:  Tiana Y Clark; Robert A Clark
Journal:  J AAPOS       Date:  2016-09-22       Impact factor: 1.220

6.  Posterior fixation suture operation (fadenoperation).

Authors:  E P Shuckett; D A Hiles; A W Biglan; D E Evans
Journal:  Ophthalmic Surg       Date:  1981-08

7.  Heavy eye syndrome versus sagging eye syndrome in high myopia.

Authors:  Roland Joseph D Tan; Joseph L Demer
Journal:  J AAPOS       Date:  2015-12       Impact factor: 1.220

8.  Magnetic resonance imaging of human extraocular muscles during static ocular counter-rolling.

Authors:  Joseph L Demer; Robert A Clark
Journal:  J Neurophysiol       Date:  2005-07-20       Impact factor: 2.714

9.  A 12-year, prospective study of extraocular muscle imaging in complex strabismus.

Authors:  Joseph L Demer; Robert A Clark; Reika Kono; Weldon Wright; Federico Velez; Arthur L Rosenbaum
Journal:  J AAPOS       Date:  2002-12       Impact factor: 1.220

10.  How far can a medial rectus safely be recessed?

Authors:  B J Kushner; M R Fisher; N J Lucchese; G V Morton
Journal:  J Pediatr Ophthalmol Strabismus       Date:  1994 May-Jun       Impact factor: 1.402

View more
  3 in total

Review 1.  MR-Eye: High-Resolution Microscopy Coil MRI for the Assessment of the Orbit and Periorbital Structures, Part 1: Technique and Anatomy.

Authors:  N W Dobbs; M J Budak; R D White; I A Zealley
Journal:  AJNR Am J Neuroradiol       Date:  2020-04-02       Impact factor: 3.825

2.  The Effect of Axial Length on Extraocular Muscle Leverage.

Authors:  Robert A Clark; Joseph L Demer
Journal:  Am J Ophthalmol       Date:  2020-04-02       Impact factor: 5.258

Review 3.  MR-Eye: High-Resolution Microscopy Coil MRI for the Assessment of the Orbit and Periorbital Structures, Part 2: Clinical Applications.

Authors:  N W Dobbs; M J Budak; R D White; I A Zealley
Journal:  AJNR Am J Neuroradiol       Date:  2021-03-18       Impact factor: 4.966

  3 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.