Literature DB >> 30001451

Changes of Functional Optical Zone After LASIK for Hyperopia and Hyperopic Astigmatism.

Christian Roesler, Thomas Kohnen.   

Abstract

PURPOSE: To evaluate which factors may influence the size of the postoperative functional optical zone after hyperopic LASIK.
METHODS: Thirty-three eyes with a mean spherical equivalent of +3.55 ± 1.28 diopters (D) underwent LASIK with a Technolas 217 C-LASIK laser (Bausch & Lomb Surgical, Munich, Germany). After 1 week and 1, 4, and 12 months, the authors examined refraction, corneal refractive power by means of computerized videokeratography (Technomed C-Scan; Baesweiler, Germany), and uncorrected/corrected distance visual acuity (UDVA/CDVA). According to the degree of hyperopia, they were divided into low hyperopia (spherical equivalent ≤ 3.00 D) and high hyperopia (spherical equivalent > 3.00 D) groups.
RESULTS: One year postoperatively, 82% of all eyes had a UDVA of 0.5 or better; in 88%, the spherical equivalent did not deviate more than 1.00 D from the attempted value. Three eyes were slightly undercorrected. After an initial overcorrection (-0.27 D) with subsequent regression, the refraction remained stable at +0.17 D from the fourth postoperative month (low hyperopia group: +0.14 D; high hyperopia group: +0.19 D after 1 year). After 1 year, the functional optical zone diminished by 32%; the reduction was more pronounced in eyes with higher hyperopia: -1.85 ± 1.09 mm (range: +0.5 to -3.4 mm) in the low hyperopia group (P < .0001) and -2.25 ± 1.24 mm (range: +1 to -3.9 mm) in the high hyperopia group (P < .0001). Preoperative spherical equivalent and preoperative corneal refractive power affected the postoperative size of the functional optical zone additively.
CONCLUSIONS: An expected small functional optical zone in high hyperopia may not be regarded as a compelling exclusion criterion, but can induce possible side effects such as glare and halos. [J Refract Surg. 2018;34(7):476-481.]. Copyright 2018, SLACK Incorporated.

Entities:  

Mesh:

Year:  2018        PMID: 30001451     DOI: 10.3928/1081597X-20180515-03

Source DB:  PubMed          Journal:  J Refract Surg        ISSN: 1081-597X            Impact factor:   3.573


  2 in total

1.  [Corneal complications after PRK for hyperopia].

Authors:  Christoph Lwowski; Thomas Kohnen
Journal:  Ophthalmologe       Date:  2020-02       Impact factor: 1.059

2.  Femtosecond-LASIK outcomes using the VisuMax®-MEL® 80 platform for hyperopia and hyperopic astigmatism refractive surgery.

Authors:  Bogdana Tăbăcaru; Horia Tudor Stanca; Ruxandra Angela Pîrvulescu; Simona Stanca; Ciprian Danielescu; Mihnea Munteanu; Cosmin Roșca; Adrian Cosmin Teodoru
Journal:  Exp Ther Med       Date:  2021-01-26       Impact factor: 2.447

  2 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.