Literature DB >> 30008772

Supra-annular sizing for transcatheter valve implantation in bicuspid aortic stenosis.

Raban Jeger1, Oliver Reuthebuch1, Gregor Fahrni1, Jean-Claude Laborde2, Rolf Vogel3, Christoph Kaiser1.   

Abstract

Entities:  

Year:  2018        PMID: 30008772      PMCID: PMC6041830          DOI: 10.5114/aic.2018.76411

Source DB:  PubMed          Journal:  Postepy Kardiol Interwencyjnej        ISSN: 1734-9338            Impact factor:   1.426


× No keyword cloud information.

Introduction

Transcatheter aortic valve implantation (TAVI) is an established treatment option for symptomatic severe aortic stenosis in high [1] and intermediate risk patients [2]. With a prevalence of 1% to 2% in countries outside China, bicuspid aortic valve (BAV) disease is a common congenital malformation [3] that often results in premature aortic stenosis. Since BAV represents a challenge for interventional treatment [4], it traditionally has been considered as a relative contraindication against TAVI. The Lotus valve (Boston Scientific Corp, Marlborough MA) is a mechanically expandable, fully repositionable and retrievable second-generation TAVI prosthesis with an outer adaptive seal that facilitates accurate positioning, early valve function, and hemodynamic stability during deployment, and minimizes paravalvular leakage [5]. Therefore, it might be a good treatment option for BAV stenosis. For planning TAVI procedures, an in-depth analysis of multidetector computed tomography (MDCT) images is crucial. In most reports of interventional treatment of BAV stenosis, preprocedural measurements were done according to current guidelines [6]. However, such measurements might lead to inaccurate annular sizing and prosthesis selection in BAV disease. Specifically, measurement of the basal ring may lead to the selection of too large prostheses, potentially leading to suboptimal results, or may make the intervention impossible due to non-availability of the necessary large valve sizes.

Aim

Therefore, an alternative process of measurement may be preferred. We therefore aimed to use a new algorithm for MDCT analysis, i.e., supra-annular measurement of the valve opening area at the level of the maximal calcification, to assess the correct aortic valve area opening, and compared it to the conventional analysis algorithm in terms of aortic valve area and diameters in a series of patients with severe BAV stenosis undergoing TAVI using the mechanically expandable Lotus valve.

Material and methods

Between January 2015 and February 2017, patients with severe symptomatic aortic stenosis undergoing TAVI at the University Hospital Basel, Switzerland, were screened for the presence of BAV. Before the intervention, patients underwent transthoracic echocardiography, coronary angiography, and MDCT, and were reviewed by the institutional heart team to determine the best treatment approach. Bicuspid aortic valve patients underwent TAVI using Lotus valves via the transfemoral or transsubclavian route, as indicated. Data were collected prospectively, and all patients signed informed consent to be followed within a registry. The study was approved by the responsible ethics committee. The preprocedural MDCT was both ECG-gated and contrast-enhanced and acquired following established institutional scan protocols. All MDCT datasets were evaluated by a single experienced reader for quantitative measurements using the 3mensio software (Pie Medical Imaging BV, Maastricht, The Netherlands) and by two additional readers to define valve morphology. Valve morphology was classified according to the MDCT data [7]. Quantitative analysis included measurements of annular dimensions by means of planimetry using maximal and minimal diameters and perimeter in systole, and was performed according to current guidelines [6]. In addition to the conventional annular measurement, supra-annular measurement was done measuring the maximal length of the valve opening (intercommissural length) and a second diameter perpendicular to this maximal diameter at the level of the maximal leaflet calcification, again measured in systole. Effective valve size was chosen according to the supra-annular measurement. Follow-up including clinical assessment and transthoracic echocardiography was done after 30 days. Study endpoints included the Valve Academic Research Consortium-2 criteria [8] and echocardiographic data such as aortic valve gradient, degree of aortic regurgitation, and left ventricular ejection fraction. Postprocedural aortic regurgitation was defined as the sum of para- and transvalvular regurgitation, while the severity was graded as none or trivial, mild, moderate, or severe by means of qualitative assessment.

Statistical analysis

Statistical analyses were done using the GraphPad software (GraphPad Software Inc, La Jolla CA). Continuous variables are presented as mean ± standard deviation and compared with Student’s t test. Categorical variables are presented as percentages. All hypothesis testing was 2-tailed, and a p-value of < 0.05 was considered statistically significant.

Results

Baseline characteristics

From 253 patients undergoing TAVI, 108 (42.7%) were treated with an Edwards Sapien 3, 73 (28.9%) with a Lotus, 47 (18.5%) with a Portico, 11 (4.3%) with a CoreValve Evolut R, 8 (3.2%) with a JenaValve, 5 (2%) with a Direct Flow, and 1 (0.4%) with an NVT valve. Overall, there were 8 (3.2%) patients with BAV, who were treated with a Lotus. These patients had a mean age of 78.8 ±4.9 years with a logistic EuroSCORE II of 3.1 ±2.0% and suffered from either dyspnea or angina pectoris. Mean aortic gradient was 51.43 ±12.75 mm Hg with an aortic valve area of 0.83 ±0.27 cm2. Anatomy of the valve was in 50% BAV-RL type 3, in 37.5% BAV-AP type 1, and in 12.5% BAV-RL type 4 [7]. The baseline demographic, echocardiographic, and MDCT data are summarized in Table I.
Table I

Baseline characteristics

ParameterValue
Demographic data:
 Age [years]78.75 ±4.92
 Sex female (%)38
 EuroSCORE II (%)3.05 ±2.01
 Patients’ history
 Arterial hypertension (%)88
 Hyperlipidemia (%)50
 Diabetes mellitus (%)38
 Family history (%)0
 Current smoking (%)63
 Prior myocardial infarction (%)13
 Prior coronary artery bypass graft surgery (%)13
 Prior stroke (%)0
 Renal failure (%)13
 Atrial fibrillation (%)50
Echocardiographic data:
 Left ventricular ejection fraction (%)58.0 ±7.82
 Maximal aortic gradient [mm Hg]82.0 ±19.2
 Mean aortic gradient [mm Hg]54.43 ±12.75
 Aortic valve area [cm2]0.83 ±0.27
Clinical data:
 Dyspnea (%):
   I0
  II25
  III62.5
  IV12.5
 Angina pectoris (%):
  10
  237.5
  30
  40
Multidetector CT data:
 Bicuspid aortic valve type (%):
  BAV-AP type 137.5
  BAV-AP type 20
  BAV-RL type 350
  BAV-RL type 412.5
  BAV-RL type 50

Continuous variables are presented as mean ± standard deviation. Categorical variables are presented as percentages.

Baseline characteristics Continuous variables are presented as mean ± standard deviation. Categorical variables are presented as percentages.

Multidetector computed tomography measurements

Supra-annular measurement resulted in both smaller valve area (436.54 ±72.83 mm2 vs. 536.73 ±88.33 mm2, p = 0.0267) and mean diameter (23.49 ±1.98 mm vs. 26.06 ±2.18 mm, p = 0.0271) compared with annular measurement, which resulted in the selection of smaller valve sizes or made the use of the Lotus valve possible at all, respectively (Figure 1). While Lotus valve implantation was not possible with conventional measurement in 37.5% of cases, supra-annular measurement revealed a sufficient annular size in all patients.
Figure 1

Valve size selection according to annular and supra-annular measurements

Black – too large for Lotus, dark gray – Lotus 27 mm, light gray – Lotus 25 mm, white – Lotus 23 mm.

Valve size selection according to annular and supra-annular measurements Black – too large for Lotus, dark gray – Lotus 27 mm, light gray – Lotus 25 mm, white – Lotus 23 mm.

Outcome

Patients underwent TAVI in 87.5% of cases via the transfemoral and in 12.5% of cases via the transsubclavian route. Procedural success was 100%. The implantation of a Lotus valve resulted in a decrease of both peak and mean gradient to 26.25 ±5.12 and 14.43 ±6.58 mm Hg at 30 days, respectively (both p < 0.0001). Regarding clinical endpoints at 30 days, 2 patients underwent permanent pacemaker implantation due a high-degree AV block (25%) and one patient suffered from a valve thrombosis (12.5%), while no patients suffered from either death or stroke. There was no aortic regurgitation at follow-up.

Discussion

Due to its specific anatomic characteristics, BAV stenosis is a challenge for interventional treatment [4]. Registry data show that TAVI in BAV stenosis compared with tricuspid aortic valve stenosis is associated with lower rates of procedural success, higher rates of pacemaker implantation, and more paravalvular leakage; however, long-term mortality was similar [9-11]. While first-generation TAVI prostheses were associated with higher rates of aortic root injury and paravalvular leakage, second-generation prostheses showed similar, favorable results for tricuspid and bicuspid aortic valves, with low rates of annular rupture, relevant aortic regurgitation, or second valve implantation [10, 12]. Based on its mechanical properties, the Lotus valve might be ideal to prevent aortic root injury and regurgitation, specifically in high-risk patients with BAV stenosis. Accordingly, early reports of interventional treatment of BAV stenosis with the Lotus valve showed a good clinical and hemodynamic result without relevant paravalvular leakage [13, 14]. The Lotus valve is available in three sizes, i.e., 23 mm, 25 mm, and 27 mm. Therefore, it can be used for diameters of up to 27 mm only, which limits the use in large aortic annuli. Currently, the use of the Lotus valve has been suspended due to technical issues, but its return to the market is expected soon. Bicuspid aortic valve is characterized by the presence of only two functional cusps and an oval orifice, and can be classified by different systems [7, 15]. The number of detected raphes can be used to group BAV into the 3 following types: type 0 (no raphe); type 1 (1 raphe); and, type 2 (2 raphes) [15]. Other classification systems use imaging modalities such as MDCT for phenotypic classification that has been used in the current analysis. In this classification system, two main types are defined, i.e., fusion of the right and left coronary cusp (type BAV-AP) and fusion of the right or left coronary cusp and the non-coronary cusp (BAV-RL) with a subdivision in types 1 and 2 in BAV-AP and 3 to 5 in BAV-RL [7]. Current guidelines for preprocedural MDCT require that annular sizing and prosthesis selection are based on a basal ring that is measured at the level immediately below the 3 lowest insertion points of the aortic cusps in systole [6]. In the current analysis, an additional supra-annular measurement of the valve opening area at the level of maximal leaflet calcification was performed and showed a considerable lower valve area, which resulted in the choice of smaller valves and allowed the Lotus valve to be used in all cases, which was not possible with conventional measurement only. Of note, the unique properties of repositionability and retrievability combined with the leak tightness of the Lotus valve made it possible to choose smaller valves without risk of embolization and aortic regurgitation, which resulted in favorable clinical outcomes. This analysis has some limitations. In the present study, we did not compare tricuspid vs. bicuspid valves from our database. Therefore, there is no formal comparison between the two anatomical groups. In addition, the small number of patients in the present case series does not allow the results to be generalized to a larger number of patients and precludes definitive conclusions regarding the comparison of the two MDCT measurement algorithms regarding outcome.

Conclusions

Bicuspid aortic valve stenosis may be treated with good success with TAVI in a wide array of patients if MDCT measurements are performed accurately. Supra-annular measurements in combination with conventional annular measurements might optimize the pre-interventional evaluation of the patients, and second generation TAVI prostheses such as the Lotus valve might be a good solution to accommodate BAV anatomy.
  15 in total

1.  A classification system for the bicuspid aortic valve from 304 surgical specimens.

Authors:  Hans-H Sievers; Claudia Schmidtke
Journal:  J Thorac Cardiovasc Surg       Date:  2007-05       Impact factor: 5.209

2.  Transcatheter versus surgical aortic-valve replacement in high-risk patients.

Authors:  Craig R Smith; Martin B Leon; Michael J Mack; D Craig Miller; Jeffrey W Moses; Lars G Svensson; E Murat Tuzcu; John G Webb; Gregory P Fontana; Raj R Makkar; Mathew Williams; Todd Dewey; Samir Kapadia; Vasilis Babaliaros; Vinod H Thourani; Paul Corso; Augusto D Pichard; Joseph E Bavaria; Howard C Herrmann; Jodi J Akin; William N Anderson; Duolao Wang; Stuart J Pocock
Journal:  N Engl J Med       Date:  2011-06-05       Impact factor: 91.245

3.  SCCT expert consensus document on computed tomography imaging before transcatheter aortic valve implantation (TAVI)/transcatheter aortic valve replacement (TAVR).

Authors:  Stephan Achenbach; Victoria Delgado; Jörg Hausleiter; Paul Schoenhagen; James K Min; Jonathon A Leipsic
Journal:  J Cardiovasc Comput Tomogr       Date:  2012-11-14

Review 4.  Performance of transcatheter aortic valve implantation in patients with bicuspid aortic valve: systematic review.

Authors:  Altayyeb Yousef; Trevor Simard; Ali Pourdjabbar; John Webb; Derek So; Aun-Yeong Chong; Christopher Glover; Michel Le May; Benjamin Hibbert; Marino Labinaz
Journal:  Int J Cardiol       Date:  2014-07-11       Impact factor: 4.164

5.  Transcatheter Aortic Valve Replacement With Early- and New-Generation Devices in Bicuspid Aortic Valve Stenosis.

Authors:  Sung-Han Yoon; Thierry Lefèvre; Jung-Ming Ahn; Gidon Y Perlman; Danny Dvir; Azeem Latib; Marco Barbanti; Florian Deuschl; Ole De Backer; Philipp Blanke; Thomas Modine; Gregor Pache; Franz-Josef Neumann; Philipp Ruile; Takahide Arai; Yohei Ohno; Hidehiro Kaneko; Edgar Tay; Niklas Schofer; Erik W Holy; Ngai H V Luk; Gerald Yong; Qingsheng Lu; William K F Kong; Jimmy Hon; Hsien-Li Kao; Michael Lee; Wei-Hsian Yin; Duk-Woo Park; Soo-Jin Kang; Seung-Whan Lee; Young-Hak Kim; Cheol Whan Lee; Seong-Wook Park; Hyo-Soo Kim; Christian Butter; Omar K Khalique; Ulrich Schaefer; Fabian Nietlispach; Susheel K Kodali; Martin B Leon; Jian Ye; Bernard Chevalier; Jonathon Leipsic; Victoria Delgado; Jeroen J Bax; Corrado Tamburino; Antonio Colombo; Lars Søndergaard; John G Webb; Seung-Jung Park
Journal:  J Am Coll Cardiol       Date:  2016-09-13       Impact factor: 24.094

6.  Updated standardized endpoint definitions for transcatheter aortic valve implantation: the Valve Academic Research Consortium-2 consensus document.

Authors:  A Pieter Kappetein; Stuart J Head; Philippe Généreux; Nicolo Piazza; Nicolas M van Mieghem; Eugene H Blackstone; Thomas G Brott; David J Cohen; Donald E Cutlip; Gerrit-Anne van Es; Rebecca T Hahn; Ajay J Kirtane; Mitchell W Krucoff; Susheel Kodali; Michael J Mack; Roxana Mehran; Josep Rodés-Cabau; Pascal Vranckx; John G Webb; Stephan Windecker; Patrick W Serruys; Martin B Leon
Journal:  EuroIntervention       Date:  2012-11-22       Impact factor: 6.534

7.  Outcomes in Transcatheter Aortic Valve Replacement for Bicuspid Versus Tricuspid Aortic Valve Stenosis.

Authors:  Sung-Han Yoon; Sabine Bleiziffer; Ole De Backer; Victoria Delgado; Takahide Arai; Johannes Ziegelmueller; Marco Barbanti; Rahul Sharma; Gidon Y Perlman; Omar K Khalique; Erik W Holy; Smriti Saraf; Florian Deuschl; Buntaro Fujita; Philipp Ruile; Franz-Josef Neumann; Gregor Pache; Masao Takahashi; Hidehiro Kaneko; Tobias Schmidt; Yohei Ohno; Niklas Schofer; William K F Kong; Edgar Tay; Daisuke Sugiyama; Hiroyuki Kawamori; Yoshio Maeno; Yigal Abramowitz; Tarun Chakravarty; Mamoo Nakamura; Shingo Kuwata; Gerald Yong; Hsien-Li Kao; Michael Lee; Hyo-Soo Kim; Thomas Modine; S Chiu Wong; Francesco Bedgoni; Luca Testa; Emmanuel Teiger; Christian Butter; Stephan M Ensminger; Ulrich Schaefer; Danny Dvir; Philipp Blanke; Jonathon Leipsic; Fabian Nietlispach; Mohamed Abdel-Wahab; Bernard Chevalier; Corrado Tamburino; David Hildick-Smith; Brian K Whisenant; Seung-Jung Park; Antonio Colombo; Azeem Latib; Susheel K Kodali; Jeroen J Bax; Lars Søndergaard; John G Webb; Thierry Lefèvre; Martin B Leon; Raj Makkar
Journal:  J Am Coll Cardiol       Date:  2017-03-18       Impact factor: 24.094

8.  1-Year Outcomes With the Fully Repositionable and Retrievable Lotus Transcatheter Aortic Replacement Valve in 120 High-Risk Surgical Patients With Severe Aortic Stenosis: Results of the REPRISE II Study.

Authors:  Ian T Meredith; Darren L Walters; Nicolas Dumonteil; Stephen G Worthley; Didier Tchétché; Ganesh Manoharan; Daniel J Blackman; Gilles Rioufol; David Hildick-Smith; Robert J Whitbourn; Thierry Lefèvre; Rüdiger Lange; Ralf Müller; Simon Redwood; Ted E Feldman; Dominic J Allocco; Keith D Dawkins
Journal:  JACC Cardiovasc Interv       Date:  2016-02-22       Impact factor: 11.195

9.  Comparison of the effectiveness of transcatheter aortic valve implantation in patients with stenotic bicuspid versus tricuspid aortic valves (from the German TAVI Registry).

Authors:  Timm Bauer; Axel Linke; Horst Sievert; Philipp Kahlert; Rainer Hambrecht; Georg Nickenig; Karl Eugen Hauptmann; Stefan Sack; Ulrich Gerckens; Steffen Schneider; Uwe Zeymer; Ralf Zahn
Journal:  Am J Cardiol       Date:  2013-11-09       Impact factor: 2.778

10.  Transcatheter or Surgical Aortic-Valve Replacement in Intermediate-Risk Patients.

Authors:  Martin B Leon; Craig R Smith; Michael J Mack; Raj R Makkar; Lars G Svensson; Susheel K Kodali; Vinod H Thourani; E Murat Tuzcu; D Craig Miller; Howard C Herrmann; Darshan Doshi; David J Cohen; Augusto D Pichard; Samir Kapadia; Todd Dewey; Vasilis Babaliaros; Wilson Y Szeto; Mathew R Williams; Dean Kereiakes; Alan Zajarias; Kevin L Greason; Brian K Whisenant; Robert W Hodson; Jeffrey W Moses; Alfredo Trento; David L Brown; William F Fearon; Philippe Pibarot; Rebecca T Hahn; Wael A Jaber; William N Anderson; Maria C Alu; John G Webb
Journal:  N Engl J Med       Date:  2016-04-02       Impact factor: 91.245

View more
  1 in total

1.  The Presence of Calcified Raphe Is an Independent Predictor of Adverse Long-Term Clinical Outcomes in Patients With Bicuspid Aortic Stenosis Undergoing Transcatheter Aortic Valve Replacement.

Authors:  Yung-Tsai Lee; Wei-Hsian Yin; Tien-Ping Tsao; Kuo-Chen Lee; Ming-Chon Hsiung; Yun-Hsuan Tzeng; Jeng Wei
Journal:  Front Cardiovasc Med       Date:  2022-04-13
  1 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.