Literature DB >> 29998154

Letter to the Editor.

Tadaki Nakahara1.   

Abstract

Year:  2018        PMID: 29998154      PMCID: PMC6038965     

Source DB:  PubMed          Journal:  Asia Ocean J Nucl Med Biol        ISSN: 2322-5718


× No keyword cloud information.
We read with interest the article by Tsutsui et al. (Tsutsui Y, Awamoto S, Himuro K, Umezu Y, Baba S, Sasaki M.: Characteristics of Smoothing Filters to Achieve the Guideline Recommended Positron Emission Tomography Image without Harmonization. Asia Ocean J Nucl Med Biol. 2018 Winter; 6(1):15-23. doi: 10.22038/aojnmb.2017.26684.1186.) (1). However, we were really stunned by the absence of the citation of our recent work (2) regarding a technical approach for nuclear image harmonization. Although our study dealt with SPECT but not PET, we found two major common harmonization methodologies between our and their studies: (a) comparison of actual NEMA phantom image and digital reference object (DRO) developed by the Quantitative Imaging Biomarker Alliance (QIBA) FDG PET technical committee, and (b) use of the root mean squared error (RMSE) for evaluation of appropriate harmonization. The formula and figure of RMSE in their article were quite similar to ours. Of key importance, the use of the DRO was firstly published in 2015 (3), only analyzing calculation accuracy of PET standardized uptake value. Since then, to our knowledge, our study would be the first to show a harmonization procedure of nuclear image quantitation using the DRO. Given this, we believe that the authors should have cited our work.

Conflicts of interest

None declared.
  3 in total

1.  A Digital Reference Object to Analyze Calculation Accuracy of PET Standardized Uptake Value.

Authors:  Larry A Pierce; Brian F Elston; David A Clunie; Dennis Nelson; Paul E Kinahan
Journal:  Radiology       Date:  2015-05-19       Impact factor: 11.105

2.  Use of a digital phantom developed by QIBA for harmonizing SUVs obtained from the state-of-the-art SPECT/CT systems: a multicenter study.

Authors:  Tadaki Nakahara; Hiromitsu Daisaki; Yasushi Yamamoto; Takashi Iimori; Kazuyuki Miyagawa; Tomoya Okamoto; Yoshiki Owaki; Nobuhiro Yada; Koichi Sawada; Ryotaro Tokorodani; Masahiro Jinzaki
Journal:  EJNMMI Res       Date:  2017-06-20       Impact factor: 3.138

3.  Characteristics of Smoothing Filters to Achieve the Guideline Recommended Positron Emission Tomography Image without Harmonization.

Authors:  Yuji Tsutsui; Shinichi Awamoto; Kazuhiko Himuro; Yoshiyuki Umezu; Shingo Baba; Masayuki Sasaki
Journal:  Asia Ocean J Nucl Med Biol       Date:  2018
  3 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.