Literature DB >> 30015749

Analysis of Different Approaches for Clinical Cochlear Coverage Evaluation After Cochlear Implantation.

Daniel Schurzig1, Max Eike Timm2, Cornelia Batsoulis1, Samuel John3, Thomas Lenarz2.   

Abstract

HYPOTHESIS: Methods for cochlear coverage determination vary in their accuracy and are hence not equally reliable.
BACKGROUND: The audiological outcome after cochlear implantation is known to depend on several factors. One factor shown to positively correlate with speech perception is the insertion angle. This parameter is one of the ways to describe the fraction of the cochlea spiral exposed to electric stimulation after implantation, also known as cochlear coverage, which itself is dependent on the length and type of electrode array as well as the size and shape of the implanted cochlea. While the assessment of cochlear coverage as the insertion angle is quick and uncomplicated, the accuracy of representing the relative fraction of the cochlea exposed to electric stimulation by this single measurement value remains unknown.
METHODS: Both the cochlea spiral and implanted electrode array of N = 10 cochlear implant patients were traced within clinical imaging data and processed to derive the respective cochlear coverage values. These values were compared to ones derived with alternative measures like the insertion angle as well as other methods to yield the accuracy and reliability of these approaches.
RESULTS: The insertion angle as well as two novel approaches were found to be superior to all other analyzed assessment options and well suited for clinical cochlear coverage evaluations.
CONCLUSION: Insertion angle measurements are well suited for cochlear coverage determination, especially regarding retrospective analyses. Prospective studies independent of anatomical irregularities should be performed with the newly proposed approaches.

Entities:  

Mesh:

Year:  2018        PMID: 30015749     DOI: 10.1097/MAO.0000000000001904

Source DB:  PubMed          Journal:  Otol Neurotol        ISSN: 1531-7129            Impact factor:   2.311


  5 in total

1.  Preoperative prediction of angular insertion depth of lateral wall cochlear implant electrode arrays.

Authors:  Mohammad M R Khan; Robert F Labadie; Jack H Noble
Journal:  J Med Imaging (Bellingham)       Date:  2020-06-03

2.  Cochlear Duct Length Measurements in Computed Tomography and Magnetic Resonance Imaging Using Newly Developed Techniques.

Authors:  Johannes Taeger; Franz Tassilo Müller-Graff; Lukas Ilgen; Phillip Schendzielorz; Rudolf Hagen; Tilman Neun; Kristen Rak
Journal:  OTO Open       Date:  2021-09-24

3.  Implementation of secondary reconstructions of flat-panel volume computed tomography (fpVCT) and otological planning software for anatomically based cochlear implantation.

Authors:  Franz-Tassilo Müller-Graff; Lukas Ilgen; Philipp Schendzielorz; Johannes Voelker; Johannes Taeger; Anja Kurz; Rudolf Hagen; Tilmann Neun; Kristen Rak
Journal:  Eur Arch Otorhinolaryngol       Date:  2021-06-08       Impact factor: 3.236

4.  Correlation of Electrically Evoked Compound Action Potential Amplitude Growth Function Slope and Anamnestic Parameters in Cochlear Implant Patients-Identification of Predictors for the Neuronal Health Status.

Authors:  Lutz Gärtner; Katharina Klötzer; Thomas Lenarz; Verena Scheper
Journal:  Life (Basel)       Date:  2021-03-05

5.  Variations in microanatomy of the human modiolus require individualized cochlear implantation.

Authors:  Markus Pietsch; Daniel Schurzig; Rolf Salcher; Athanasia Warnecke; Peter Erfurt; Thomas Lenarz; Andrej Kral
Journal:  Sci Rep       Date:  2022-03-23       Impact factor: 4.996

  5 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.