Feasibility of quantitative ultrashort echo time (UTE)-based methods for MRI of peripheral nerve.

Shu-Juan Fan1, Jonathan Wong2, Xin Cheng1,2, Ya-Jun Ma1, Eric Y Chang1,2, Jiang Du1, Sameer B Shah2,3.   

Abstract

Peripheral nerves are a composite tissue consisting of neurovascular elements packaged within a well-organized extracellular matrix. Their composition, size, and anatomy render nerves a challenging medical imaging target. In contrast to morphological MRI, which represents the predominant approach to nerve imaging, quantitative MRI sequences can provide information regarding tissue composition. Here, we applied standard clinical Carr-Purcell-Meiboom-Gill (CPMG) and experimental three-dimensional (3D) ultrashort echo time (UTE) Cones sequences for quantitative nerve imaging including T2 measurement with single-component analysis, T2 * measurement with single-component and bi-component analyses, and magnetization transfer ratio (MTR) analysis. We demonstrated the feasibility and the high quality of single-component T2 *, bi-component T2 *, and MTR approaches to analyze nerves imaged with clinically deployed 3D UTE Cones pulse sequences. For 24 single fascicles from eight nerves, we measured a mean single-component T2 * of 22.6 ±8.9 ms, and a short T2 * component (STC) with a mean T2 * of 1.7 ±1.0 ms and a mean fraction of (6.74 ±4.31)% in bi-component analysis. For eight whole nerves, we measured a mean single-component T2 * of 16.7 ±2.2 ms, and an STC with a mean T2 * of 3.0 ±1.0 ms and a mean fraction of (15.56 ±7.07)% in bi-component analysis. For nine fascicles from three healthy nerves, we measured a mean MTR of (25.2 ±1.9)% for single fascicles and a mean MTR of (23.6 ±0.9)% for whole nerves. No statistically significant correlation was observed between any MRI parameter and routine histological outcomes, perhaps due to the small sample size and lack of apparent sample pathology. Overall, we have successfully demonstrated the feasibility of measuring quantitative MR outcomes ex vivo, which might reflect features of nerve structure and macromolecular content. These methods should be validated comprehensively on a larger and more diverse set of nerve samples, towards the interpretation of in vivo outcomes. These approaches have new and broad implications for the management of nerve disease, injury, and repair.
© 2018 John Wiley & Sons, Ltd.

Entities:  

Keywords:  MRI; UTE; peripheral nerve; quantitative imaging

Mesh:

Year:  2018        PMID: 30011103      PMCID: PMC6310234          DOI: 10.1002/nbm.3948

Source DB:  PubMed          Journal:  NMR Biomed        ISSN: 0952-3480            Impact factor:   4.044


  31 in total

1.  Magic angle effects in MR neurography.

Authors:  Karyn E Chappell; Matthew D Robson; Amanda Stonebridge-Foster; Alan Glover; Joanna M Allsop; Andreanna D Williams; Amy H Herlihy; Jill Moss; Philip Gishen; Graeme M Bydder
Journal:  AJNR Am J Neuroradiol       Date:  2004-03       Impact factor: 3.825

2.  Visualization of peripheral nerve degeneration and regeneration: monitoring with diffusion tensor tractography.

Authors:  Takehiko Takagi; Masaya Nakamura; Masayuki Yamada; Keigo Hikishima; Suketaka Momoshima; Kanehiro Fujiyoshi; Shinsuke Shibata; Hirotaka James Okano; Yoshiaki Toyama; Hideyuki Okano
Journal:  Neuroimage       Date:  2008-10-02       Impact factor: 6.556

Review 3.  MRI of peripheral nerves.

Authors:  Kimberly K Amrami; Joel P Felmlee; Robert J Spinner
Journal:  Neurosurg Clin N Am       Date:  2008-10       Impact factor: 2.509

4.  Peripheral nerve MRI: precision and reproducibility of T2*-derived measurements at 3.0-T : a feasibility study.

Authors:  Alberto Tagliafico; Bianca Bignotti; Giulio Tagliafico; Carlo Martinoli
Journal:  Skeletal Radiol       Date:  2015-01-30       Impact factor: 2.199

Review 5.  UTE imaging in the musculoskeletal system.

Authors:  Eric Y Chang; Jiang Du; Christine B Chung
Journal:  J Magn Reson Imaging       Date:  2014-07-16       Impact factor: 4.813

6.  Anisotropy of NMR properties of tissues.

Authors:  R M Henkelman; G J Stanisz; J K Kim; M J Bronskill
Journal:  Magn Reson Med       Date:  1994-11       Impact factor: 4.668

7.  UTE imaging with simultaneous water and fat signal suppression using a time-efficient multispoke inversion recovery pulse sequence.

Authors:  Michael Carl; Graeme M Bydder; Jiang Du
Journal:  Magn Reson Med       Date:  2015-08-26       Impact factor: 4.668

8.  Experimental allergic encephalomyelitis and multiple sclerosis: lesion characterization with magnetization transfer imaging.

Authors:  V Dousset; R I Grossman; K N Ramer; M D Schnall; L H Young; F Gonzalez-Scarano; E Lavi; J A Cohen
Journal:  Radiology       Date:  1992-02       Impact factor: 11.105

9.  Peripheral Nerve Diffusion Tensor Imaging: Assessment of Axon and Myelin Sheath Integrity.

Authors:  A Heckel; M Weiler; A Xia; M Ruetters; M Pham; M Bendszus; S Heiland; P Baeumer
Journal:  PLoS One       Date:  2015-06-26       Impact factor: 3.240

10.  In Vivo MR Microneurography of the Tibial and Common Peroneal Nerves.

Authors:  Paolo F Felisaz; Eric Y Chang; Irene Carne; Stefano Montagna; Francesco Balducci; Giulia Maugeri; Anna Pichiecchio; Fabrizio Calliada; Maurizia Baldi; Stefano Bastianello
Journal:  Radiol Res Pract       Date:  2014-12-07
View more
  1 in total

Review 1.  Peripheral nerve magnetic resonance imaging.

Authors:  Yongsheng Chen; E Mark Haacke; Jun Li
Journal:  F1000Res       Date:  2019-10-28
  1 in total