We evaluated quantitation accuracy of the specific binding ratio (SBR) and specific uptake ratio (SUR) of dopamine transporter for various correction methods by using a novel three-dimensional striatum digital brain (3D-SDB) phantom comprised of segments containing the striatum, ventricle, brain parenchyma, and skull bone extracted from T2-weighted MR images. A process image was reconstructed by projection data sets with blurring, scatter, and attenuation from 3D-SDB phantom data. A 3D-iterative reconstruction algorithm was used without correction (OSEM), or with scatter (SC), attenuation (AC), AC + SC (ACSC), AC + resolution recovery (RR; ACRR), SC + RR (SCRR), AC + SC + RR (ACSCRR), AC + SC + RR + partial volume (PVC; ACSCRRP), and AC + SC + RR + PVC + ventricle (ACSCRRPV). Data were then quantified using SBR and SUR. Differences between measured and true SBR values were (in order): ACSCRR < ACSC < ACRR < AC < SCRR < SC < OSEM: the maximal error was 45.3%. The trend of differences between measured and true SUR values was similar to that of SBR; maximal error was 65%. The ACSCRR-corrected SUR, which was closer to the true value, was underestimated by 30.4%. However, the ACSCRRP-corrected SUR was underestimated by a maximum of 22.5%. The SUR in the ACSCRRPV was underestimated by 6.2%. The accuracy of quantitation was improved using various types of compensation and correction. Accuracy improved more for the SUR when PVC and ventricle correction were added.

Entities:  

Keywords:  Partial volume correction; Specific binding ratio; Specific uptake ratio; Ventricle correction

Mesh:

Substances:

Year:  2018        PMID: 30014182     DOI: 10.1007/s12194-018-0468-z

Source DB:  PubMed          Journal:  Radiol Phys Technol        ISSN: 1865-0333


  23 in total

Review 1.  SPECT imaging evaluation in movement disorders: far beyond visual assessment.

Authors:  Kosmas Badiavas; Elisavet Molyvda; Ioannis Iakovou; Magdalini Tsolaki; Kyriakos Psarrakos; Nikolaos Karatzas
Journal:  Eur J Nucl Med Mol Imaging       Date:  2010-12-02       Impact factor: 9.236

2.  [125I] beta-CIT-FE and [125I] beta-CIT-FP are superior to [125I] beta-CIT for dopamine transporter visualization: autoradiographic evaluation in the human brain.

Authors:  I Günther; H Hall; C Halldin; C G Swahn; L Farde; G Sedvall
Journal:  Nucl Med Biol       Date:  1997-10       Impact factor: 2.408

3.  Improved methods for image registration.

Authors:  N M Alpert; D Berdichevsky; Z Levin; E D Morris; A J Fischman
Journal:  Neuroimage       Date:  1996-02       Impact factor: 6.556

4.  Accurate differentiation of parkinsonism and essential tremor using visual assessment of [123 I]-FP-CIT SPECT imaging: The [123 I]-FP-CIT study group.

Authors:  Hani T S Benamer; Jim Patterson; Donald G Grosset; J Booij; K de Bruin; E van Royen; J D Speelman; M H I M Horstink; H J W A Sips; R A Dierckx; J Versijpt; D Decoo; C Van Der Linden; D M Hadley; M Doder; A J Lees; D C Costa; S Gacinovic; W H Oertel; O Pogarell; H Hoeffken; K Joseph; K Tatsch; J Schwarz; V Ries
Journal:  Mov Disord       Date:  2000-05       Impact factor: 10.338

5.  Comparison of diagnostic utility of semi-quantitative analysis for DAT-SPECT for distinguishing DLB from AD.

Authors:  Soichiro Shimizu; Nayuta Namioka; Daisuke Hirose; Hidekazu Kanetaka; Kentaro Hirao; Hirokuni Hatanaka; Naoto Takenoshita; Yoshitsugu Kaneko; Yusuke Ogawa; Akito Tsugawa; Takahiko Umahara; Hirofumi Sakurai; Haruo Hanyu
Journal:  J Neurol Sci       Date:  2017-03-27       Impact factor: 3.181

6.  Reduction in camera-specific variability in [(123)I]FP-CIT SPECT outcome measures by image reconstruction optimized for multisite settings: impact on age-dependence of the specific binding ratio in the ENC-DAT database of healthy controls.

Authors:  Ralph Buchert; Andreas Kluge; Livia Tossici-Bolt; John Dickson; Marcus Bronzel; Catharina Lange; Susanne Asenbaum; Jan Booij; L Özlem Atay Kapucu; Claus Svarer; Pierre-Malick Koulibaly; Flavio Nobili; Marco Pagani; Osama Sabri; Terez Sera; Klaus Tatsch; Thierry Vander Borght; Koen Van Laere; Andrea Varrone; Hidehiro Iida
Journal:  Eur J Nucl Med Mol Imaging       Date:  2016-01-27       Impact factor: 9.236

7.  Optimal ROI setting on the anatomically normalized I-123 FP-CIT images using high-resolution SPECT.

Authors:  Masanari Nonokuma; Yasuo Kuwabara; Kosuke Hida; Tomonobu Tani; Koichi Takano; Kengo Yoshimitsu
Journal:  Ann Nucl Med       Date:  2016-07-20       Impact factor: 2.668

8.  The impact of reconstruction and scanner characterisation on the diagnostic capability of a normal database for [123I]FP-CIT SPECT imaging.

Authors:  John C Dickson; Livia Tossici-Bolt; Terez Sera; Jan Booij; Morten Ziebell; Silvia Morbelli; Susanne Assenbaum-Nan; Thierry Vander Borght; Marco Pagani; Ozlem L Kapucu; Swen Hesse; Koen Van Laere; Jacques Darcourt; Andrea Varrone; Klaus Tatsch
Journal:  EJNMMI Res       Date:  2017-01-24       Impact factor: 3.138

9.  [123I]FP-CIT ENC-DAT normal database: the impact of the reconstruction and quantification methods.

Authors:  Livia Tossici-Bolt; John C Dickson; Terez Sera; Jan Booij; Susanne Asenbaun-Nan; Maria C Bagnara; Thierry Vander Borght; Cathrine Jonsson; Robin de Nijs; Swen Hesse; Pierre M Koulibaly; Umit O Akdemir; Michel Koole; Klaus Tatsch; Andrea Varrone
Journal:  EJNMMI Phys       Date:  2017-01-28

10.  The basal ganglia matching tools package for striatal uptake semi-quantification: description and validation.

Authors:  Piero Calvini; Guido Rodriguez; Fabrizio Inguglia; Alessandro Mignone; Ugo Paolo Guerra; Flavio Nobili
Journal:  Eur J Nucl Med Mol Imaging       Date:  2007-02-08       Impact factor: 10.057

View more
  2 in total

1.  Combination of compressed sensing-based iterative reconstruction and offset acquisition for I-123 FP-CIT SPECT: a simulation study.

Authors:  Norikazu Matsutomo; Takeyuki Hashimoto; Mitsuha Fukami; Tomoaki Yamamoto
Journal:  Asia Ocean J Nucl Med Biol       Date:  2022

2.  Novel approach to semi-quantification of tracer accumulation in dopamine transporter scan.

Authors:  Yoshinori Ito; Naotoshi Fujita; Kazuhiro Hara; Tomohiro Tada; Shinji Abe; Masahisa Katsuno; Shinji Naganawa; Katsuhiko Kato
Journal:  J Appl Clin Med Phys       Date:  2022-05-10       Impact factor: 2.243

  2 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.