PURPOSE: In the clinic, computed tomography (CT) has evolved into an essential modality for diagnostic imaging by multidetector row CT (MDCT) and image guided intervention by cone beam CT (CBCT). Recognizing the increasing importance of axial MDCT/CBCT in clinical and preclinical applications, and the existence of CB artifacts in MDCT/CBCT images, we provide a review of CB artifacts' root causes, rendering mechanisms and morphology, and possible solutions for elimination and/or reduction of the artifacts.
METHODS: By examining the null space in Radon and Fourier domain, the root cause of CB artifacts (i.e., data insufficiency) in axial MDCT/CBCT is analytically investigated, followed by a review of the data sufficiency conditions and the "circle +" source trajectories. The rendering mechanisms and morphology of CB artifacts in axial MDCT/CBCT and their special cases (e.g., half/short scan and full scan with latitudinally displaced detector) are then analyzed, followed by a survey of the potential solutions to suppress the artifacts. The phenomenon of imaged zone indention and its variation over FBP, BPF/DBPF, two-pass and iterative CB reconstruction algorithms and/or schemes are discussed in detail.
RESULTS: An interdomain examination of the null space provides an insightful understanding of the root cause of CB artifacts in axial MDCT/CBCT. The decomposition of CB artifacts rendering mechanisms facilitates understanding of the artifacts' behavior under different conditions and the potential solutions to suppress them. An inspection of the imaged zone intention phenomenon provides guidance on the design and implementation of CB image reconstruction algorithms and schemes for CB artifacts suppression in axial MDCT/CBCT.
CONCLUSIONS: With increasing importance of axial MDCT/CBCT in clinical and preclinical applications, this review article can update the community with in-depth information and clarification on the latest progress in dealing with CB artifacts and thus increase clinical/preclinical confidence.
© 2018 American Association of Physicists in Medicine.

Entities:  

Keywords:  zzm321990CBCTzzm321990; zzm321990CTzzm321990; zzm321990MDCTzzm321990; zzm321990MSCTzzm321990; CB artifact; axial CT data acquisition; axial CT scan; cone beam CT; cone beam artifacts; multidetector CT; multislice CT

Year:  2018        PMID: 30019342     DOI: 10.1002/mp.13095

Source DB:  PubMed          Journal:  Med Phys        ISSN: 0094-2405            Impact factor:   4.071


  5 in total

1.  Comparison of radiographical characteristics and diagnostic accuracy of intraosseous jaw lesions on panoramic radiographs and CBCT.

Authors:  Wei-Yu Mao; Jie Lei; Li Zhen Lim; Yan Gao; Donald A Tyndall; Kaiyuan Fu
Journal:  Dentomaxillofac Radiol       Date:  2020-09-17       Impact factor: 2.419

2.  Metal artifacts in intraoperative O-arm CBCT scans.

Authors:  Juha I Peltonen; Touko Kaasalainen; Mika Kortesniemi
Journal:  BMC Med Imaging       Date:  2021-01-06       Impact factor: 1.930

3.  Intelligent Algorithm-Based Multislice Spiral Computed Tomography to Diagnose Coronary Heart Disease.

Authors:  Shaowen Tan; Zili Xu
Journal:  Comput Math Methods Med       Date:  2022-01-13       Impact factor: 2.238

4.  Feasibility of dual-energy CBCT by spectral filtration of a dual-focus CNT x-ray source.

Authors:  Boyuan Li; Derrek Spronk; Yueting Luo; Connor Puett; Christina R Inscoe; Donald A Tyndall; Yueh Z Lee; Jianping Lu; Otto Zhou
Journal:  PLoS One       Date:  2022-02-03       Impact factor: 3.240

5.  Implementation and experimental evaluation of Mega-voltage fan-beam CT using a linear accelerator.

Authors:  Hao Gong; Shengzhen Tao; Justin D Gagneur; Wei Liu; Jiajian Shen; Cynthia H McCollough; Yanle Hu; Shuai Leng
Journal:  Radiat Oncol       Date:  2021-07-28       Impact factor: 3.481

  5 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.