Literature DB >> 30018067

Sleep quality and noise: comparisons between hospital and home settings.

Rosanna Bevan1, Sarah Grantham-Hill1, Ruth Bowen1, Esther Clayton1, Helen Grice1, Holly Caroline Venditti1, Alice Stickland1, Catherine Mary Hill1,2.   

Abstract

BACKGROUND: Children and their parents report poor sleep in hospital and complain about noise.
OBJECTIVE: To measure sleep quality and noise levels in hospital and compare these with the home environment.
DESIGN: Observational within case-controlled study.
SETTING: Paediatric medical wards at Southampton Children's Hospital and bedrooms at home. PARTICIPANTS AND METHODS: Participants were children aged 3-16 years and their co-sleeping parents. Sleep quality was measured using actigraphy for a maximum of 5 nights in each setting. Median sound levels at the bedside were monitored overnight in a subgroup in both settings. MAIN OUTCOME MEASURES: Total sleep time, sleep efficiency, median sound levels overnight.
RESULTS: 40 children and 16 mothers completed actigraphy in both settings. Children had on average 62.9 min, and parents 72.8 min, per night less sleep in hospital than at home. Both children and parents had poorer sleep quality in hospital than at home: mean sleep efficiency 77.0% vs 83.2% for children and 77.1% vs 88.9% for parents, respectively. Median sound levels in hospital measured in 8 children averaged 48.6 dBA compared with 34.7 dBA at home and exceeded World Health Organization recommendations of 30 dB.
CONCLUSIONS: Children and their mothers have poor quality sleep in paediatric wards. This may affect the child's behaviour, recovery and pain tolerance. Sleep deprivation adds to parental burden and stress. Sound levels are significantly raised in hospital and may contribute to poor sleep. Reduction in the level of noise might lead to an improvement in sleep, affecting the quality of stay of both parent and child. © Author(s) (or their employer(s)) 2019. No commercial re-use. See rights and permissions. Published by BMJ.

Entities:  

Keywords:  environmental noise; paediatric ward; sleep quality; sound level

Mesh:

Year:  2018        PMID: 30018067     DOI: 10.1136/archdischild-2018-315168

Source DB:  PubMed          Journal:  Arch Dis Child        ISSN: 0003-9888            Impact factor:   3.791


  4 in total

1.  Development of a suite of metrics and indicators for children's nursing using consensus methodology.

Authors:  Maria Brenner; Catherine Browne; Anne Gallen; Susanna Byrne; Ciara White; Mary Nolan
Journal:  J Clin Nurs       Date:  2019-04-04       Impact factor: 3.036

2.  Concurrence of sleep problems and distress: prevalence and determinants in parents of children with cancer.

Authors:  Niki Rensen; Lindsay M H Steur; Sasja A Schepers; Johannes H M Merks; Annette C Moll; Martha A Grootenhuis; Gertjan J L Kaspers; Raphaële R L van Litsenburg
Journal:  Eur J Psychotraumatol       Date:  2019-07-22

3.  Objective Sleep Characteristics and Factors Associated With Sleep Duration and Waking During Pediatric Hospitalization.

Authors:  Robyn Stremler; Samantha Micsinszki; Sherri Adams; Christopher Parshuram; Eleanor Pullenayegum; Shelly K Weiss
Journal:  JAMA Netw Open       Date:  2021-04-01

4.  Associations between cumulative risk, childhood sleep duration, and body mass index across childhood.

Authors:  Tiffany Phu; Jenalee R Doom
Journal:  BMC Pediatr       Date:  2022-09-06       Impact factor: 2.567