Rotational Stability and Visual Outcomes of V4c Toric Phakic Intraocular Lenses.

Hun Lee, David Sung Yong Kang, Jin Young Choi, Byoung Jin Ha, Eung Kweon Kim, Kyoung Yul Seo, Tae-Im Kim.   

Abstract

PURPOSE: To investigate the clinical outcomes and rotational stability following implantation of V4c toric implantable collamer lenses (ICLs) (STAAR Surgical Company, Monrovia, CA) and to analyze the factors that influence rotational stability.
METHODS: In this prospective observational case series, the authors analyzed the visual outcomes and rotational stability in 52 eyes of 52 patients immediately and 3 and 6 months after implantation. Postoperative rotation was defined as the angle between the adjusted axis and alignment axis. Central vaulting of the ICL was measured in a non-accommodative state using Visante optical coherence tomography (Carl Zeiss Meditec, Jena, Germany). Vector analysis of refractive astigmatism was performed. Regression analysis was used to investigate the association between the degree of rotation 6 months postoperatively and the associated variables.
RESULTS: The mean efficacy index and safety index 6 months postoperatively were 1.35 ± 0.19 and 1.38 ± 0.22, respectively. In vector analysis, the magnitude of error was -0.20 diopters (D), indicating slight undercorrection. Absolute degree of rotation was 2.81° ± 1.87° immediately after the operation and 3.75° ± 2.92° and 3.87° ± 3.07° at 3 and 6 months postoperatively, respectively (P = .009). Bonferroni-adjusted post-hoc comparison showed that the absolute degree of rotation immediately after the operation was significantly smaller than that after 3 (P = .043) and 6 (P = .023) months, with barely any change after 3 months. No explanatory variable relevant to the absolute degree of rotation was discovered.
CONCLUSIONS: The V4c toric ICL is predictable, safe, and effective in correcting low and high levels of astigmatism, showing relatively good postoperative rotational stability. [J Refract Surg. 2018;34(7):489-496.]. Copyright 2018, SLACK Incorporated.

Entities:  

Mesh:

Year:  2018        PMID: 30001453     DOI: 10.3928/1081597X-20180521-01

Source DB:  PubMed          Journal:  J Refract Surg        ISSN: 1081-597X            Impact factor:   3.573


  8 in total

1.  One-year follow-up of a new posterior chamber toric phakic intraocular lens implantation for moderate-to-high myopic astigmatism.

Authors:  M E Sucu; A Agca; B Tulu
Journal:  Int Ophthalmol       Date:  2021-04-20       Impact factor: 2.031

2.  Influence of Ocular Residual Astigmatism on the Correction of Myopic Astigmatism by Toric Implantable Collamer Lens: A Comparative Study With Femtosecond Laser Small Incision Lenticule Extraction.

Authors:  Ling Sun; Xiaoyu Zhang; Lan Ding; Yang Shen; Yishan Qian; Xingtao Zhou
Journal:  Front Med (Lausanne)       Date:  2022-06-13

3.  Polar value analysis of astigmatic change and rotational stability after implantation of V4c toric implantable collamer lens.

Authors:  Danyao Nie; Pisong Yan; Zonghui Yan; Jing Zhang; Wenling He; Ming Li; Liangnan Sun; Mingquan Huang; Xinhua Liu; Haotian Lin
Journal:  Ann Transl Med       Date:  2021-01

4.  Clinical Effect and Rotational Stability of TICL in the Treatment of Myopic Astigmatism.

Authors:  Manhui Zhu; Linling Zhu; Qiujian Zhu; Cailian Xu; Peng Yu; Haiyang Xiao; Ying Wang; You Yuan
Journal:  J Ophthalmol       Date:  2020-12-14       Impact factor: 1.909

5.  Safety and efficacy of toric implantable collamer lens V4c model - A retrospective South Indian study.

Authors:  S Ravi Chaitanya; Venugopal Anitha; Meenakshi Ravindran; Aditya Ghorpade; Ramakrishnan Rengappa; Mahammed Sithiq Uduman
Journal:  Indian J Ophthalmol       Date:  2020-12       Impact factor: 1.848

6.  Factors leading to realignment or exchange after implantable collamer lens implantation in 10 258 eyes.

Authors:  Ruoyan Wei; Meiyan Li; Aruma Aruma; Michael C Knorz; Dong Yang; Yongfu Yu; Xiaoying Wang; Joanne Choi; Peijun Yao; Xingtao Zhou
Journal:  J Cataract Refract Surg       Date:  2022-03-30       Impact factor: 3.528

7.  Assessment of low-vault cases with an implantable collamer lens.

Authors:  Sayaka Kato; Kimiya Shimizu; Akihito Igarashi
Journal:  PLoS One       Date:  2020-11-04       Impact factor: 3.240

8.  Safety of implantable Collamer lens implantation without ophthalmic viscosurgical device: A retrospective cohort study.

Authors:  Manqiang Peng; Qiongyan Tang; Libei Zhao; Muhanmad Ahmad Khan; Ding Lin
Journal:  Medicine (Baltimore)       Date:  2020-06-12       Impact factor: 1.817

  8 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.