OBJECTIVES: To quantify intravoxel incoherent motion (IVIM)-DWI and dynamic contrast-enhanced (DCE)-MRI parameters in normal and abnormal ileal segments in Crohn's disease (CD) patients and to assess the association of these parameters with clinical and MRI-based measurements of CD activity.
METHODS: In this prospective study, 27 CD patients (M/F 18/9, mean age 42 years) underwent MR enterography, including IVIM-DWI and DCE-MRI. IVIM-DWI and DCE-MRI parameters were quantified in normal and abnormal small bowel segments, the latter identified by the presence of inflammatory changes. MRI parameter differences between normal and abnormal bowel were tested using Wilcoxon signed-rank tests. IVIM-DWI and DCE-MRI parameters were correlated with clinical data (C-reactive protein, Harvey-Bradshaw Index), conventional MRI parameters (wall thickness, length of involvement) and MRI activity scores (MaRIA, Clermont). Diagnostic performance of (combined) parameters for differentiation between normal and abnormal bowel was determined using ROC analysis.
RESULTS: The DCE-MRI parameters peak concentration Cpeak, upslope, area-under-the-curve at 60s (AUC60), Ktrans and ve were significantly increased (p<0.023), while IVIM-DWI parameters perfusion fraction (PF) and ADC were significantly decreased (p<0.001) in abnormal bowel segments. None of the DCE-MRI and IVIM-DWI parameters correlated with clinical parameters (p>0.105). DCE-MRI parameters exhibited multiple significant correlations with wall thickness (Cpeak, upslope, AUC60, Ktrans; r range 0.431-0.664, p<0.025) and MaRIA/Clermont scores (Cpeak, AUC60, Ktrans; r range 0.441-0.617, p<0.021). Combined Ktrans+ve+PF+ADC showed highest AUC (0.963) for differentiation between normal and abnormal bowel, while ADC performed best for individual parameters (AUC=0.800).
CONCLUSIONS: DCE-MRI and IVIM-DWI, particularly when used in combination, are promising for non-invasive evaluation of small bowel CD. KEY POINTS: • IVIM-DWI and DCE-MRI parameters were significantly different between normal and abnormal bowel segments in CD patients. • DCE-MRI parameters showed a significant association with wall thickness and MRI activity scores. • Combination of IVIM-DWI and DCE-MRI parameters led to the highest diagnostic performance for differentiation between normal and abnormal bowel segments, while ADC showed the highest diagnostic performance of individual parameters.

Entities:  

Keywords:  Crohn disease; Diffusion magnetic resonance imaging; Perfusion imaging

Mesh:

Substances:

Year:  2018        PMID: 30019143     DOI: 10.1007/s00330-018-5627-4

Source DB:  PubMed          Journal:  Eur Radiol        ISSN: 0938-7994            Impact factor:   5.315


  32 in total

1.  The second European evidence-based Consensus on the diagnosis and management of Crohn's disease: Special situations.

Authors:  Gert Van Assche; Axel Dignass; Walter Reinisch; C Janneke van der Woude; Andreas Sturm; Martine De Vos; Mario Guslandi; Bas Oldenburg; Iris Dotan; Philippe Marteau; Alessandro Ardizzone; Daniel C Baumgart; Geert D'Haens; Paolo Gionchetti; Francisco Portela; Boris Vucelic; Johan Söderholm; Johanna Escher; Sibylle Koletzko; Kaija-Leena Kolho; Milan Lukas; Christian Mottet; Herbert Tilg; Séverine Vermeire; Frank Carbonnel; Andrew Cole; Gottfried Novacek; Max Reinshagen; Epameinondas Tsianos; Klaus Herrlinger; Bas Oldenburg; Yoram Bouhnik; Ralf Kiesslich; Eduard Stange; Simon Travis; James Lindsay
Journal:  J Crohns Colitis       Date:  2009-12-21       Impact factor: 9.071

2.  Dynamic contrast-enhanced MRI of the bowel wall for assessment of disease activity in Crohn's disease.

Authors:  Jasper Florie; Martin N J M Wasser; Kasia Arts-Cieslik; Erik M Akkerman; Peter D Siersema; Jaap Stoker
Journal:  AJR Am J Roentgenol       Date:  2006-05       Impact factor: 3.959

3.  Comparison of magnetic properties of MRI contrast media solutions at different magnetic field strengths.

Authors:  Martin Rohrer; Hans Bauer; Jan Mintorovitch; Martin Requardt; Hanns-Joachim Weinmann
Journal:  Invest Radiol       Date:  2005-11       Impact factor: 6.016

4.  On the scope and interpretation of the Tofts models for DCE-MRI.

Authors:  Steven P Sourbron; David L Buckley
Journal:  Magn Reson Med       Date:  2011-03-07       Impact factor: 4.668

5.  Magnetic resonance imaging for evaluation of Crohn's disease: validation of parameters of severity and quantitative index of activity.

Authors:  Jordi Rimola; Ingrid Ordás; Sonia Rodriguez; Orlando García-Bosch; Montserrat Aceituno; Josep Llach; Carmen Ayuso; Elena Ricart; Julián Panés
Journal:  Inflamm Bowel Dis       Date:  2010-11-08       Impact factor: 5.325

Review 6.  Intravoxel incoherent motion in body diffusion-weighted MRI: reality and challenges.

Authors:  Dow-Mu Koh; David J Collins; Matthew R Orton
Journal:  AJR Am J Roentgenol       Date:  2011-06       Impact factor: 3.959

7.  Active Crohn's disease in the small bowel: evaluation by diffusion weighted imaging and quantitative dynamic contrast enhanced MR imaging.

Authors:  Aytekin Oto; Arda Kayhan; Joshua T B Williams; Xiaobing Fan; Laura Yun; Sanaz Arkani; David T Rubin
Journal:  J Magn Reson Imaging       Date:  2011-03       Impact factor: 4.813

8.  Angiogenesis as a novel component of inflammatory bowel disease pathogenesis.

Authors:  Silvio Danese; Miquel Sans; Carol de la Motte; Cristina Graziani; Gail West; Manijeh H Phillips; Roberto Pola; Sergio Rutella; Joe Willis; Antonio Gasbarrini; Claudio Fiocchi
Journal:  Gastroenterology       Date:  2006-06       Impact factor: 22.682

9.  Evaluation of diffusion-weighted MR imaging for detection of bowel inflammation in patients with Crohn's disease.

Authors:  Aytekin Oto; Fang Zhu; Kirti Kulkarni; Gregory S Karczmar; Jerrold R Turner; David Rubin
Journal:  Acad Radiol       Date:  2009-03-17       Impact factor: 3.173

Review 10.  The natural history of adult Crohn's disease in population-based cohorts.

Authors:  Laurent Peyrin-Biroulet; Edward V Loftus; Jean-Frederic Colombel; William J Sandborn
Journal:  Am J Gastroenterol       Date:  2009-10-27       Impact factor: 10.864

View more
  8 in total

1.  Ability of DWI to characterize bowel fibrosis depends on the degree of bowel inflammation.

Authors:  Xue-Hua Li; Ren Mao; Si-Yun Huang; Zhuang-Nian Fang; Bao-Lan Lu; Jin-Jiang Lin; Shan-Shan Xiong; Min-Hu Chen; Zi-Ping Li; Can-Hui Sun; Shi-Ting Feng
Journal:  Eur Radiol       Date:  2019-01-11       Impact factor: 5.315

2.  IVIM with fractional perfusion as a novel biomarker for detecting and grading intestinal fibrosis in Crohn's disease.

Authors:  Meng-Chen Zhang; Xue-Hua Li; Si-Yun Huang; Ren Mao; Zhuang-Nian Fang; Qing-Hua Cao; Zhong-Wei Zhang; Xu Yan; Min-Hu Chen; Zi-Ping Li; Can-Hui Sun; Shi-Ting Feng
Journal:  Eur Radiol       Date:  2018-12-13       Impact factor: 5.315

3.  Apparent diffusion coefficient for assessing Crohn's disease activity: a meta-analysis.

Authors:  Maximilian Thormann; Bohdan Melekh; Caroline Bär; Maciej Pech; Jazan Omari; Andreas Wienke; Hans-Jonas Meyer; Alexey Surov
Journal:  Eur Radiol       Date:  2022-09-28       Impact factor: 7.034

4.  Evaluation of ileal Crohn's disease response to TNF antagonists: Validation of MR enterography for assessing response. Initial results.

Authors:  Sonja Gordic; Octavia Bane; Shingo Kihira; Steven Peti; Stefanie Hectors; Joana Torres; Judy Cho; Jean-Frederic Colombel; Bachir Taouli
Journal:  Eur J Radiol Open       Date:  2020-01-28

5.  Dynamic contrast-enhanced magnetic resonance imaging and diffusion-weighted imaging in the activity staging of terminal ileum Crohn's disease.

Authors:  Yin-Chen Wu; Ze-Bin Xiao; Xue-Hua Lin; Xian-Ying Zheng; Dai-Rong Cao; Zhong-Shuai Zhang
Journal:  World J Gastroenterol       Date:  2020-10-21       Impact factor: 5.742

6.  Application of Intravoxel Incoherent Motion Diffusion-Weighted Imaging in Predicting and Monitoring Early Efficacy of Anti-Angiogenic Therapy in the C6 Glioma Rat Model.

Authors:  Weishu Hou; Yangyang Xue; Yinfeng Qian; Hongli Pan; Man Xu; Yujun Shen; Xiaohu Li; Yongqiang Yu
Journal:  Front Oncol       Date:  2022-01-28       Impact factor: 6.244

7.  Magnetic resonance enterography and bowel ultrasonography in Saudi Arabian patients with Crohn's disease: A correlation study.

Authors:  Rani Ahmad; Ahmed Abduljabbar; Mohammad Wazzan; Rawan Thabit; Mahmoud Mosli; Omar I Saadah
Journal:  Saudi J Gastroenterol       Date:  2022 May-Jun       Impact factor: 3.214

8.  Test-retest assessment of non-contrast MRI sequences to characterise and quantify the small bowel wall in healthy participants.

Authors:  Ali S Alyami; Hannah G Williams; Konstantinos Argyriou; David Gunn; Victoria Wilkinson-Smith; Jonathan R White; Jaber Alyami; Penny A Gowland; Gordon W Moran; Caroline L Hoad
Journal:  MAGMA       Date:  2021-06-05       Impact factor: 2.310

  8 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.