Literature DB >> 29993537

NOVIFAST: A Fast Algorithm for Accurate and Precise VFA MRI Mapping.

Gabriel Ramos-Llorden, Gonzalo Vegas-Sanchez-Ferrero, Marcus Bjork, Floris Vanhevel, Paul M Parizel, Raul San Jose Estepar, Arnold J den Dekker, Jan Sijbers.   

Abstract

In quantitative magnetic resonance mapping, the variable flip angle (VFA) steady state spoiled gradient recalled echo (SPGR) imaging technique is popular as it provides a series of high resolution weighted images in a clinically feasible time. Fast, linear methods that estimate maps from these weighted images have been proposed, such as DESPOT1 and iterative re-weighted linear least squares. More accurate, non-linear least squares (NLLS) estimators are in play, but these are generally much slower and require careful initialization. In this paper, we present NOVIFAST, a novel NLLS-based algorithm specifically tailored to VFA SPGR mapping. By exploiting the particular structure of the SPGR model, a computationally efficient, yet accurate and precise map estimator is derived. Simulation and in vivo human brain experiments demonstrate a twenty-fold speed gain of NOVIFAST compared with conventional gradient-based NLLS estimators while maintaining a high precision and accuracy. Moreover, NOVIFAST is eight times faster than the efficient implementations of the variable projection (VARPRO) method. Furthermore, NOVIFAST is shown to be robust against initialization.

Entities:  

Mesh:

Year:  2018        PMID: 29993537      PMCID: PMC6277233          DOI: 10.1109/TMI.2018.2833288

Source DB:  PubMed          Journal:  IEEE Trans Med Imaging        ISSN: 0278-0062            Impact factor:   10.048


  32 in total

1.  Adaptive reconstruction of phased array MR imagery.

Authors:  D O Walsh; A F Gmitro; M W Marcellin
Journal:  Magn Reson Med       Date:  2000-05       Impact factor: 4.668

2.  Generalized autocalibrating partially parallel acquisitions (GRAPPA).

Authors:  Mark A Griswold; Peter M Jakob; Robin M Heidemann; Mathias Nittka; Vladimir Jellus; Jianmin Wang; Berthold Kiefer; Axel Haase
Journal:  Magn Reson Med       Date:  2002-06       Impact factor: 4.668

3.  Efficient and reliable schemes for nonlinear diffusion filtering.

Authors:  J Weickert; B H Romeny; M A Viergever
Journal:  IEEE Trans Image Process       Date:  1998       Impact factor: 10.856

4.  Maximum-likelihood estimation of Rician distribution parameters.

Authors:  J Sijbers; A J den Dekker; P Scheunders; D Van Dyck
Journal:  IEEE Trans Med Imaging       Date:  1998-06       Impact factor: 10.048

5.  Variable flip angle T1 mapping in the human brain with reduced T2 sensitivity using fast radiofrequency-spoiled gradient echo imaging.

Authors:  Rahel Heule; Carl Ganter; Oliver Bieri
Journal:  Magn Reson Med       Date:  2015-05-15       Impact factor: 4.668

6.  Visualizing samples with box plots.

Authors:  Martin Krzywinski; Naomi Altman
Journal:  Nat Methods       Date:  2014-02       Impact factor: 28.547

7.  Rapid simultaneous high-resolution mapping of myelin water fraction and relaxation times in human brain using BMC-mcDESPOT.

Authors:  Mustapha Bouhrara; Richard G Spencer
Journal:  Neuroimage       Date:  2016-10-08       Impact factor: 6.556

8.  Linear least-squares method for unbiased estimation of T1 from SPGR signals.

Authors:  Lin-Ching Chang; Cheng Guan Koay; Peter J Basser; Carlo Pierpaoli
Journal:  Magn Reson Med       Date:  2008-08       Impact factor: 4.668

9.  Assessment of demyelination, edema, and gliosis by in vivo determination of T1 and T2 in the brain of patients with acute attack of multiple sclerosis.

Authors:  H B Larsson; J Frederiksen; J Petersen; A Nordenbo; I Zeeberg; O Henriksen; J Olesen
Journal:  Magn Reson Med       Date:  1989-09       Impact factor: 4.668

10.  Joint system relaxometry (JSR) and Crámer-Rao lower bound optimization of sequence parameters: A framework for enhanced precision of DESPOT T1 and T2 estimation.

Authors:  Rui Pedro A G Teixeira; Shaihan J Malik; Joseph V Hajnal
Journal:  Magn Reson Med       Date:  2017-03-16       Impact factor: 4.668

View more
  3 in total

1.  A Generalized Mechanistic Model for Assessing and Forecasting the Spread of the COVID-19 Pandemic.

Authors:  Hamdi Friji; Raby Hamadi; Hakim Ghazzai; Hichem Besbes; Yehia Massoud
Journal:  IEEE Access       Date:  2021-01-18       Impact factor: 3.367

2.  Comparing the signal enhancement of a gadolinium based and an iron-oxide based contrast agent in low-field MRI.

Authors:  Jordy K van Zandwijk; Frank F J Simonis; Friso G Heslinga; Elfi I S Hofmeijer; Robert H Geelkerken; Bennie Ten Haken
Journal:  PLoS One       Date:  2021-08-17       Impact factor: 3.240

3.  Automatic classification of tissues on pelvic MRI based on relaxation times and support vector machine.

Authors:  Jorge Arturo Zavala Bojorquez; Pierre-Marc Jodoin; Stéphanie Bricq; Paul Michael Walker; François Brunotte; Alain Lalande
Journal:  PLoS One       Date:  2019-02-22       Impact factor: 3.240

  3 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.