Literature DB >> 29995500

Liver MR Elastography at 3 T: Agreement Across Pulse Sequences and Effect of Liver R2* on Image Quality.

Ely R Felker1, Kang-Sun Choi2, Kyung Sung1, Holden H Wu1, Steven S Raman1, Bradley D Bolster3, Stephan Kannengiesser4, Kari Sorge1, David S K Lu1.   

Abstract

OBJECTIVE: The objectives of our study were to compare MR elastography (MRE) based on gradient-recalled echo (GRE) imaging with spin-echo echo-planar imaging (SEEPI) and rapid fractional (RF)-GRE MRE sequences at 3 T in terms of liver stiffness (LS) and image quality and to evaluate the effect of liver R2* on image quality.
MATERIALS AND METHODS: Eighty-one patients underwent 3-T liver MRE with GRE, SE-EPI, and RF-GRE sequences performed in variable order in this study. LS and ROI areas on the LS 95% confidence maps were compared among the three sequences. The relationship between liver R2* and ROI area was investigated.
RESULTS: There was no significant difference in mean LS among the three sequences (p = 0.49). Mean ROI area was significantly larger for RF-GRE (18,213 ± 9292 [SD] mm2) than for GRE (13,196 ± 8149 mm2) and SE-EPI (12,896 ± 8656 mm2) (p < 0.0001). Liver R2* was significantly higher among patients with one or more failed sequences (mean ± SD, 116 ± 76 s-1) than for patients with no failed sequences (59 ± 26 s-1) (p = 0.001). Technical failure rates were 10% (8/81), 4% (3/81), and 2% (2/81) for GRE, SE-EPI, and RF-GRE, respectively. Among patients with iron overload (R2* ≥ 100 s-1), there was a trend toward larger ROI area for SE-EPI (p = 0.09).
CONCLUSION: SE-EPI-and RF-GRE-based MRE sequences provide equivalent measures of LS compared with GRE-based MRE, and both have lower technical failure rates. The RF-GRE sequence yielded the largest measurable area of LS. Among patients with iron overload, there was a trend toward larger measurable area of LS for the SE-EPI sequence.

Entities:  

Keywords:  MR elastography; iron overload; liver; rapid fractional gradient-recalled echo (RF-GRE); spin-echo echo-planar imaging (SE-EPI)

Mesh:

Year:  2018        PMID: 29995500     DOI: 10.2214/AJR.17.19288

Source DB:  PubMed          Journal:  AJR Am J Roentgenol        ISSN: 0361-803X            Impact factor:   3.959


  9 in total

Review 1.  Advances in Magnetic Resonance Elastography of Liver.

Authors:  Jiahui Li; Sudhakar Kundapur Venkatesh; Meng Yin
Journal:  Magn Reson Imaging Clin N Am       Date:  2020-06-06       Impact factor: 2.266

2.  MR elastography of liver at 3 Tesla: comparison of gradient-recalled echo (GRE) and spin-echo (SE) echo-planar imaging (EPI) sequences and agreement across stiffness measurements.

Authors:  Chenyang Zhan; Stephan Kannengiesser; Hersh Chandarana; Matthias Fenchel; Justin Ream; Krishna Prasad Shanbhogue
Journal:  Abdom Radiol (NY)       Date:  2019-05

3.  Prospective comparison of transient, point shear wave, and magnetic resonance elastography for staging liver fibrosis.

Authors:  Thierry Lefebvre; Claire Wartelle-Bladou; Philip Wong; Giada Sebastiani; Jeanne-Marie Giard; Hélène Castel; Jessica Murphy-Lavallée; Damien Olivié; André Ilinca; Marie-Pierre Sylvestre; Guillaume Gilbert; Zu-Hua Gao; Bich N Nguyen; Guy Cloutier; An Tang
Journal:  Eur Radiol       Date:  2019-07-05       Impact factor: 5.315

4.  Quality Control of Magnetic Resonance Elastography Using Percent Measurable Liver Volume Estimation.

Authors:  David H Ballard; Daniel R Ludwig; Tyler J Fraum; Amber Salter; Vamsi R Narra; Anup S Shetty
Journal:  J Magn Reson Imaging       Date:  2021-10-27       Impact factor: 5.119

5.  Magnetic resonance elastography SE-EPI vs GRE sequences at 3T in a pediatric population with liver disease.

Authors:  Juan S Calle-Toro; Suraj D Serai; Erum A Hartung; David J Goldberg; Bradley D Bolster; Kassa Darge; Sudha A Anupindi
Journal:  Abdom Radiol (NY)       Date:  2019-03

6.  Assessment of SE-MRE-derived shear stiffness at 3.0 Tesla for solid liver tumors characterization.

Authors:  Andrés Dominguez; Daniel Fino; Juan Carlos Spina; Nicolas Moyano Brandi; Joaquín Capó; Maximiliano Noceti; Pedro Pablo Ariza; Guilherme Moura Cunha
Journal:  Abdom Radiol (NY)       Date:  2020-10-24

7.  Imaging Biomarkers of Hepatic Fibrosis: Reliability and Accuracy of Hepatic Periportal Space Widening and Other Morphologic Features on MRI.

Authors:  Daniel R Ludwig; Tyler J Fraum; David H Ballard; Vamsi R Narra; Anup S Shetty
Journal:  AJR Am J Roentgenol       Date:  2021-03-17       Impact factor: 3.959

8.  Free-breathing radial magnetic resonance elastography of the liver in children at 3 T: a pilot study.

Authors:  Sevgi Gokce Kafali; Tess Armstrong; Shu-Fu Shih; Grace J Kim; Joseph L Holtrop; Robert S Venick; Shahnaz Ghahremani; Bradley D Bolster; Claudia M Hillenbrand; Kara L Calkins; Holden H Wu
Journal:  Pediatr Radiol       Date:  2022-04-02

9.  Abdominal magnetic resonance imaging examination of Tibetan patients with abnormal iron metabolism and a preliminary study of correlations with blood cell analysis.

Authors:  Yi Zhou; Jin-Li Meng; Li Feng; Yong-Hong Huang; Jin Ye; Man Li; Zhong-You Xu; Xiang-Wei Li; Fang Yuan; Bin Song
Journal:  J Int Med Res       Date:  2020-03       Impact factor: 1.671

  9 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.